PRECILAB
3330 Earhart Drive, Suite 212A, 75006, Carrollton, TX, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2234.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | ultra-pure water; chemicals used in the semiconductor industry; H2O2; HF; DI Water; SolventsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2234.01) Revised 08/04/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PRECILAB
3330 Earhart Drive, Suite 212A
Carrollton, TX 75006
Natalie Lukomski Phone: 972-661-8360
natalie.lukomski@precilab.com
CHEMICAL
Valid To: October 31, 2026 Certificate Number: 2234.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to
perform the following tests on ultra-pure water and chemicals used in the semiconductor industry:
Test
Test Method(s)
Anions and Cations by Ion Chromatography
Anions (ppt) in Ultra-Pure Water by Ion Chromatography
Acetate, Br, Cl, F, Formate, NO2, NO3, Oxalate, PO4, SO4
PR-IN11
Anions in H2O2 by Ion Chromatography
Br, Cl, F, NO2, NO3, PO4, SO4
PR-IN16
Anions in HF by Ion Chromatography
Cl, NO3, PO4, SO4
PR-IN09
PR-IN56
Cations (ppt) in Ultra-Pure Water by Ion Chromatography
Ca, K, Li, Mg, Na, NH4+
PR-IN12
Cations in DI Water and Solvents by Ion Chromatography
Ca, K, Li, Mg, Na, NH4+ , Monomethylamine,
Dimethylamine, Trimethylamine
PR-IN21
Caustic Anion Analysis Procedure by Ion Chromatography
Br, Cl, F, NO2, NO3, PO4, SO4
PR-IN15
Anions in DI Water and Solvents by Ion Chromatography
Acetate, Br Cl, F, Formate, NO2, NO3, Oxalate, PO4, SO4
PR-IN06
Preparation of Samples for Ion Chromatography Analysis
PR-IN46
Chemical and Solvent Titrations
Acid, Base, and H2O2 Titrations by Auto-Titrator
PR-IN04
Moisture Analysis of Solvents by Karl Fischer PR-IN18 | - |
| 2 | PR-IN33; PR-IN38; PR-IN24; PR-IN61; PR-IN27; PR-IN14; PR-IN47; PR-IN02; PR-IN45; PR-IN48; PR-IN52; PR-IN58 | Water; Chemicals; Wafers; Ultra-Pure Water; Silicon Wafers; Chemicals, Solvents, and Ultra-Pure Water; Solvents; Organic Materials | - |
| 3 | PR-IN55; PR-IN57 | Solvents | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
PRECILAB
Carrollton, TX
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 12th day of August 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2234.01
Valid to October 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.