MANUMESURE
12-16, RUE SARAH BERNHARDT, 92600, ASNIERES SUR SEINE, France
Visit website- Accredited standards
- 32
- COFRAC certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 32 standard numbers and the 16 official names we hold. When no standard matches, it searches the method text of every scope line.
EN13
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
NF6
NF X20-301
NF X43-298
NF X43-317
NF X43-329
NF X43-551
NF X44-052
IEC 60068 series4
IEC 60068-3-5
IEC 60068-3-6
IEC 60068-3-7
IEC 60068-3-11
XP4
XP X43-132
XP X43-136
XP X43-137
XP X43-554
ISO3
ISO 10780Stationary source emissions - Measurement of velocity and volume flowrate of gas streams in ducts
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards2
FD X15-140Some clauses
Limits written next to it
FD X15-140 § 10.10
FD X15-140 § 8.9
FD X43-140
NF EN 13211; NF EN 1911; NF EN 1948-1; NF X 43-329; NF CEN/TS 17340; NF EN 14791; NF EN 14385; NF EN ISO 21877
NF X43-551; NF EN 13284-1; NF X 44-052; NF X 43-317; NF EN 1911; NF CEN/TS 17340; NF EN 14791
NF EN 12619; NF EN 14792; NF EN 15058; NF X 20-301; NF EN 14181; XP X 43-132; NF X 43-317; XP X 43-554
XP X 43-136; XP X 43-137; NF EN 14385; NF EN 13211
NF EN 15259; NF X 43-551; NF EN 14789; ISO 10780; NF EN ISO 16911-1; FD X 43-140; NF EN 14790; NF EN 13284-1; NF X 44-052
NF X 43-551; NF EN 13284-1; NF X 44-052
Arrêté du 15 décembre 2009 relatif aux contrôles techniques des valeurs limites d’exposition professionnelle sur les lieux de travail et aux conditions d’accréditation des organismes chargés des contrôles*; NF X 43-298
NF X 43-551
FD X15-140; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6
XP CEN/TS 17405; XP X 43-137; XP X 43-136
Read from the COFRAC scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.
Scope as published by COFRAC
26 lines
ISO/IEC 17025
Withdrawn1-1318
ISO/IEC 17025
Active1-7496
The scope document we hold says it is valid until 2028-02-29.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in France
- SOCOTEC ENVIRONNEMENTGUYANCOURT · ~24 kmCOFRACShares 5 accredited methods and materialsEN 13284-1EN 14385Air
- EUROFINS ANALYSES DE L'AIRSAVERNE · ~370 kmCOFRACShares 5 accredited methods and materialsEN 13284-1EN 14385Air
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~407 kmCOFRACShares 5 accredited methods and materialsEN 13284-1EN 14385Air
- LABORATOIRE DES PYRENEES ET DES LANDES - SITE DE PARDIESPARDIES · ~656 kmCOFRACShares 5 accredited methods and materialsEN 13284-1EN 14385Air
- APAVE EXPLOITATION FRANCECOFRACShares 5 accredited methods and materialsEN 13284-1EN 14385Air
Accreditation data refreshed from the COFRAC register on .