Registers refreshed 2026-11-08.See refresh dates
United States

ORNL Surveillance and Inspection Organization

1 Bethel Valley Road, 37830, Oak Ridge, TN, United States

Visit website
A2LA 4121.01ISO/IEC 17020Register refreshed 2026-11-06
Accredited standards
19
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 19 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM18
ASTM A388
ASTM A435
ASTM A577
ASTM A578
ASTM C478
ASTM E165
ASTM E493
ASTM E499
ASTM E515
ASTM E1003
ASTM E1208
ASTM E1209
Show all 18
ASTM E1210
ASTM E1418
ASTM E1603
ASTM E2491
ASTM E2930
ASTM F1740
Other standards1
AWS D1.1

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17020

Active

4121.01

The scope document we hold says it is valid until 2027-01-31.

View scope

Accredited scope, certificate 4121.01

LineMethodMatrixRange
1DOE-STD-1090-2011; ASME B30.9; 29 CFR 1910.27; ANSI A14.3; ASTM C478/C478M--
229 CFR 1910.66; 29 CFR 1926.502; 29 CFR 1926.959; ANSI/ASE Z359.1; NFPA 1983; ASTM F1740; ASME A17.1; 17.3; ASME A18.1; ANSI A117.1; 29 CFR 1910.244; ASME PASE; ASME B30.1; ANSI MH30.1; ANSI B20.1; ASTM E515; ASME B&PV Section V, Article 10, Appendices I and II; ASTM E499/E499M; ASME B&PV Section V, Article 10, Appendix VI; ASTM E2930 and AGS G004Safety harnesses, lanyards, lifelines, anchorage connectors, shock absorbers, emergency rescue tripods; Elevators, dumbwaiters, platform (service) lifts, and stairway chairlifts; Hydraulic hand jacks, transmission jacks, engine stands, vehicle support stands, mobile lifts, service jacks, wheel dollies, shop cranes, automotive ramps, forklift jacks; Fixed and dock-face mounted leveling devices; Belt, chain, roller, roller and wheel, screw, vertical-articulated, vertical chain-operated shelf type, vertical-reciprocating equipment.; Pressure vessels and other fabricated items; Glove Boxes-
3ASTM E1603/E1603M; ASME B&PV Section V, Article 10, Appendix IX; ASTM E1003; ASTM E493/E493M; ASTM E2930; ASME B&PV Section V, Article 10, Appendix IV; ASTM /E498/E498M; ASME B&PV Section V, Article 10, Appendix V; ASME B&PV Section V-Art. 4&5; ASTM A388/388M; ASTM A435/435M; ASTM A577/577M; ASTM A578/578M; ASME B&PV Section V, XI, B31.1, ASTM E2491, E2700; ASME B&PV Section V; ASTM 165/E165M; ASTM E1209; ASTM 1417/E1417M; ASTM E1418; ASME B&PV Section V; ASTM E165/E165M; ASTM E1208; ASTM E1210; ASTM 1417/E1417M; Federal Water Pollution Control Act, Tennessee Water Quality Act, the Safe Drinking Water ActMaterials and Welds; Non-Porous Materials-
4ASME B&PV Section V; ASME B&PV Section XI; ASME B31.1; AWS D1.1; NBIC Part 2; NBIC Part 4; ASME PTC-25--
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the inspections to which this accreditation applies, please refer to the organization’s Inspection Body Scope of Accreditation. Accredited Inspection Body A2LA has accredited ORNL SURVEILLANCE AND INSPECTION ORGANIZATION Oak Ridge, TN for technical competence in and compliance with the Inspection Body Accreditation Program This inspection body is accredited in accordance with the recognized International Standard ISO/IEC 17020:2012 Conformity Assessment – Requirements for the operation of various types of bodies performing inspection. This accreditation demonstrates technical competence for a defined scope and the operation of a quality management system. Presented this 3rd day of December 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4121.01 Valid to January 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1 Bethel Valley Road, Oak Ridge, TN, 37830, US

36.01036, -84.26964

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.