Humboldt Mfg Co. dba Humboldt Scientific
875 Tollgate Road, 60123, Elgin, IL, United States
- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3956.02 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 3956.02) 07/02/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
HUMBOLDT MFG CO. dba HUMBOLDT SCIENTIFIC INC.
875 Tollgate Rd
Elgin, IL 60123
Nestor Chonillo Phone: 708 468 6386
CALIBRATION
Valid To: July 31, 2027 Certificate Number: 3956.02
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Dimensional
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Linear Displacement –
Measure
(0.08 to 0.4) in
(0.4 to 1.0) in
(1.0 to 2.0) in
0.001 in
0.0007 in
0.005 in
Bore micrometer
Digital Dial Indicators
Up to 2 in
180 µin
Bore micrometer
II. Mechanical
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Load Cells
(50 to 500) lbf
(500 to 1000) lbf
(1000 to 2000) lbf
(2000 to 5000) lbf
(5000 to 10 000) lbf
0.95 %
0.47 %
0.35 %
0.28 %
0.12 %
Reference load cells | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 3956.02) 07/02/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Load Ring
(50 to 500) lbf
(500 to 1000) lbf
(1000 to 2000) lbf
(2000 to 5000) lbf
(5000 to 10 000) lbf
(10 000 to 22 000) lbf
0.39 %
0.40 %
1.5 %
0.61 %
0.30 %
0.34 %
Reference load cells
Pressure Gauge
Up to 150 psi
0.18 %
Reference pressure
transducer
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.