IIA LAB SERVICES - IRVINE
13765 Alton Park Way, Unit E, 92618, Irvine, CA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2275.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | MetalShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2275.01) 03/26/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
IIA LAB SERVICES, LLC - IRVINE
13765 Alton Parkway, Unit E
Irvine, CA 92618
Brad Smith Phone: 949 380 7758
MECHANICAL
Valid To: March 31, 2027 Certificate Number: 2275.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s - R025 Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following dimensional testing on metals, plastics and ceramics,
aerospace, automotive parts, and medical devices and calibrations1, 6:
I. Dimensional Testing/Calibration1
Parameter Range CMC2, 4, 5 (±) Comment
Length (2D)9 –
Fixtures & Fixed Gages
Up to 2 in
Up to 50 mm
Up to 4 in
Up to 100 mm
(15 x 15) in
(380 x 380) mm
(13 + 19L) µin
(0.32 + 0.019L) µm
(16 + 14L) µin
(0.4 + 0.014L) µm
(100 + 0.55L) µin
(2.54 + 0.000 55L) µm
Contour tracing
Multi-sensor
optical system
Length (3D)9 –
Fixtures & Fixed Gages
(28 x 21 x 10) in
(700 x 530 x 250) mm
(60 x 120 x 40) in
(1500 x 300 x 1000) mm
(29 + 3.2L) µin
(1.8 + 0.0032L) µm
(76 + 3.2L) µin
(1.9 + 0.0032L) µm
Computer
controlled CMM
Computer
controlled CMM | See scope document |
| 2 | - | Parts, Fixtures & ToolingShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2275.01) 03/26/2025 Page 2 of 3
Parameter
Range
CMC2, 4, 5, 7 (±) Comment
Diameter – Measure9
Fixtures & Fixed Gages
Up to 2 in
Up to 50 mm
(22 + 4.8L) µin
(0.55 + 0.0048L) µm
Laser micrometer
Surface Roughness –
Measure9
Up to 250 µin, Ra
Up to 6.4 µm, Ra
(0.74 + 0.048A) µin
(0.02 + 0.000 05A) µm
Tactile surface
profilometry
II. Dimensional Testing8
Parameter Range CMC2, 4 (±) Comments
Length (1D)3 –
Parts, Fixtures &
Tooling
Up to 0.008 in
Up to 0.2 mm
Up to 1 in
Up to 25 mm
Up to 12 in
Up to 300 mm
Up to 24 in
Up to 600 mm
850 µin
21 µm
(90 + 16L) µin
(2.3 + 0.016L) µm
(690 + 26L) µin
(18 + 0.026L) µm
(870 + 1L) µin
(22 + 0.001L) µm
Dial indicator
Micrometer
Calipers
Height gauge
Length (2D)3 –
Parts, Fixtures &
Tooling
Detector Accuracy Z
Length Accuracy X
Up to 2 in
Up to 50 mm
Up to 4 in
Up to 100 mm
(15 x 15) in
(380 x 380) mm
(13 + 19L) µin
(0.32 + 0.019L) µm
(16 + 14L) µin
(0.4 + 0.014L) µm
(100 + 0.55L) µin
(2.54 + 0.000 55L) µm
Contour tracing
Multi-sensor optical
system | See scope document |
| 3 | - | Parts, Fixtures & Tooling; Parts & FixturesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2275.01) 03/26/2025 Page 3 of 3
Parameter
Range CMC2, 4, 5 (±) Comment
Length (3D)3 –
Parts, Fixtures &
Tooling
(28 x 21 x 10) in
(700 x 530 x 250) mm
(69 + 3.2L) µin
(2.71 + 0.0032L) µm
Computer controlled
CMM
Diameter3 –
Parts & Fixtures
Up to 2 in
Up to 50 mm
(22 + 4.8L) µin
(0.55 + 0.0048L) µm
Laser micrometer
Surface Roughness3 –
Parts & Fixtures
Up to 250 µin, Ra
Up to 6.4 µm, Ra
(0.74 + 0.048A) µin
(0.02 + 0.000 05A) µm
Tactile surface
profilometry
_______________________________________________________
1 This laboratory offers commercial dimensional testing/calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
measurements of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific measurement performed by
the laboratory may be greater than the CMC uncertainty due to the behavior of the customer’s device and
to influences from the circumstances of the specific measurement.
3 This test is not equivalent to that of a calibration.
4 In the imperial statement of CMC uncertainty, L represents the numerical value of the nominal length of
the device measured in inches and in the metric statement of CMC uncertainty, L represents the numerical
value of the nominal length of the device measured in millimeters.
5 In the statement of CMC uncertainty, A represents the numerical value of the surface roughness reading
of the device in corresponding units.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This laboratory offers commercial dimensional testing service only.
9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed and is considered equivalent to that of a calibration. | See scope document |
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- AlkemistGarden Grove, CA · ~19 kmA2LAShares 1 accredited materialMetal
- Anachem Laboratories LLCEl Segundo, CA · ~60 kmA2LAShares 1 accredited materialMetal
- Ajwa Analytical Laboratories, LLCGilroy, CA · ~502 kmA2LAShares 1 accredited materialMetal
- EUROFINS NANOLAB TECHNOLOGIESPhoenix, AZ · ~534 kmA2LAShares 1 accredited materialMetal
- AZ Laboratories LLCTempe, AZ · ~546 kmA2LAShares 1 accredited materialMetal
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.