Cummins Technical Center - Cummins
1900 McKinley Ave, 47201, Columbus, IN, United States
- Scope lines
- 7
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 7578.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7578.01) 12/11/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
CUMMINS TECHNICAL CENTER – CUMMINS
1900 McKinley Ave
Columbus, IN 47201
Eric Miller Phone: 812-343-1176
Email: eric.s.miller@cummins.com
CALIBRATION
Valid To: November 30, 2027 Certificate Number: 7578.01
In recognition of the successful completion of the A2LA evaluation process, (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 3:
I. Chemical
Parameter/Equipment
Range
CMC2 (±)
Comments
Chemiluminescence
Analyzer
Nox:
Up to 30 µmol/mol
Up to 350 µmol/mol
Nox:
0.4 µmol/mol
3.7 µmol/mol
AVL gas divider
Heated Flame
Ionization Detector
THC:
Up to 150 µmol/mol
Up to 3000 µmol/mol
CH4:
Up to150 µmol/mol
Up to 3000 µmol/mol
THC:
1.7 µmol/mol
34 µmol/mol
CH
4:
1.9 µmol/mol
32 µmol/mol
AVL gas divider
Non-Dispersive
Infrared Analyzer
CO:
Up to 1000 µmol/mol
CO2:
Up to 40 mmol/mol
CO:
11 µmol/mol
CO
2:
0.41 mmol/mol
AVL gas divider | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7578.01) 12/11/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2 (±)
Comments
Fourier Transform
Infrared Spectroscopy
NH3:
Up to 300 µmol/mol
N2O:
Up to 300 µmol/mol
NH3:
4.8 µmol/mol
N
2O:
3.7 µmol/mol
AVL gas divider
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples –
Type E
Type J
(-200 to 900) °C
(0 to 750) °C
0.35 °C
0.35 °C
Fluke thermocouple
calibrator
III. Fluid/Flow
Parameter/Equipment
Range
CMC2 (±)
Comments
Particulate Matter Cart
Flow Rate
(8.5 to 60) slpm
1.0 slpm
Fluke Molbloc
Diluted Exhaust Flow –
Measuring Equipment
(14 to 130) mols/sec
0.60 mols/sec
Sub-sonic flow Venturi
Intake Airflow–
Measuring Equipment
Up to 4082 kg/hr
11 kg/hr
Meriam LFE
Fuel Flow–
Measuring Equipment
Up to 120 kg/hr
0.24 kg/hr
AVL fuel reference
meter | -200 to 900 °C |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7578.01) 12/11/2025 Page 3 of 3
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Pressure – Measure &
Measuring Equipment
Static P:
(-68 to 68) kPa
(0 to 1273) kPa
(0 to 3447) kPa
Static P:
0.018 kPa
0.17 kPa
0.34 kPa
Mensor pressure
calibration sensor/cart
Torque – Measure
Up to 4000 N·m
4.9 N·m
Interface load cell
Rotational Speed, RPM
– Measure
Up to 5000 RPM
0.58 RPM
Shimpo digital
tachometer
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature –
Measuring Equipment
(-10 to 122) °C
0.4 °C
Fluke dry well
calibrator
____________________________
1 This laboratory does not offer commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
CUMMINS TECHNICAL CENTER – CUMMINS
Columbus, IN
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General
requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 –
Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for
a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 11th day of December 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7578.01
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
A2LA certificate 7578.02 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNECE Reg 49; UNECE Regulation 85.00 to Supplement 10; CFR Part 1065; UNECE Regulation 49.07; UNECE Regulation 96.05; ECE Regulation 120 | compression-ignition and spark-ignited engines | - |
| 2 | UNECE Reg 49; UNECE Regulation 85.00 to Supplement 10; CFR Part 1065; UNECE Regulation 49.07; UNECE Regulation 96.05; ECE Regulation 120 | road engine emissions | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.