DEKRA Testing and Certification Co.,
No. 26, Huaya 1st Road, Guishan District, Taoyuan City, 344, Republic of China Taiwan, Taoyuan City, Taiwan
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at DEKRA Testing and Certification Co.,?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 3100.01Active
Certificates and scope
1ISO/IEC 17025
Active3100.01
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 3100.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | 3GPP TS 51.010-4; ETSI TS 151 010-4; ETSI TS 102 230-1; 3GPP TS 31.121; 3GPP TS 34.121-1; 3GPP TS 31.124; ETSI TS 134 121; ETSI EN 301 908-2; EN 301 908-2; ETSI TS 102 230-1; 3GPP TS 31.121; 3GPP TS 31.124; 3GPP TS 34.229-1; 3GPP TS 36.521-1; ETSI EN 136 521-1; ETSI EN 301 908-13; EN 301 908-13; 3GPP TS 36.521-3; 3GPP TS 36.523-1; ETSI TS 102 230-1; 3GPP TS 38.521-1; 3GPP TS 38.521-3 (excluding FR2); 3GPP TS 38.521-4 (excluding FR2); 3GPP TS 38.523-1; 3GPP TS 38.523-2; 3GPP TS 38.523-3; 3GPP TS 38.533 (excluding FR2); 3GPP TS 34.229-5 | - | - |
| 2 | electrical | CTIA Test Plan for Wireless Device Over-the-Air Performance1,2; CTIA Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices1; CTIA Test Plan for 2x2 Downlink MIMO and Transmit Diversity Over-the-Air Performance1; CTIA 01.20 Test Methodology SISO Anechoic Chamber1; CTIA 01.40 Test Methodology MIMO1; 3GPP TS 34.114; 3GPP TS 37.544; 3GPP TS38.561; CCC-CP-012 Digital Key Applet Compliance (DK Applet Compliance); CCC-CP-020 Digital Key End-to-End Interoperability (DK E2E IOP); LoRaWAN End Device Certification Application for LW1.0.2; LoRaWAN 1.0.4 End Device Certification Requirements for All Regions; LoRaWAN 1.0.4 End Device Certification Class C Certification | - | - |
| 3 | electrical | 3GPP TS 36.523-1; EN 301 511; ETSI EN 301 511; 3GPP TS 51.010-1; ETSI TS 151 010-1; EN 301 908-1; ETSI EN 301 908-1; 3GPP TS 34.124; ETSI TS 134 124; 3GPP TS 36.124; ETSI TS 136 124; 3GPP TS 38.124; ETSI TS 138 124 | - | - |
| 4 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.