PHINIA TECHNOLOGIES HOLDINGS MÉXICO, S DE R.L. DE C.V
Mexico Technical Center, Ave Hermanos Escobar 5756B, Ciudad Juarez, 32310, Mexico, Ciudad Juarez, Mexico
- Scope lines
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 10 scope lines.
A2LA certificate 2264.01 · 10 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 2 of 9
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Angle – Measuring
Equipment
Up to 90°
0.19°
Angle block
Pin Gage Diameter
(0.025 to 1.75) in 50 µin
Laser micrometer
Indicators – Test & Dial
Up to 1 in
(1 to 4) in
120 µin
130 µin
Gage blocks
Rulers
Up to 40 in
0.018 in
Gage blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
13 µV
69 µV
660 µV
9.0 mV
68 mV
HP 34401A
DC Voltage – Generate
Up to 329.9 mV
(0.33 to 3.29) V
(3.3 to 32.9) V
(33 to 329.9) V
(330 to 1020) V
0.0021 % + 1 μV
0.0013 % + 2 μV
0.0013 % + 20 μV
0.0018 % + 150 μV
0.0020 % + 1.5 mV
Fluke 5522A/SC600
DC Current – Measure
(Up to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(3 to 30) A
9.1 µA
130 µA
1.3 mA
5.3 mA
23 mA
HP 34401A
HP 34401A
IET DCCS-0.001 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 3 of 9
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Generate
Up to 329.9 μA
(0.33 to 3.29) mA
(3.3 to 32.9) mA
(33 to 329.9) mA
(0.33 to 1.09) A
(1.1 to 2.9) A
(3 to 10.9) A
(11 to 20.5) A
0.021 % + 0.02 μA
0.011 % + 0.05 μA
0.011 % + 0.25 μA
0.013 % + 2.5 μA
0.023 % + 40 μA
0.041 % + 40 μA
0.051 % + 500 μA
0.093 % + 750 μA
Fluke 5522A/SC600
Resistance – Measure
Up to 100 Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
17 mΩ
130 mΩ
1.3 Ω
13 Ω
130 mΩ
58 kΩ
940 kΩ
HP 34401A
Resistance – Generate
(0 to 10.9) Ω
(11 to 32.9) Ω
(33 to 109.9) Ω
(110 to 329.9) Ω
330 Ω to 1.09 kΩ
(1.1 to 3.29) kΩ
(3.3 to 10.9) kΩ
(11 to 32.9) kΩ
(33 to 109.9) kΩ
(110 to 329.9) kΩ
330 kΩ to 1.09 MΩ
(1.1 to 3.29) MΩ
(3.3 to 10.9) MΩ
(11 to 32.9) MΩ
(33 to 109.9) MΩ
(110 to 329.9) MΩ
(330 to 1100) MΩ
1.7 mΩ
2.6 mΩ
4.7 mΩ
10 mΩ
30 mΩ
100 mΩ
300 mΩ
1.0 Ω
3.0 Ω
11 Ω
35 Ω
510 Ω
1.5 kΩ
10 kΩ
62 kΩ
0.96 MΩ
16 MΩ
Fluke 5522A/SC600
AC Voltage – Measure
1 kHz
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 750) V
130 µV
1.2 mV
12 mV
120 mV
0.84 V
HP 34401A | ||
| 4 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 4 of 9
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate
(0.33 to 3.29) V
(3.3 to 32.9) V
(33 to 329.9) V
(330 to 1020) V
(1.0 to 32.9) mV
(33 to 329.9) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 450) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 90) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 8) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 450) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.028 % + 50 μV
0.017 % + 60 μV
0.019 % + 60 μV
0.028 % + 50 μV
0.064 % + 130 μV
0.23 % + 600 μV
0.015 % + 650 μV
0.015 % + 600 μV
0.025 % + 600 μV
0.033 % + 600 μV
0.085 % + 1.6 mV
0.017 % + 2 mV
0.019 % + 6 mV
0.025 % + 6 mV
0.028 % + 6 mV
0.13 % + 50 mV
0.025 % + 10 mV
0.025 % + 10 mV
0.029 % + 10 mV
0.036 % + 6 μV
0.036 % + 6 μV
0.039 % + 6 μV
0.11 % + 6 μV
0.36 % + 12 μV
0.82 % + 50 μV
0.018 % + 8 μV
0.018 % + 8 μV
0.018 % + 8 μV
0.033 % + 8 μV
0.076 % + 32 μV
0.19 % + 70 μV
Fluke 5522A/SC600 | See scope document |
| 5 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 5 of 9
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
(29 to 329.9) μA
(0.3 to 3.29) mA
(3.3 to 32.9) mA
(33 to 329.9) mA
(0.33 to 1.09) A
(1.1 to 2.9) A
(3 to 10.9) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(45 to to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
0.22 % + 0.1 μA
0.15 % + 0.1 μA
0.15 % + 0.1 μA
0.33 % + 0.15 μA
0.42 % + 0.2 μA
1.2 % + 0.4 μA
0.20 % + 0.15 μA
0.11 % + 0.15 Μa
0.11 % + 0.15 μA
0.21 % + 0.2 μA
0.49 % + 0.3 μA
0.94 % + 0.6 μA
0.18 % + 2 μA
0.055 % + 2 μA
0.052 % + 2 μA
0.082 % + 2 μA
0.20 % + 3 μA
0.36 % + 4 μA
0.18 % + 20 μA
0.049 % + 20 μA
0.049 % + 20 μA
0.11 % + 50 μA
0.22 % + 100 μA
0.42 % + 200 μA
0.056 % + 100 μA
0.056 % + 100 μA
0.69 % + 1 mA
2.8 % + 5 mA
0.066 % + 100 μA
0.066 % + 100 μA
0.66 % + 1 mA
2.6 % + 5 mA
0.11 % + 2 mA
0.11 % + 2 mA
2.9 % + 2 mA
0.18 % + 5 mA
0.18 % + 5 mA
2.8 % + 5 mA
Fluke 5522A/SC600 | See scope document |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 6 of 9
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Capacitance – Generate
(220.0 to 399.9) pF
(0.4 to 1.09) nF
(1.1 to 3.29) nF
(3.3 to 10.9) nF
(11 to 32.9) nF
(33 to 109.9) nF
(110 to 329.9) nF
(0.33 to 1.09) μF
(1.1 to 3.29) μF
(3.3 to 10.9) μF
(11 to 32.9) μF
(33 to 109.9) μF
(110 to 329.9) μF
(0.33 to 1.09) mF
(1.1 to 3.29) mF
(3.3 to 10.9) mF
(11 to 32.9) mF
(33 to 110) mF
3.5 % + 10 pF
1.6 % + 0.01 nF
0.73 % + 0.01 nF
0.62 % + 0.01 nF
0.52 % + 0.1 nF
0.35 % + 0.1 nF
0.36 % + 0.3 nF
0.62 % + 0.001 μF
0.36 % + 0.003 μF
0.37 % + 0.01 μF
0.46 % + 0.03 μF
0.73 % + 0.1 μF
0.49 % + 1 μF
0.72 % + 0.001 mF
0.49 % + 0.003 mF
0.50 % + 0.01 mF
0.85 % + 0.03 mF
1.3 % + 0.1 mF
Fluke 5522A/SC600
Oscilloscopes –
Level Sine Wave
Flatness – Bandwidth
DC Signal:
50 Ω Load
1 MΩ Load
Square Wave:
50 Ω Load
1 MΩ Load
Level Sine Wave
Amplitude
(50 kHz Reference)
Time Marker
250 kHz to 1 GHz
(-6.6 to 6.6) V
(-130 to 130) V
(-6.6 to 6.6) V
10 Hz to 10 kHz
(-130 to 130) V
10 Hz to 10 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
2 ns to 20 ms
50 ms to 5 s
1.2 Hz
0.29 % + 40 μV
0.058 % + 40 μV
1.3 % + 40 µV
1.5 % + 40 μV
0.47 % + 300 μV
2.2 % + 300 μV
2.4 % + 300 μV
5.8 µs/s
0.58 % + t · 0.1 %
Agilent E4400B
Fluke 5522A/SC600
t = time in seconds | ||
| 7 | - | RTD Indicator; Thermocouple Indicator; Scales & Balances; Accelerometers; Force – Tension & CompressionShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 7 of 9
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicator –
Measuring Instruments
Pt 385, 100 Ω
(-200 to 800) °C
(-328 to 1472) °F
0.33 °C
0.60 °F
Fluke 5522A
Electrical Simulation of
Thermocouple Indicator –
Measuring Instruments,
Type J
Type K
Type T
(-210 to 1200) °C
(-270 to 1370) °C
(-270 to 400) °C
1.3 °C
1.3 °C
0.62 °C
Fluke 525B
IV. Mechanical
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Scales & Balances
(0.25 to 300) lb
(1 to 4500) g
1 mg to 750 g
0.036 lb
530 mg
1.2 mg
NIST Class F weights
Troemner Ultra Class
(better than ASTM E617-
97 Class 1) weights
Accelerometers
(5 to < 100) Hz
(100 to 2000) Hz
(> 2000 to 10 000) Hz
4.8 %
7.1 %
5.1 %
TMS 9200D w/
PCB301A11
Endevco 28959F
w/ PCB301A11
Multimeter HP 34401A
Force – Tension &
Compression, Measuring
Equipment
(0.25 to 300) lbf
0.038 lbf
NIST Class F deadweights | - |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 8 of 9
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Pressure – Measuring
Equipment
Hydraulic
Pneumatic
Vacuum
(5 to 300) psi
(300 to 1000) psi
(1000 to 5000) psi
(0 to 300) psi
(0 to 12) psi
0.13 psi
0.041 %
0.12 %
0.029 %
0.76 %
HPC41-1kPSI
Crystal 5KPSIXP2i
DPI 611
DPI 611
Torque –
Torque Cell & Transducer
(5 to 3000) lbf∙in
0.018 %
NIST Class F
deadweight & load
arm
Torque Tools
(5 to 1200) lbf∙in
(10 to 100) lbf∙ft
(100 to 1000) lbf∙ft
0.58 %
0.58 %
0.58 %
Torque transducer
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature – Measuring
Equipment
(-80 to 200) °C
0.037 °C
Fluke 525B w/
RTD Platinum
Fluke 5615
Temperature – Measure
(-80 to 300) °C
0.037 °C
Fluke 525B w/
RTD Platinum
Fluke 5615
Temperature Sensors –
Type RTD,
T/C Types J, K, T
(-80 to 200) °C
0.071 °C
Fluke 1552A-Ex
Temperature measure –
Type RTD,
T/C Types J, K, T
(-80 to 300) °C
0.071 °C
Fluke 1552A-Ex | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2264.01) 6/29/2026 Page 9 of 9
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Relative Humidity –
Measuring Equipment
(11 to 95) % RH
2.2 % RH
Vaisala NM w/ probe
HMP75
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Frequency – Measuring
Equipment
(0.01 to 119.9) Hz
(120.0 to 1199.9) Hz
(1.20 to 11.9) kHz
(12.00 to 119.9) kHz
(120.0 to 1199.9) kHz
(1.20 to 2.00) MHz
0.0048 % + 5 μHz
0.0048 % + 5 μHz
0.0055 % + 5μHz
0.0054 % + 5μHz
0.0048 % + 5 μHz
0.029 % + 5 μHz
Fluke 5522A/SC600
Frequency – Measure
0.1 Hz to 225 MHz
180 mHz
HP 53131A
___________________________________________
1 This laboratory offers commercial calibration service
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, % is read as a percentage of reading unless otherwise noted.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 10 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Mexico Technical Center, Ave Hermanos Escobar 5756B, Ciudad Juarez, 32310, Mexico, Ciudad Juarez, MX
31.69080, -106.42532
Open in MapsAccreditation data refreshed from the A2LA register on .