Delta Inspection
36251 Schoolcraft Road, 48150, Livonia, MI, United States
- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3264.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3264.01) 05/29/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
DELTA INSPECTION
36251 Schoolcraft Road
Livonia, MI 48150
John O. Schultz Phone: 734 793 2394
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 3264.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Dimensional
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Major Diameter – Measure
(0.030 to 8.00) in
(56 + 25L) µin
SIP 300M,
master gage blocks
Minor Diameter – Measure
(0.030 to 8.00) in
(56 + 25L) µin
SIP 300M,
master gage blocks
(DOP) Dimension Over Pins –
External Gear or Spline
(0.030 to 8.00) in
(79 + 25L) µin
SIP 300M, gage pins,
master gage blocks
(DBP) Dimension Between
Pins – Internal Gear or Spline
(0.100 to 8.00) in
(86 + 25L) µin
Master gage blocks,
gage pins
_____________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | 0.03 to 8 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3264.01) 05/29/2025 Page 2 of 2
3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.