Cummins Seymour Technical Center
800 E 3rd street, 47274, Seymour, IN, United States
Visit website- Scope lines
- 6
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 7400.01 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ECE Regulation 120; CFR Part 1065; EU Regulation 2017/654 (supplementing 2016/1628) | automotive engines | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
CUMMINS SEYMOUR TECHNICAL CENTER
Seymour, IN
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 24th day of November 2025
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7400.01
Valid to September 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
A2LA certificate 7400.02 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | Gaseous Emissions Analyzers | to 2600 μmol/mol |
| 2 | - | fluidShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7400.02) 11/24/2025 Page 2 of 3
II. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Flow Meters:
Critical Flow Meter CFV1
Critical Flow Meter CFV2
Smooth Approaching Orifice
Positive Displacement Pump
Up to 4.4 SCFM
Up to 3.0 SCFM
Up to 4.4 SCFM
Up to 2.75 SCFM
0.4 %
0.73 %
1 %
1.7 %
Fluke Molbloc
Fluke Molbloc
CFV1
CFV2
III. Mechanical
Parameter/Equipment
Range
CMC2,4,6 (±)
Comments
Speed
(1 to 4000) RPM
6.8E-09x2 + 3.5E-
06x + 8.6E-01
ACT-3X infrared
tachometer
Equation translates
to 0.86 to 0.99 RPM
uncertainty
Where x = speed in
RPM
Torque –
F47 Water Dyno 12.5k lbf
F63 Water Dyno 100 KN
2025 Eddy Current Dyno 5k lbf
2025 Eddy Current Dyno 3k lbf
Up to 13 000 lbf·ft
Up to 36 000 lbf·ft
Up to 8700 lbf·ft
Up to 5200 lbf·ft
13 lbf·ft
35 lbf·ft
3.1 lbf·ft
2.1 lbf·ft
Calibration arm/
reference weight set | 1 to 4000 RPM |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7400.02) 11/24/2025 Page 3 of 3
Parameter/Equipment
Range
CMC2,4,6 (±)
Comments
Pressure –
Static Pressure
(0 to 689) kPag
(-17 to 17) kPag
(-34 to 34) kPag
17 Pag
12 Pag
18 Pag
Mensor pressure
calibration sensor/cart
IV. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature –
Type E Thermocouple
PT100 RTD (4 Wire)
(0 to 100) °C
(50 to 300) °C
(0 to 100) °C
(50 to 250) °C
0.66 °C
0.92 °C
0.37 °C
2.8E-05x + 7.4E-01
Fluke (cold block)
Fluke (hot block)
Fluke (cold block)
Fluke (hot block)
Equation translates to 0.74
to 0.75 °C uncertainty
Where x = temperature in
°C
_________________________________
1 This laboratory is not normally available for commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 In the statement of CMC, a percentage refers to a percentage of reading unless otherwise noted.
5 This accreditation covers testing/calibration performed at the main laboratory listed above.
6 If not explicitly specified, the type of instrument or material being calibrated is defined by the parameter.
This indicates the laboratory is capable of calibrating instruments that measure or generate the values in
the ranges indicated for the listed measurement parameter. | ||
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.