What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 26 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO15
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 16703Soil quality - Determination of content of hydrocarbon in the range C10 to C40 by gas chromatography
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 19458Water quality - Sampling for microbiological analysis
ISO 20595Water quality - Determination of selected highly volatile organic compounds in water - Method using gas chromatography and mass spectrometry by static headspace technique (HS-GC-MS)
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
ISO 28540Water quality - Determination of 16 polycyclic aromatic hydrocarbons (PAH) in water - Method using gas chromatography with mass spectrometric detection (GC-MS)
ISO 54321Soil, treated biowaste, sludge and waste - Digestion of aqua regia soluble fractions of elements
EN10
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13657Characterization of waste - Digestion for subsequent determination of aqua regia soluble portion of elements
EN 14039Characterization of waste - Determination of hydrocarbon content in the range of C10 to C40 by gas chromatography
EN 14346Characterization of waste - Calculation of dry matter by determination of dry residue or water content
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15216Environmental solid matrices - Determination of total dissolved solids (TDS) in water and eluates
Other standards1
APAT CNR IRSA 1030 Man 29 2003
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; APAT CNR IRSA 2050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2090 A Man 29 2003; UNI 11758:2019; UNI EN ISO 6222:2001; APAT CNR IRSA 3020 Man 29 2003; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; MU 2251:08; APAT CNR IRSA 2020 A Man 29 2003
UNI EN ISO 9377-2:2002; NIOSH 2016 2016; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; UNI 10780:1998 App C; DM 06/09/1994 GU n 288 10/12/1994 All 3; UNI EN 14039:2005; UNI EN 13657:2004; UNI EN ISO 11885:2009; UNI EN 14346:2007 Met A; UNI EN 12457-2:2004; UNI EN ISO 11885:2009; UNI EN ISO 10304-1:2009; UNI EN 12457-2:2004; UNI EN ISO 10523:2012; UNI EN 12457-2:2004; UNI EN 15216:2021; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021 Met B + UNI EN ISO 11885:2009; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1
UNI CEI EN ISO/IEC 17025:2018; ISO 20595:2018; UNI EN ISO 10304-1:2009; UNI ISO 23695:2023; ISO 28540:2011; APAT CNR IRSA 3010 B + 3020 Man 29 2003; Legge n 319 10/05/1976 GU n 141 29/05/1976 Tab A p.to 5 + APAT CNR IRSA 2090 B Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 5210 D (2019); APAT CNR IRSA 2090 B Man 29 2003
APAT CNR IRSA 1030 Man 29 2003; UNI EN ISO 19458:2006; UNI EN 12619:2013/EC1:2013; UNI EN 14792:2017; UNI EN 15058:2017; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
4 lines
ISO/IEC 17025
Active01450
Accredited scope, certificate 01450
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 11731:2017; APAT CNR IRSA 2050 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2090 A Man 29 2003; UNI 11758:2019; UNI EN ISO 6222:2001; APAT CNR IRSA 3020 Man 29 2003; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; MU 2251:08; APAT CNR IRSA 2020 A Man 29 2003 | Drinking water | - |
| 2 | UNI CEI EN ISO/IEC 17025:2018; ISO 20595:2018; UNI EN ISO 10304-1:2009; UNI ISO 23695:2023; ISO 28540:2011; APAT CNR IRSA 3010 B + 3020 Man 29 2003; Legge n 319 10/05/1976 GU n 141 29/05/1976 Tab A p.to 5 + APAT CNR IRSA 2090 B Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 5210 D (2019); APAT CNR IRSA 2090 B Man 29 2003 | Drinking water | - |
| 3 | UNI EN ISO 9377-2:2002; NIOSH 2016 2016; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; UNI 10780:1998 App C; DM 06/09/1994 GU n 288 10/12/1994 All 3; UNI EN 14039:2005; UNI EN 13657:2004; UNI EN ISO 11885:2009; UNI EN 14346:2007 Met A; UNI EN 12457-2:2004; UNI EN ISO 11885:2009; UNI EN ISO 10304-1:2009; UNI EN 12457-2:2004; UNI EN ISO 10523:2012; UNI EN 12457-2:2004; UNI EN 15216:2021; UNI EN ISO 16703:2011; UNI EN ISO 54321:2021 Met B + UNI EN ISO 11885:2009; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met II.1 | Soil | 5 to 10000 mg/kg |
| 4 | APAT CNR IRSA 1030 Man 29 2003; UNI EN ISO 19458:2006; UNI EN 12619:2013/EC1:2013; UNI EN 14792:2017; UNI EN 15058:2017; UNI EN 14789:2017; UNI EN 14790:2017; UNI EN ISO 16911-1:2013 | Waste water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- Lifeanalytics TorinoRobassomero · ~19 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 11731:2017Drinking water
- ARCADIA S.R.L. a socio unicoTromello · ~92 kmACCREDIAShares 5 accredited methods and materialsEN ISO 11731:2017EN ISO 9377-2:2002Drinking water
- INDAM LABORATORI SrL a socio unicoCastel Mella · ~191 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 9377-2:2002Drinking water
- BIOCHEMIE LAB S.r.l.Campi Bisenzio · ~320 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 9377-2:2002Drinking water
- LECHER RICERCHE E ANALISISalzano · ~342 kmACCREDIAShares 5 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EN ISO 11731:2017Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.