Canada

Thermo Fisher Scientific operating as Unity Lab Services

Ottawa, Canada

Visit website
A2LA 4946.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 4946.01 · 17 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 1 of 16 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 THERMO FISHER SCIENTIFIC operating as UNITY LAB SERVICES 4 112 Colonnade Rd Ottawa, ON, CANADA K2E 7L6 Martin Legault Phone: 613 796-1394 CALIBRATION Valid to: April 30, 2027 Certificate Number: 4946.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Chemical Quantities Parameter/Equipment Range CMC 2, 6 (±) Comments CO₂ – Measure & Measuring Equipment Up to 20 % CO 2 1.0 % CO₂ Certified gas analyzer II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2 (±) Comments Electrical Calibration of pH Meters 3 pH: 14 13 12 11 10 9 8 7 -414.12 mV DC -354.96 mV DC -295.80 mV DC -236.64 mV DC -177.48 mV DC -118.32 mV DC -59.16 mV DC 0.00 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC Using the Nerst equation giving 59.16 mV/pH at 25 °C with the isopotential point at 7.00 pH
to 20 % CO₂
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 2 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of pH Meters 3 (cont) pH: 6 5 4 3 2 1 0 59.16 mV DC 118.32 mV DC 177.48 mV DC 236.64 mV DC 295.80 mV DC 354.96 mV DC 414.12 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC 0.17 mV DC Using the Nerst equation giving 59.16 mV/pH at 25 °C with the isopotential point at 7.00 pH Parameter/Range Frequency CMC2, 7 (±) Comments AC Volts – Generate 4 (1.0 to 32.999) mV (33 to 329.999) mV (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.030 % + 8 µV 0.015 % + 8 µV 0.016 % + 8 µV 0.035 % + 8 µV 0.080 % + 32 µV 0.20 % + 70 µV 0.030 % + 50 µV 0.015 % + 60 µV 0.019 % + 60 µV 0.030 % + 50 µV 0.070 % + 130 µV Fluke 5522A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 3 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Volts – Generate 4 (cont) (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) (300 to 1020) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz (45 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (45 to 1000) Hz (1 to 5) kHz (5 to 10) kHz 0.030 % + 0.65 mV 0.015 % + 0.60 mV 0.024 % + 0.60 mV 0.035 % + 0.60 mV 0.090 % + 1.6 mV 0.030 % + 0.65 mV 0.015 % + 0.60 mV 0.024 % + 0.60 mV 0.035 % + 0.60 mV 0.090 % + 1.6 mV 0.019 % + 2.0 mV 0.020 % + 6.0 mV 0.025 % + 6.0 mV 0.030 % + 6.0 mV 0.20 % + 50 mV 0.030 % + 10 mV 0.025 % + 10 mV 0.030 % + 10 mV Fluke 5522A AC Volts – Measure4 (0 to 100) mV (0.1 to 1) V (3 to 5) Hz (5 to 10) Hz (0.01 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 1.0 % + 0.04 mV 0.35 % + 0.04 mV 0.06 % + 0.04 mV 0.12 % + 0.05 mV 0.6 % + 0.08 mV 4.0 % + 0.05 mV 1.0 % + 0.0003 V 0.35 % + 0.0003 V 0.06 % + 0.0003 V 0.12 % + 0.0005 V 0.60 % + 0.0008 V 4.0 % + 0.005 V Fluke 8846A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 4 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Volts – Measure 4 (cont) (1 to 10) V (10 to 100) V (100 to 1000) V (3 to 5) Hz (5 to 10) Hz (0.01 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 1.0 % + 0.003 V 0.35 % + 0.003 V 0.06 % + 0.003 V 0.12 % + 0.005 V 0.60 % + 0.008 V 4.0 % + 0.05 V 1.0 % + 0.03 V 0.35 % + 0.03 V 0.06 % + 0.03 V 0.12 % + 0.05 V 0.60 % + 0.08 V 4.0 % + 0.5 V 1.0 % + 0.23 V 0.35 % + 0.23 V 0.06 % + 0.23 V 0.12 % + 0.38 V 0.6 % + 0.6 V 4.0 % + 3.8 V Fluke 8846A Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate 4 (0 to 329.9999) mV (0.329 to 3.299 999) V (3.29 to 32.999 99) V (32.9 to 329.9999) V (329 to 1020.000) V 0.0023 % + 2.0 µV 0.0013 % + 3.5 µV 0.0014 % + 35 µV 0.0021 % + 250 µV 0.0021 % + 1.8 mV Fluke 5522A DC Volts – Measure 4 (0 to 100) mV (0.001 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.0037 % + 0.0035 mV 0.0025 % + 0.000 007 V 0.0024 % + 0.000 05 V 0.0038 % + 0.0006 V 0.0041 % + 0.01 V Fluke 8846A
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 5 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Resistance – Generate 4 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.999 99) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 0.0040 % + 0.01 Ω 0.0030 % + 0.015 Ω 0.0028 % + 0.015 Ω 0.0028 % + 0.02 Ω 0.0028 % + 0.02 Ω 0.0028 % + 0.20 Ω 0.0028 % + 0.1 Ω 0.0028 % + 1.0 Ω 0.0028 % + 1.0 Ω 0.0032 % + 10 Ω 0.0032 % + 10 Ω 0.0060 % + 150 Ω 0.013 % + 250 Ω 0.025 % + 2.5 kΩ 0.050 % + 3.0 kΩ 0.30 % + 100 kΩ 1.5 % + 500 kΩ Fluke 5522A Resistance – Measure 4 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 0.01 % + 0.003 Ω 0.01 % + 0.004 Ω 0.01 % + 0.000 01 kΩ 0.01 % + 0.0001 kΩ 0.01 % + 0.001 kΩ 0.01 % + 0.000 01 MΩ 0.04 % + 0.0001 MΩ 0.8 % + 0.01 MΩ 2.0 % + 0.0001 GΩ Fluke 8846A Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate4 (29.00 to 329.99) µA (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.20 % + 0.10 µA 0.15 % + 0.10 µA 0.13 % + 0.10 µA 0.30 % + 0.15 µA 0.80 % + 0.20 µA 1.6 % + 0.40 µA Fluke 5522A
to 1100 MΩ
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 6 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate4 (cont) (0.33 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 o 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz 0.20 % + 0.15 µA 0.13 % + 0.15 µA 0.10 % + 0.15 µA 0.20 % + 0.20 µA 0.50 % + 0.30 µA 1.0 % + 0.60 µA 0.16 % + 2.0 µA 0.09 % + 2.0 µA 0.04 % + 2.0 µA 0.08 % + 2.0 µA 0.20 % + 3.0 µA 0.40 % + 4.0 µA 0.10 % + 20 µA 0.090 % + 20 µA 0.040 % + 20 µA 0.10 % + 50 µA 0.20 % + 100 µA 0.40 % + 200 µA 0.18 % + 0.10 mA 0.050 % + 0.10 mA 0.60 % + 1.0 mA 2.5 % + 5.0 mA 0.18 % + 0.10 mA 0.060 % + 0.10 mA 0.60 % + 1.0 mA 2.5 % + 5.0 mA 0.060 % + 2.0 mA 0.10 % + 2.0 mA 3.0 % + 2.0 mA 0.12 % + 5.0 mA 0.15 % + 5.0 mA 3.0 % + 5.0 mA Fluke 5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Measure 4 (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (100 to 400) mA (0.4 to 1) A (1 to 3) A (3 to 10) A (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz (3 to 5) Hz (5 to 10) Hz (0.01 to 5) kHz (5 to 10) kHz 1.0 % + 0.06 µA 0.35 % + 0.06 µA 0.15 % + 0.06 µA 0.35 % + 0.70 µA 1.0 % + 0.0004 mA 0.3 % + 0.0004 mA 0.1 % + 0.0004 mA 0.2 % + 0.0025 mA 1.1 % + 0.006 mA 0.35 % + 0.006 mA 0.15 % + 0.006 mA 0.35 % + 0.07 mA 1.0 % + 0.04 mA 0.3 % + 0.4 mA 0.1 % + 0.4 mA 0.2 % + 0.25 mA 1.0 % + 0.4 mA 0.3 % + 0.4 mA 0.1 % + 0.4 mA 0.2 % + 2.8 mA 1.0 % + 0.0004 A 0.3 % + 0.0004 A 0.1 % + 0.0004 A 0.35 % + 0.007 A 1.1 % + 0.0018 A 0.35 % + 0.0018 A 0.15 % + 0.0018 A 0.35 % + 0.021 A 1.1 % + 0.006 A 0.35 % + 0.006 A 0.15 % + 0.006 A 0.35 % + 0.07 A Fluke 8846A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 8 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current – Generate 4 (0 to 329.999) µA (0.3 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.3 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A 0.015 % + 0.020 µA 0.010 % + 0.05 µA 0.010 % + 0.25 µA 0.010 % + 2.5 µA 0.020 % + 40 µA 0.038 % + 40 µA 0.050 % + 500 µA 0.10 % + 750 µA Fluke 5522A DC Current – Measure 4 (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (100 to 400) mA (0.4 to 1) A (1 to 3) A (3 to 10) A 0.05 % + 0.025 µA 0.05 % + 0.000 05 mA 0.05 % + 0.002 mA 0.05 % + 0.005 mA 0.05 % + 0.02 mA 0.05 % + 0.0002 A 0.1 % + 0.0006 A 0.15 % + 0.0008 A Fluke 8846A Capacitance – Generate 4 (220 to 339.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.50 % + 10 pF 0.50 % + 0.01 nF 0.50 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.01 nF 0.25 % + 0.03 nF 0.25 % + 1.0 nF 0.25 % + 3.0 nF 0.25 % + 10 nF 0.40 % + 30 nF 0.45 % + 100 nF 0.45 % + 300 nF 0.45 % + 1.0 µF 0.45 % + 3.0 µF 0.45 % + 10 µF 0.75 % + 30 µF 1.1 % + 100 µF Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 9 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance – Measure 4 (0 to 1) nF (1 to 10) nF (10 to 100) nF (0.1 to 1) µF (1 to 10) µF (10 to 100) µF (0.1 to 1) mF (1 to 10) mF (10 to 100) mF 2.0 % + 0.025 nF 1.0 % + 0.05 nF 1.0 % + 0.5 nF 1.0 % + 0.005 µF 1.0 % + 0.05 µF 1.0 % + 0.5 µF 1.0 % + 0.005 mF 1.0 % + 0.05 mF 4.0 % + 0.2 mF Fluke 8846A Thermocouple – Generate Type E Type J Type K Type N Type R Type S (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 750) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120 °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (120 to 400) °C 0.50 °C 0.16 °C 0.14 °C 0.16 °C 0.21 °C 0.27 °C 0.16 °C 0.14 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.16 °C 0.26 °C 0.40 °C 0.40 °C 0.22 °C 0.19 °C 0.18 °C 0.27 °C 0.57 °C 0.35 °C 0.33 °C 0.40 °C 0.47 °C 0.36 °C 0.37 °C 0.46 °C 0.14 °C Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 10 of 16 Parameter/Equipment Range CMC2 (±) Comments Thermocouple – Generate (cont) Type T (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.63 °C 0.37 °C 0.16 °C 0.14 °C Fluke 5522A RTD – Generate Pt 385 – 100 Ω Pt 3926 – 100 Ω Pt 3916 – 100 Ω Pt 3985 – 200 Ω (-200 to -80) °C (-80 to 0 °C) (0 to 100 °C) (100 to 300) °C (300 to 400) °C (400 to 640) °C (640 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 640) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.050 °C 0.050 °C 0.070 °C 0.090 °C 0.10 °C 0.12 °C 0.23 °C 0.050 °C 0.050 °C 0.070 °C 0.090 °C 0.10 °C 0.12 °C 0.25 °C 0.040 °C 0.050 °C 0.060 °C 0.070 °C 0.080 °C 0.090 °C 0.10 °C 0.23 °C 0.040 °C 0.040 °C 0.040 °C 0.050 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C Fluke 5522A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 11 of 16 III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Mass – Fixed Points 1 mg 2 mg 3 mg 5 mg 10 mg 20 mg 30 mg 50 mg 100 mg 200 mg 300 mg 500 mg 1 g 2 g 3 g 5 g 10 g 20 g 30 g 50 g 100 g 200 g 300 g 500 g 1 kg 2 kg 3 kg 5 kg 10 kg 20 kg 25 kg 585 g 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0020 mg 0.0030 mg 0.0040 mg 0.0068 mg 0.0068 mg 0.008 mg 0.010 mg 0.017 mg 0.033 mg 0.050 mg 0.040 mg 0.080 mg 0.10 mg 0.15 mg 0.24 mg 0.5 mg 1.0 mg 1.5 mg 2.4 mg 9.6 mg 20 mg 30 mg 0.050 mg CMC relates to calibration of integral conventional standard weights
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 12 of 16 Parameter/Equipment Range CMC2 (±) Comments Mass (cont) (1 to 200) mg (>200 to 300) mg (>300 to 500) mg >500 mg to 2 g (>2 to 3) g (>3 to 5) g (>5 to 10) g (>10 to 20) g (>20 to 30) g (>30 to 50) g (>50 to 100) g (>100 to 200) g (>200 to 300) g (>300 to 500) g >500 g to 1 kg (>1 to 2) kg (>2 to 3) kg (>3 to 5) kg (>5 to 10) kg (>10 to 20) kg (>20 to 25) kg 0.0020 mg 0.0030 mg 0.0040 mg 0.0068 mg 0.0080 mg 0.010 mg 0.017 mg 0.033 mg 0.050 mg 0.040 mg 0.080 mg 0.10 mg 0.15 mg 0.24 mg 0.50 mg 1.0 mg 1.5 mg 2.4 mg 9.6 mg 20 mg 30 mg CMC relates to calibration of integral conventional standard weights Balances (Electronic, Non-automatic) 3 Up to 200 mg (>200 to 500) mg >500 mg to 2 g (>2 to 5) g (>5 to 10) g (>10 to 20) g (>20 to 50) g (>50 to 100) g (>100 to 200) g (>200 to 500) g >500 g to 1 kg (>1 to 2) kg (>2 to 5) kg (>5 to 10) kg (>10 to 30) kg 0.0025 mg 0.0045 mg 0.0070 mg 0.015 mg 0.020 mg 0.035 mg 0.075 mg 0.15 mg 0.20 mg 0.60 mg 3.0 mg 5.0 mg 10 mg 30 mg 270 mg Class 1 weights Centrifuges 3 (1000 to 15 000) rpm (>15 000 to 80 000) rpm 10 rpm 43 rpm Optical tachometer
13Gravimetric Method-See scope document
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 14 of 16 Parameter/Equipment Range CMC2 (±) Comments Spectrophotometers – Wavelength Peak Position 3 (279, 287, 360) nm (445, 453, 460) nm 536 nm 0.7 nm 0.7 nm 1.0 nm Holmium oxide filters V. Thermodynamics Parameter/Equipment Range CMC 2, 6 (±) Comments Temperature – Measure 3 (-80 to 105) °C (>105 to 150) °C (>150 to 200) °C (>200 to 250) °C (>250 to 300) °C (>300 to 350 °C (>350 to 450) °C (>450 to 1000) °C 0.13 °C 1 °C 2 °C 5 °C 7 °C 10 °C 12 °C 17 °C Reference Thermometer Temperature – IR Systems (-15 to 0) °C (>0 to 50) °C (>50 to 100) °C (>100 to 200) °C (>200 to 350) °C (>350 to 500) °C 0.31 °C 0.22 °C 0.25 °C 0.32 °C 0.56 °C 0.96 °C Blackbody IR calibrator Thermocouple Thermometer System -196 °C (-80 to 125) °C (125 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1200) °C 0.35 °C 0.21 °C 0.30 °C 0.90 °C 1.4 °C 2.3 °C Liquid bath or dry block calibrator Liquid-In-Glass Thermometers (Partial & Total Immersion) 3 (-45 to 145) °C 0.020 °C Liquid temperature bath
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 15 of 16 Parameter/Equipment Range CMC2, 6 (±) Comments Platinum Resistance Thermometer System 3 Fixed Point -196 °C (-80 to 125) °C (>126 to 400) °C (>401 to 600) °C 0.0073 °C 0.014 °C 0.15 °C 0.69 °C LN2 Cell w/SPRT Liquid bath or dry block calibrator Thermistor Thermometer System 3 (-10 to 105) °C 0.067 °C Stirred liquid bath Relative Humidity – Hygrometer Systems (10 to 35) % RH (35 to 65) % RH (65 to 95) % RH 95 % RH 0.23 % RH 0.43 % RH 0.55 % RH 0.76 % RH Rotronic Hygrogen H2-S Relative Humidity – Measure Up to 95 % RH 2.8 % RH Reference hygrometer VI. Time & Frequency Parameter/Equipment Range CMC 2, 6 (±) Comments Frequency – Measure, Up to 1000 V (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz (0.04 to 300) kHz (0.3 to 1) MHz 0.1 % Hz 0.05 % Hz 0.03 % Hz 0.01 % kHz 0.01 % MHz Fluke 8846A Timers3 (1 to 24) hr 0.013 s/day Timometer Optical Tachometers (0 to 1000) RPM (1000 to 10 000) RPM (10 000 to 25 000) RPM (25 000 to 100 000) RPM 0.15 RPM 0.20 RPM 0.65 RPM 1.5 RPM Function generator & lamp ___________________ 1 This laboratory offers commercial calibration services and field calibration services.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 16 of 16 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Offices for administration of field technicians are located in 145 Renfrew Dr, Markham, Ontario, Canada; 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
17

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited THERMO FISHER SCIENTIFIC operating as UNITY LAB SERVICES Ottawa, CANADA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 29TH day of April 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4946.01 Valid to April 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.