FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Italy

ITECON s.r.l.

Via Mario Tacca 5, 14049, Nizza Monferrato, Italy

ACCREDIA|00651ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
2
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ITECON s.r.l.?

Claim this profile to keep it accurate.

Register record

ACCREDIARefreshed
00651Active

Certificates and scope

1
ACCREDIA

ISO/IEC 17025

Active

00651

View scope

Accredited scope, certificate 00651

LineDisciplineMethodMatrixRange
1chemicalUNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; UNI EN ISO 15680:2005; APAT CNR IRSA 2040 B Man 29 2003; ISO 6058:1984; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; UNI EN ISO 17294-2:2023; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 5130 Man 29 2003Drinking water1 to 200 µg/l
2environmentalUNI EN 14346:2007 Met A; UNI CEI EN ISO/IEC 17025:2018Rifiuti/Wastes-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Mario Tacca 5, Nizza Monferrato, 14049, IT

44.77919, 8.36865

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.