HV TECHNOLOGIES
8526 Virginia Meadows Dr, 20109, Manassas, VA, United States
Visit website- Accredited standards
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60060-2
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
IEC 60060-2
IEC 61000-4-2
ISO 10605; IEC 61000-4-2; IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-12; IEC 61000-4-11
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active5102.01
The scope document we hold says it is valid until 2026-12-31.
Accredited scope, certificate 5102.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEC 61000-4-2 | - | 1900 to 31500 V |
| 2 | ISO 10605; IEC 61000-4-2; IEC 61000-4-4 | - | See scope document |
| 3 | IEC 61000-4-5 | - | See scope document |
| 4 | IEC 61000-4-12; IEC 61000-4-11 | - | 225 to 8800 V |
| 5 | IEC 60060-2 | - | See scope document |
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - MORRISVILLEMorrisville, NC · ~347 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- Technical Maintenance, Inc. - HILLIARDHilliard, OH · ~507 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- M Precision Laboratories,Shirley, MA · ~647 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- Analysis and Measurement Services Corporation (AMS)Knoxville, TN · ~649 kmA2LAShares 1 accredited test methodIEC 61000-4-2
- UL LLCNovi, MI · ~654 kmA2LAShares 1 accredited test methodISO 10605
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.