China

Xiamen Niell Electronics Co.,

No. 29 Middle Pingcheng Road, Haicang District, Xiamen, Fujian Province, 361022, People's Republic of China, Xiamen, Fujian Province, China

Visit website
A2LA 4339.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 16063-21Methods for the calibration of vibration and shock transducers - Part 21: Vibration calibration by comparison to a reference transducer

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

4339.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 4339.01

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4339.01) 09/02/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 XIAMEN NIELL ELECTRONICS CO., LTD 厦门乃尔电子有限公司 No. 29 Pingcheng Middle Road Haicang District Xiamen, Fujian Province 361022 PEOPLE’S REPUBLIC OF CHINA Fiona Yang Phone: +86 592 3774920 CALIBRATION Valid To: September 30, 2027 Certificate Number: 4339.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Dimensional Parameter/Equipment Range CMC2, 3 (±) Comments Angular Displacement Up to ± 50° 0.29 % JJF 1352 encoder Linear Displacement (1D) Up to ± 100 mm 0.19 % JJF 1305 linear moving stage II. Electrical – DC/Low Frequency Parameter/Frequency Range CMC2, 3, 5 (±) Comments DC Voltage – Measure Up to 10 V 0.06 mV DMM AC Voltage – Measure (1000 to 3000) Hz Up to 10 V 0.05 % DMM
to 50 °
2ISO 16063-21; JJG-233; GB/T 20485.21; JJF 1352; JJF 1305; JJG 860; JJG 229-1000 to 3000 Hz
3JJG 229--30 to 150 ℃
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited XIAMEN NIELL ELECTRONICS CO., LTD Xiamen, Fujian Province, PEOPLE’S REPUBLIC OF CHINA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 2nd day of September 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4339.01 Valid to September 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.