A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 7578.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7578.01) 12/11/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CUMMINS TECHNICAL CENTER – CUMMINS 1900 McKinley Ave Columbus, IN 47201 Eric Miller Phone: 812-343-1176 Email: eric.s.miller@cummins.com CALIBRATION Valid To: November 30, 2027 Certificate Number: 7578.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Chemical Parameter/Equipment Range CMC2 (±) Comments Chemiluminescence Analyzer Nox: Up to 30 µmol/mol Up to 350 µmol/mol Nox: 0.4 µmol/mol 3.7 µmol/mol AVL gas divider Heated Flame Ionization Detector THC: Up to 150 µmol/mol Up to 3000 µmol/mol CH4: Up to150 µmol/mol Up to 3000 µmol/mol THC: 1.7 µmol/mol 34 µmol/mol CH 4: 1.9 µmol/mol 32 µmol/mol AVL gas divider Non-Dispersive Infrared Analyzer CO: Up to 1000 µmol/mol CO2: Up to 40 mmol/mol CO: 11 µmol/mol CO 2: 0.41 mmol/mol AVL gas divider
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7578.01) 12/11/2025 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Fourier Transform Infrared Spectroscopy NH3: Up to 300 µmol/mol N2O: Up to 300 µmol/mol NH3: 4.8 µmol/mol N 2O: 3.7 µmol/mol AVL gas divider II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples – Type E Type J (-200 to 900) °C (0 to 750) °C 0.35 °C 0.35 °C Fluke thermocouple calibrator III. Fluid/Flow Parameter/Equipment Range CMC2 (±) Comments Particulate Matter Cart Flow Rate (8.5 to 60) slpm 1.0 slpm Fluke Molbloc Diluted Exhaust Flow – Measuring Equipment (14 to 130) mols/sec 0.60 mols/sec Sub-sonic flow Venturi Intake Airflow– Measuring Equipment Up to 4082 kg/hr 11 kg/hr Meriam LFE Fuel Flow– Measuring Equipment Up to 120 kg/hr 0.24 kg/hr AVL fuel reference meter
-200 to 900 °C
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7578.01) 12/11/2025 Page 3 of 3 IV. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Pressure – Measure & Measuring Equipment Static P: (-68 to 68) kPa (0 to 1273) kPa (0 to 3447) kPa Static P: 0.018 kPa 0.17 kPa 0.34 kPa Mensor pressure calibration sensor/cart Torque – Measure Up to 4000 N·m 4.9 N·m Interface load cell Rotational Speed, RPM – Measure Up to 5000 RPM 0.58 RPM Shimpo digital tachometer V. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measuring Equipment (-10 to 122) °C 0.4 °C Fluke dry well calibrator ____________________________ 1 This laboratory does not offer commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited CUMMINS TECHNICAL CENTER – CUMMINS Columbus, IN for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of December 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7578.01 Valid to November 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA certificate 7578.02 · 3 lines

LineMethodMatrixRange
1UNECE Reg 49; UNECE Regulation 85.00 to Supplement 10; CFR Part 1065; UNECE Regulation 49.07; UNECE Regulation 96.05; ECE Regulation 120compression-ignition and spark-ignited engines-
2UNECE Reg 49; UNECE Regulation 85.00 to Supplement 10; CFR Part 1065; UNECE Regulation 49.07; UNECE Regulation 96.05; ECE Regulation 120road engine emissions-
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1900 McKinley Ave, Columbus, IN, 47201, US

39.20144, -85.92138

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.