ECOCHEM

Via Ludovico Lazzaro Zamenhof 10, 36100, Vicenza, Italy

Visit website
ACCREDIA 00218ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
23
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 23 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.

EN12
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 12880Characterization of sludges - Determination of dry residue and water content
EN 13657Characterization of waste - Digestion for subsequent determination of aqua regia soluble portion of elements
EN 14039Characterization of waste - Determination of hydrocarbon content in the range of C10 to C40 by gas chromatography
EN 14346Characterization of waste - Calculation of dry matter by determination of dry residue or water content
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15936Soil, waste, treated biowaste and sludge - Determination of total organic carbon (TOC) by dry combustion
ISO8
ISO 8467Water quality - Determination of permanganate index
ISO 12039Stationary source emissions - Determination of the mass concentration of carbon monoxide, carbon dioxide and oxygen in flue gas - Performance characteristics of automated measuring systems
ISO 15587-2Water quality - Digestion for the determination of selected elements in water - Part 2: Nitric acid digestion
ISO 16703Soil quality - Determination of content of hydrocarbon in the range C10 to C40 by gas chromatography
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopesExclusion

Limits written next to it

ISO 17294-2:2023 - escluso/except

Exclusion. Written next to it on line 2 of ACCREDIA certificate 00218.

ISO 22036Environmental solid matrices - Determination of elements using inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 54321Soil, treated biowaste, sludge and waste - Digestion of aqua regia soluble fractions of elements
Other standards3
APAT CNR IRSA 4050 Man 29 2003
EPA 150.1
UNI CEN/TS 13649:2015

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

5 lines
ACCREDIA

ISO/IEC 17025

Active

00218

View scope

Accredited scope, certificate 00218

LineMethodMatrixRange
1APAT CNR IRSA 4050 Man 29 2003; APAT CNR IRSA 5160 A1 + A2 Man 29 2003; APAT CNR IRSA 5160 A2 Man 29 2003; APAT CNR IRSA 5160 A1 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 4030 A1 Man 29 2003; APAT CNR IRSA 2010 B Man 29 2003; APAT CNR IRSA 5010 A Man 29 2003; APAT CNR IRSA 5070 A2 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; ISPRA Man 117 2014; APAT CNR IRSA 2090 B Man 29 2003; UNI EN 1484:1999; APAT CNR IRSA 4020 Man 29 2003; EPA 150.1 1982; MIS1 rev. 9 2024Waste waterSee scope document
2UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 15587-2:2002; UNI EN ISO 17294-2:2023; UNI EN ISO 8467:1997; APAT CNR IRSA 3010 A + 3020 Man 29 2003; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 2090 C Man 29 2003; APAT CNR IRSA 4030 A2 Man 29 2003; UNI 10780:1998; UNI EN ISO 54321:2021; UNI EN ISO 22036:2024; UNI EN 15936:2022; DM 24/03/1986Waste water0.1 to 1 mg/l
3UNI CEI EN ISO/IEC 17025:2018; UNI CEN/TS 13649:2015; UNI EN 13657:2004; UNI EN ISO 22036:2024; APAT CNR IRSA 3020 Man 29 2003; UNI EN 14346:2007; UNI EN 12880:2002; UNI EN 12457-2:2004; UNI EN ISO 17294-2:2023; UNI EN 14039:2005; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; APAT CNR IRSA 4020 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; ISPRA Man 117 2014; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.2SoilSee scope document
4DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met XI.1 + APAT CNR IRSA 3020 Man 29 2003; UNI EN ISO 16703:2011SoilSee scope document
5UNI CEI EN ISO/IEC 17025:2018; UNI EN 12619:2013/EC1:2013; ISO 12039:2019 Annex A; ISO 12039:2001 cap 7.2; UNI EN 15058:2017; UNI EN 14792:2017; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013Stationary source emissionsSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Ludovico Lazzaro Zamenhof 10, Vicenza, 36100, IT

45.53078, 11.58875

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.