Thermo Fisher Scientific operating as Unity Lab Services
Ottawa, Canada
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Sites in our directory
- 3
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 4946.01 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 1 of 16
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
THERMO FISHER SCIENTIFIC operating as UNITY LAB SERVICES
4
112 Colonnade Rd
Ottawa, ON, CANADA K2E 7L6
Martin Legault Phone: 613 796-1394
CALIBRATION
Valid to: April 30, 2027 Certificate Number: 4946.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Chemical Quantities
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments
CO₂ – Measure &
Measuring Equipment
Up to 20 % CO
2
1.0 % CO₂
Certified gas analyzer
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2 (±)
Comments
Electrical Calibration of
pH Meters
3
pH:
14
13
12
11
10
9
8
7
-414.12 mV DC
-354.96 mV DC
-295.80 mV DC
-236.64 mV DC
-177.48 mV DC
-118.32 mV DC
-59.16 mV DC
0.00 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
Using the Nerst
equation giving 59.16
mV/pH at 25 °C with
the isopotential point
at 7.00 pH | to 20 % CO₂ |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 2 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
pH Meters
3 (cont)
pH:
6
5
4
3
2
1
0
59.16 mV DC
118.32 mV DC
177.48 mV DC
236.64 mV DC
295.80 mV DC
354.96 mV DC
414.12 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
0.17 mV DC
Using the Nerst
equation giving 59.16
mV/pH at 25 °C with
the isopotential point
at 7.00 pH
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Volts – Generate
4
(1.0 to 32.999) mV
(33 to 329.999) mV
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.030 % + 8 µV
0.015 % + 8 µV
0.016 % + 8 µV
0.035 % + 8 µV
0.080 % + 32 µV
0.20 % + 70 µV
0.030 % + 50 µV
0.015 % + 60 µV
0.019 % + 60 µV
0.030 % + 50 µV
0.070 % + 130 µV
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 3 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Volts – Generate
4
(cont)
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999)
(300 to 1020) V
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
(45 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
0.030 % + 0.65 mV
0.015 % + 0.60 mV
0.024 % + 0.60 mV
0.035 % + 0.60 mV
0.090 % + 1.6 mV
0.030 % + 0.65 mV
0.015 % + 0.60 mV
0.024 % + 0.60 mV
0.035 % + 0.60 mV
0.090 % + 1.6 mV
0.019 % + 2.0 mV
0.020 % + 6.0 mV
0.025 % + 6.0 mV
0.030 % + 6.0 mV
0.20 % + 50 mV
0.030 % + 10 mV
0.025 % + 10 mV
0.030 % + 10 mV
Fluke 5522A
AC Volts – Measure4
(0 to 100) mV
(0.1 to 1) V
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
1.0 % + 0.04 mV
0.35 % + 0.04 mV
0.06 % + 0.04 mV
0.12 % + 0.05 mV
0.6 % + 0.08 mV
4.0 % + 0.05 mV
1.0 % + 0.0003 V
0.35 % + 0.0003 V
0.06 % + 0.0003 V
0.12 % + 0.0005 V
0.60 % + 0.0008 V
4.0 % + 0.005 V
Fluke 8846A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 4 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Volts – Measure
4
(cont)
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
1.0 % + 0.003 V
0.35 % + 0.003 V
0.06 % + 0.003 V
0.12 % + 0.005 V
0.60 % + 0.008 V
4.0 % + 0.05 V
1.0 % + 0.03 V
0.35 % + 0.03 V
0.06 % + 0.03 V
0.12 % + 0.05 V
0.60 % + 0.08 V
4.0 % + 0.5 V
1.0 % + 0.23 V
0.35 % + 0.23 V
0.06 % + 0.23 V
0.12 % + 0.38 V
0.6 % + 0.6 V
4.0 % + 3.8 V
Fluke 8846A
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Voltage – Generate
4
(0 to 329.9999) mV
(0.329 to 3.299 999) V
(3.29 to 32.999 99) V
(32.9 to 329.9999) V
(329 to 1020.000) V
0.0023 % + 2.0 µV
0.0013 % + 3.5 µV
0.0014 % + 35 µV
0.0021 % + 250 µV
0.0021 % + 1.8 mV
Fluke 5522A
DC Volts – Measure
4
(0 to 100) mV
(0.001 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.0037 % + 0.0035 mV
0.0025 % + 0.000 007 V
0.0024 % + 0.000 05 V
0.0038 % + 0.0006 V
0.0041 % + 0.01 V
Fluke 8846A | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 5 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance – Generate
4
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.999 99) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
0.0040 % + 0.01 Ω
0.0030 % + 0.015 Ω
0.0028 % + 0.015 Ω
0.0028 % + 0.02 Ω
0.0028 % + 0.02 Ω
0.0028 % + 0.20 Ω
0.0028 % + 0.1 Ω
0.0028 % + 1.0 Ω
0.0028 % + 1.0 Ω
0.0032 % + 10 Ω
0.0032 % + 10 Ω
0.0060 % + 150 Ω
0.013 % + 250 Ω
0.025 % + 2.5 kΩ
0.050 % + 3.0 kΩ
0.30 % + 100 kΩ
1.5 % + 500 kΩ
Fluke 5522A
Resistance – Measure
4
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
0.01 % + 0.003 Ω
0.01 % + 0.004 Ω
0.01 % + 0.000 01 kΩ
0.01 % + 0.0001 kΩ
0.01 % + 0.001 kΩ
0.01 % + 0.000 01 MΩ
0.04 % + 0.0001 MΩ
0.8 % + 0.01 MΩ
2.0 % + 0.0001 GΩ
Fluke 8846A
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate4
(29.00 to 329.99) µA
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.20 % + 0.10 µA
0.15 % + 0.10 µA
0.13 % + 0.10 µA
0.30 % + 0.15 µA
0.80 % + 0.20 µA
1.6 % + 0.40 µA
Fluke 5522A | to 1100 MΩ |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 6 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Generate4
(cont)
(0.33 to 3.299 99) mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
(0.33 o 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
0.20 % + 0.15 µA
0.13 % + 0.15 µA
0.10 % + 0.15 µA
0.20 % + 0.20 µA
0.50 % + 0.30 µA
1.0 % + 0.60 µA
0.16 % + 2.0 µA
0.09 % + 2.0 µA
0.04 % + 2.0 µA
0.08 % + 2.0 µA
0.20 % + 3.0 µA
0.40 % + 4.0 µA
0.10 % + 20 µA
0.090 % + 20 µA
0.040 % + 20 µA
0.10 % + 50 µA
0.20 % + 100 µA
0.40 % + 200 µA
0.18 % + 0.10 mA
0.050 % + 0.10 mA
0.60 % + 1.0 mA
2.5 % + 5.0 mA
0.18 % + 0.10 mA
0.060 % + 0.10 mA
0.60 % + 1.0 mA
2.5 % + 5.0 mA
0.060 % + 2.0 mA
0.10 % + 2.0 mA
3.0 % + 2.0 mA
0.12 % + 5.0 mA
0.15 % + 5.0 mA
3.0 % + 5.0 mA
Fluke 5522A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 7 of 16
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current – Measure
4
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(100 to 400) mA
(0.4 to 1) A
(1 to 3) A
(3 to 10) A
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
(3 to 5) Hz
(5 to 10) Hz
(0.01 to 5) kHz
(5 to 10) kHz
1.0 % + 0.06 µA
0.35 % + 0.06 µA
0.15 % + 0.06 µA
0.35 % + 0.70 µA
1.0 % + 0.0004 mA
0.3 % + 0.0004 mA
0.1 % + 0.0004 mA
0.2 % + 0.0025 mA
1.1 % + 0.006 mA
0.35 % + 0.006 mA
0.15 % + 0.006 mA
0.35 % + 0.07 mA
1.0 % + 0.04 mA
0.3 % + 0.4 mA
0.1 % + 0.4 mA
0.2 % + 0.25 mA
1.0 % + 0.4 mA
0.3 % + 0.4 mA
0.1 % + 0.4 mA
0.2 % + 2.8 mA
1.0 % + 0.0004 A
0.3 % + 0.0004 A
0.1 % + 0.0004 A
0.35 % + 0.007 A
1.1 % + 0.0018 A
0.35 % + 0.0018 A
0.15 % + 0.0018 A
0.35 % + 0.021 A
1.1 % + 0.006 A
0.35 % + 0.006 A
0.15 % + 0.006 A
0.35 % + 0.07 A
Fluke 8846A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 8 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current – Generate
4
(0 to 329.999) µA
(0.3 to 3.299 99) mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
(0.3 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
0.015 % + 0.020 µA
0.010 % + 0.05 µA
0.010 % + 0.25 µA
0.010 % + 2.5 µA
0.020 % + 40 µA
0.038 % + 40 µA
0.050 % + 500 µA
0.10 % + 750 µA
Fluke 5522A
DC Current – Measure
4
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(100 to 400) mA
(0.4 to 1) A
(1 to 3) A
(3 to 10) A
0.05 % + 0.025 µA
0.05 % + 0.000 05 mA
0.05 % + 0.002 mA
0.05 % + 0.005 mA
0.05 % + 0.02 mA
0.05 % + 0.0002 A
0.1 % + 0.0006 A
0.15 % + 0.0008 A
Fluke 8846A
Capacitance – Generate
4
(220 to 339.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.50 % + 10 pF
0.50 % + 0.01 nF
0.50 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.01 nF
0.25 % + 0.03 nF
0.25 % + 1.0 nF
0.25 % + 3.0 nF
0.25 % + 10 nF
0.40 % + 30 nF
0.45 % + 100 nF
0.45 % + 300 nF
0.45 % + 1.0 µF
0.45 % + 3.0 µF
0.45 % + 10 µF
0.75 % + 30 µF
1.1 % + 100 µF
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 9 of 16
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Capacitance – Measure
4
(0 to 1) nF
(1 to 10) nF
(10 to 100) nF
(0.1 to 1) µF
(1 to 10) µF
(10 to 100) µF
(0.1 to 1) mF
(1 to 10) mF
(10 to 100) mF
2.0 % + 0.025 nF
1.0 % + 0.05 nF
1.0 % + 0.5 nF
1.0 % + 0.005 µF
1.0 % + 0.05 µF
1.0 % + 0.5 µF
1.0 % + 0.005 mF
1.0 % + 0.05 mF
4.0 % + 0.2 mF
Fluke 8846A
Thermocouple – Generate
Type E
Type J
Type K
Type N
Type R
Type S
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 750) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120 °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(120 to 400) °C
0.50 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.27 °C
0.16 °C
0.14 °C
0.17 °C
0.23 °C
0.33 °C
0.18 °C
0.16 °C
0.26 °C
0.40 °C
0.40 °C
0.22 °C
0.19 °C
0.18 °C
0.27 °C
0.57 °C
0.35 °C
0.33 °C
0.40 °C
0.47 °C
0.36 °C
0.37 °C
0.46 °C
0.14 °C
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 10 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Thermocouple – Generate
(cont)
Type T
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.63 °C
0.37 °C
0.16 °C
0.14 °C
Fluke 5522A
RTD – Generate
Pt 385 – 100 Ω
Pt 3926 – 100 Ω
Pt 3916 – 100 Ω
Pt 3985 – 200 Ω
(-200 to -80) °C
(-80 to 0 °C)
(0 to 100 °C)
(100 to 300) °C
(300 to 400) °C
(400 to 640) °C
(640 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 640) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.050 °C
0.050 °C
0.070 °C
0.090 °C
0.10 °C
0.12 °C
0.23 °C
0.050 °C
0.050 °C
0.070 °C
0.090 °C
0.10 °C
0.12 °C
0.25 °C
0.040 °C
0.050 °C
0.060 °C
0.070 °C
0.080 °C
0.090 °C
0.10 °C
0.23 °C
0.040 °C
0.040 °C
0.040 °C
0.050 °C
0.12 °C
0.13 °C
0.14 °C
0.16 °C
Fluke 5522A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 11 of 16
III. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Mass –
Fixed Points
1 mg
2 mg
3 mg
5 mg
10 mg
20 mg
30 mg
50 mg
100 mg
200 mg
300 mg
500 mg
1 g
2 g
3 g
5 g
10 g
20 g
30 g
50 g
100 g
200 g
300 g
500 g
1 kg
2 kg
3 kg
5 kg
10 kg
20 kg
25 kg
585 g
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0020 mg
0.0030 mg
0.0040 mg
0.0068 mg
0.0068 mg
0.008 mg
0.010 mg
0.017 mg
0.033 mg
0.050 mg
0.040 mg
0.080 mg
0.10 mg
0.15 mg
0.24 mg
0.5 mg
1.0 mg
1.5 mg
2.4 mg
9.6 mg
20 mg
30 mg
0.050 mg
CMC relates to
calibration of integral
conventional standard
weights | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 12 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Mass (cont)
(1 to 200) mg
(>200 to 300) mg
(>300 to 500) mg
>500 mg to 2 g
(>2 to 3) g
(>3 to 5) g
(>5 to 10) g
(>10 to 20) g
(>20 to 30) g
(>30 to 50) g
(>50 to 100) g
(>100 to 200) g
(>200 to 300) g
(>300 to 500) g
>500 g to 1 kg
(>1 to 2) kg
(>2 to 3) kg
(>3 to 5) kg
(>5 to 10) kg
(>10 to 20) kg
(>20 to 25) kg
0.0020 mg
0.0030 mg
0.0040 mg
0.0068 mg
0.0080 mg
0.010 mg
0.017 mg
0.033 mg
0.050 mg
0.040 mg
0.080 mg
0.10 mg
0.15 mg
0.24 mg
0.50 mg
1.0 mg
1.5 mg
2.4 mg
9.6 mg
20 mg
30 mg
CMC relates to
calibration of integral
conventional standard
weights
Balances (Electronic,
Non-automatic)
3
Up to 200 mg
(>200 to 500) mg
>500 mg to 2 g
(>2 to 5) g
(>5 to 10) g
(>10 to 20) g
(>20 to 50) g
(>50 to 100) g
(>100 to 200) g
(>200 to 500) g
>500 g to 1 kg
(>1 to 2) kg
(>2 to 5) kg
(>5 to 10) kg
(>10 to 30) kg
0.0025 mg
0.0045 mg
0.0070 mg
0.015 mg
0.020 mg
0.035 mg
0.075 mg
0.15 mg
0.20 mg
0.60 mg
3.0 mg
5.0 mg
10 mg
30 mg
270 mg
Class 1 weights
Centrifuges
3
(1000 to 15 000) rpm
(>15 000 to 80 000) rpm
10 rpm
43 rpm
Optical tachometer | ||
| 13 | Gravimetric Method | - | See scope document |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 14 of 16
Parameter/Equipment
Range
CMC2 (±)
Comments
Spectrophotometers –
Wavelength Peak Position
3
(279, 287, 360) nm
(445, 453, 460) nm
536 nm
0.7 nm
0.7 nm
1.0 nm
Holmium oxide filters
V. Thermodynamics
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments
Temperature – Measure
3
(-80 to 105) °C
(>105 to 150) °C
(>150 to 200) °C
(>200 to 250) °C
(>250 to 300) °C
(>300 to 350 °C
(>350 to 450) °C
(>450 to 1000) °C
0.13 °C
1 °C
2 °C
5 °C
7 °C
10 °C
12 °C
17 °C
Reference
Thermometer
Temperature –
IR Systems
(-15 to 0) °C
(>0 to 50) °C
(>50 to 100) °C
(>100 to 200) °C
(>200 to 350) °C
(>350 to 500) °C
0.31 °C
0.22 °C
0.25 °C
0.32 °C
0.56 °C
0.96 °C
Blackbody IR
calibrator
Thermocouple Thermometer
System
-196 °C
(-80 to 125) °C
(125 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1200) °C
0.35 °C
0.21 °C
0.30 °C
0.90 °C
1.4 °C
2.3 °C
Liquid bath or dry
block calibrator
Liquid-In-Glass Thermometers
(Partial & Total Immersion)
3
(-45 to 145) °C
0.020 °C
Liquid temperature
bath | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 15 of 16
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Platinum Resistance
Thermometer System
3
Fixed Point
-196 °C
(-80 to 125) °C
(>126 to 400) °C
(>401 to 600) °C
0.0073 °C
0.014 °C
0.15 °C
0.69 °C
LN2 Cell w/SPRT
Liquid bath or dry
block calibrator
Thermistor Thermometer
System
3
(-10 to 105) °C
0.067 °C
Stirred liquid bath
Relative Humidity –
Hygrometer Systems
(10 to 35) % RH
(35 to 65) % RH
(65 to 95) % RH
95 % RH
0.23 % RH
0.43 % RH
0.55 % RH
0.76 % RH
Rotronic Hygrogen
H2-S
Relative Humidity –
Measure
Up to 95 % RH
2.8 % RH
Reference hygrometer
VI. Time & Frequency
Parameter/Equipment
Range
CMC
2, 6 (±)
Comments
Frequency – Measure,
Up to 1000 V
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
(0.04 to 300) kHz
(0.3 to 1) MHz
0.1 % Hz
0.05 % Hz
0.03 % Hz
0.01 % kHz
0.01 % MHz
Fluke 8846A
Timers3
(1 to 24) hr
0.013 s/day
Timometer
Optical Tachometers
(0 to 1000) RPM
(1000 to 10 000) RPM
(10 000 to 25 000) RPM
(25 000 to 100 000) RPM
0.15 RPM
0.20 RPM
0.65 RPM
1.5 RPM
Function generator &
lamp
___________________
1 This laboratory offers commercial calibration services and field calibration services. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4946.01) Revised 06/04/2025 Page 16 of 16
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Offices for administration of field technicians are located in 145 Renfrew Dr, Markham, Ontario, Canada;
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification. | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
THERMO FISHER SCIENTIFIC operating as
UNITY LAB SERVICES
Ottawa, CANADA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 29TH day of April 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4946.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
2 other sites in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.