FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Singapore

Ametek Singapore Pte Ltd. (Compliance Test Solutions)

20 Changi Business Park Central 2, #04-03/04, Singapore, 486031, Singapore, Singapore, Singapore

A2LA|2939.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
7
Standards
14
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Ametek Singapore Pte Ltd. (Compliance Test Solutions)?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
2939.01Active

Accredited standards

14

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 3 (A2LA 2939.01)

IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5

As written on the certificate · Line 4 (A2LA 2939.01)

ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
As written on the certificate · Line 3 (A2LA 2939.01)

IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5

As written on the certificate · Line 4 (A2LA 2939.01)

ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18

IEC 61000-4-18Name not checked yet
As written on the certificate · Line 3 (A2LA 2939.01)

IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5

As written on the certificate · Line 4 (A2LA 2939.01)

ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18

ISO

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

As written on the certificate · Line 5 (A2LA 2939.01)

ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2

ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
As written on the certificate · Line 5 (A2LA 2939.01)

ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2

ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 5 (A2LA 2939.01)

ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2

ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

As written on the certificate · Line 4 (A2LA 2939.01)

ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18

ISO 7637 series

ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
As written on the certificate · Line 5 (A2LA 2939.01)

ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

As written on the certificate · Line 4 (A2LA 2939.01)

ISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18

As written on the certificate · Line 5 (A2LA 2939.01)

ISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2

ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
As written on the certificate · Line 2 (A2LA 2939.01)

ISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4

Other standards

IEC 60060-1Name not checked yet
As written on the certificate · Line 3 (A2LA 2939.01)

IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5

IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
As written on the certificate · Line 3 (A2LA 2939.01)

IEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

2939.01

The scope document we hold says it was valid until 2025-12-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 2939.01

LineDisciplineMethodMatrixRange
1Dimensional MetrologyISO/IEC 17025:2017-0.1 to 40000 V
2Electrical TestingISO 7637-2 ISO 7637-3 ESD Simulators3; ISO 10605 Voltage Dips Simulators3; ISO 16750-2; IEC 61000-4-8; IEC 61000-4-4--
3Electrical TestingIEC 61000-4-12; IEC 61000-4-18; IEC 60060-1; IEC 60950-1; IEC 61000-4-5-0.05 to 1300 µs; °; V; A; kHz
4Electrical TestingISO 7637-2; ISO 7637-2 ISO 16750-2; IEC 61000-4-5; IEC 61000-4-12; IEC 61000-4-18-9000 to 7000000000 Hz; dBm
5electricalISO 10605; ISO 11452-2; ISO 11452-4; ISO 7637-1; ISO 7637-2-9000 to 4500000000 Hz
6Dimensional Metrology--10 to 8 Hz; kHz; GHz
7Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.