R&D Calibrations, Inc. DBA: Opto-Cal
13891 Deanly Court, 92040, Lakeside, CA, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 6198.01 · 11 lines
Below is the text of the scope document as published.
Part 1 of 11
(A2LA Cert. No. 6198.01) 10/10/2024 Page 1 of 10 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 R&D CALIBRATIONS, INC. DBA: OPTO-CAL 13891 Deanly Court Lakeside, CA 92040 Christopher Ruff Phone: 619 561 9983 CALIBRATION Valid To: August 31, 2026 Certificate Number: 6198.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Electrical – DC/Low Frequency Parameter/Equipment Range (±) CMC2, 5 Comments DC Current – Generate (0 to 2) pA (2 to 20) pA (20 to 200) pA (0.2 to 2) nA (2 to 20) nA (20 to 200) nA (0.2 to 2) µA (2 to 20) µA (20 to 200) µA (0.2 to 2) mA 0.49 % + 0.067 pA 0.44 % + 0.067 pA 0.29 % + 0.11 pA 0.085 % + 0.000 47 nA 0.075 % + 0.0035 nA 0.040 % + 0.019 nA 0.029 % + 0.000 17 µA 0.029 % + 0.0014 µA 0.029 % + 0.014 µA 0.033 % + 0.000 15 mA Keithley 263
Part 2 of 11
(A2LA Cert. No. 6198.01) 10/10/2024 Page 2 of 10 II. Optical Quantities Parameter/Equipment Range (±) CMC2, 3 Comments Spectral Irradiance (µW/cm2·nm) – Measure & Spectral Radiance – Measuring Instruments (µW/cm2·nm·sr) (350 to 360) nm (360 to 370) nm (370 to 380) nm (380 to 390) nm (390 to 400) nm (400 to 450) nm (450 to 500) nm (500 to 555) nm (555 to 600) nm (600 to 655) nm (655 to 700) nm (700 to 800) nm (800 to 900) nm (900 to 1050) nm (1050 to 1100) nm 1.5 % 1.3 % 1.2 % 1.1 % 1.1 % 1.1 % 0.83 % 0.83 % 0.7 % 0.7 % 0.6 % 0.6 % 0.6 % 0.48 % 0.48 % Osram Sylvania T6 1000W tungsten quartz- halogen lamp Chromaticity (CIE 19) – Measure x y u’ ν’ x y (350 to 750) nm (380 to 1100) nm 0.000 64 0.000 61 0.0005’ 0.000 72’ 0.002 0.0019 Osram Sylvania T6 1000W tungsten quartz- halogen lamp Note: x, y, u’ and ν’ are dimensionless quantities Gamma Scientific RS-12D Illuminance lm/m² (Lux), Illuminance lm/ft² (Foot candles) Luminance cd/m² Luminance cd/ft² (Foot lamberts) (350 to 750) nm (350 to 750) nm 1.1 % 1.1 % Osram Sylvania T6 1000W tungsten quartz- halogen lamp Luminance cd/m² (NITS) – Measure Luminance cd/ft² (Foot lamberts) -Measuring Equipment (380 to 1100) nm (380 to 1100) nm 1.1 % 1.1 % Gamma Scientific RS-12D Correlated Color Temperature (CCT) – Measuring Equipment (2600 to 3150) K 5.6 K Osram Sylvania T6 1000W tungsten quartz- halogen Lamp
Part 3 of 11
(A2LA Cert. No. 6198.01) 10/10/2024 Page 3 of 10 Parameter/Equipment Range (±) CMC2, 3 Comments Radiometric Detectors – Absolute Spectral Responsivity Amps per Watt (A/W) 200 nm 205 nm 210 nm 215 nm 220 nm 225 nm 230 nm 235 nm 240 nm 245 nm 250 nm 254.7 nm 260 nm 265 nm 270 nm 275 nm 280 nm 285 nm 290 nm 295 nm 300 nm 305 nm 310 nm 315 nm 320 nm 325 nm 330 nm 335 nm 340 nm 345 nm 350 nm 355 nm 360 nm 365 nm 370 nm 375 nm 380 nm 385 nm 390 nm 395 nm 400 nm 405 nm 410 nm 415 nm 420 nm 425 nm 430 nm 435 nm 440 nm 6.2 % 6.2 % 6.2 % 6.2 % 2.2 % 2.1 % 2.1 % 2.2 % 1.9 % 1.9 % 1.9 % 2.0 % 1.6 % 1.6 % 1.6 % 1.7 % 1.1 % 1.1 % 1.2 % 1.1 % 1.1 % 1.1 % 1.2 % 1.1 % 1.0 % 1.1 % 1.0 % 1.1 % 1.1 % 1.1 % 1.2 % 1.3 % 1.2 % 1.2 % 1.2 % 0.9 % 0.8 % 0.8 % 0.8 % 0.8 % 0.7 % 0.7 % 0.7 % 0.7 % 0.7 % 0.7 % 0.7 % 0.7 % 0.7 % Hamamatsu S2281 & Gamma Scientific NM- 7H
Extracted from the scope document; tables may not line up. View scope for the original.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.