FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

ATLAS Compliance & Engineering

1792 Little Orchard Street, 95125, San Jose, CA, United States

A2LA|1007.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
12
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ATLAS Compliance & Engineering?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
1007.01Active

Accredited standards

12

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 1 (A2LA 1007.01)

ISO/IEC 17025:2017; IEC 17025; IEC 60601-1-2; IEC 61000-3-2; IEC 61000-3-3

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 1 (A2LA 1007.01)

ISO/IEC 17025:2017; IEC 17025; IEC 60601-1-2; IEC 61000-3-2; IEC 61000-3-3

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 2 (A2LA 1007.01)

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 1007.01)

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 2 (A2LA 1007.01)

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 2 (A2LA 1007.01)

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 2 (A2LA 1007.01)

IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6

IEC

IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
As written on the certificate · Line 3 (A2LA 1007.01)

IEC 62368-1; IEC 62368; IEC 60204-1; IEC 60204-33; IEC 60601-1-2

IEC 60204-33Name not checked yet
As written on the certificate · Line 3 (A2LA 1007.01)

IEC 62368-1; IEC 62368; IEC 60204-1; IEC 60204-33; IEC 60601-1-2

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
As written on the certificate · Line 1 (A2LA 1007.01)

ISO/IEC 17025:2017; IEC 17025; IEC 60601-1-2; IEC 61000-3-2; IEC 61000-3-3

As written on the certificate · Line 3 (A2LA 1007.01)

IEC 62368-1; IEC 62368; IEC 60204-1; IEC 60204-33; IEC 60601-1-2

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
As written on the certificate · Line 3 (A2LA 1007.01)

IEC 62368-1; IEC 62368; IEC 60204-1; IEC 60204-33; IEC 60601-1-2

Other standards

ANSI C63Name not checked yet
As written on the certificate · Line 4 (A2LA 1007.01)

ANSI C63

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

1007.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 1007.01

LineDisciplineMethodMatrixRange
1Electrical TestingISO/IEC 17025:2017; IEC 17025; IEC 60601-1-2; IEC 61000-3-2; IEC 61000-3-3--
2Electrical TestingIEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6--
3Electrical TestingIEC 62368-1; IEC 62368; IEC 60204-1; IEC 60204-33; IEC 60601-1-2-to 40 GHz
4electricalANSI C63Transmitters & Receiversto 40000 MHz
5Dimensional MetrologyISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1792 Little Orchard Street, San Jose, CA, 95125, US

37.30597, -121.87160

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.