Geometric Design and Technology
20040 Cochranton Rd, 16335, Meadville, PA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1984.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1984.01) 01/24/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
GEOMETRIC DESIGN AND TECHNOLOGY, INC.
20040 Cochranton Road
Meadville, PA 16335
Myrle Knickerbocker Phone: 814 336 2776
CALIBRATION
Valid To: February 28, 2027 Certificate Number: 1984.01
In recognition of the successful completion of the A2 LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requir ements) accreditation is
granted to this laboratory to perform the following calibrations and dimensional testing
1, 3:
I. Dimensional Testing/Calibration1
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
One Dimensional
5, 8 – Length
Up to 12 in
Up to 3 in
(3 to 5) in
Up to 6 in
(600 + 44L) µin
(59 + 9L) µin
(560 + 10L) µin
(94 + 10L) µin
Dimensional inspection
using:
Calipers
Micrometers
Indicators
Three Dimensional
5, 8 –
Length
Volumetric
Up to 27.5 in
Up to 18 in
(79 + 2L) µin
(310 + 7L) µin
Dimensional inspection
using:
OGP video measuring
equipment
CMM
Surface Finish
5, 8
(1 to 250) µin
2.4 µin
Fowler pocket surf
profilometer | 1 to 250 µin |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1984.01) 01/24/2025 Page 2 of 2
II. Dimensional Testing6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
One Dimensional
7, 8 –
Length
Up to 12 in
Up to 3 in
(3 to 5) in
Up to 6 in
(600 + 44L) µin
(59 + 9L) µin
(560 + 10L) µin
(94 + 10L) µin
Dimensional inspection
using:
Calipers
Micrometers
Indicators
Three Dimensional
7, 8 –
Length
Volumetric
Up to 27.5 in
Up to 18 in
(79 + 2L) µin
(310 + 7L) µin
Dimensional inspection
using:
OGP video measuring
equipment
CMM
Surface Finish
7, 8
(1 to 250) µin
2.4 µin
Fowler pocket surf
profilometer
_______________________________________
1 This laboratory offers commercial calibration/dimensional testing and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration certificate.
6 This laboratory offers commercial dimensional testing service.
7 This test is not equivalent to that of a calibration.
8 Uncertainty of measurement will be significantly higher for gages, fixtures and part pieces made from
materials other than steel. | 1 to 250 µin |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.