Poland

Powiatowa Stacja Sanitarno-Epidemiologiczna w Inowrocławiu

Plac Klasztorny 1b, 88-100, Inowrocław, Poland

PCA AB 764ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
15
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO11
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-3Water quality - Detection and enumeration of Escherichia coli and coliform bacteria - Part 3: Miniaturized method (Most Probable Number) for the detection and enumeration of E. coli in surface and waste water
ISO 10523Water quality - Determination of pH
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
Other standards4
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
PN-82/C-04576/08
PN-C-04576-04

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

3 lines
PCA

ISO/IEC 17025

Active

AB 764

The scope document we hold says it was valid until 2026-09-17. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.

View on PCA

Accredited scope, certificate AB 764

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 764 Scope of accreditation No AB 764 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ I CERTYFIKACJI ŻYWNOŚCI HANNA TUGI Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 764 z dnia 22.07.2020 r. Cykl akredytacji od 01.08.2022 r. do 17.09.2026 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 764 of 22.07.2020 Accreditation cycle from 01.08.2022 to 17.09.2026 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 17, 26.06.2025 1/4 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 764 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 17 z/of 26.06.2025 Nazwa i adres / Name and address POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA W INOWROCŁAWIU Plac Klasztorny 1b 88-100 Inowrocław Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/28; C/29 - Badania chemiczne wody, wody do spożycia przez ludzi/ Chemical tests of water, drinking water - N/28; N/29 - Badania właściwości fizycznych wody, wody do spożycia przez ludzi / Tests of physical properties of water, drinking water - K/28; K/29 - Badania mikrobiologiczne wody, wody do spożycia przez ludzi / Microbiological tests of water, drinking water Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 764
-
2PN-92/C-04590/02; PN-82/C-04576/08; PN-EN 26777:1999; PN-ISO 6332:2001; PN-ISO 6332:2001/Ap1:2016-06; PN-C-04576-04:1994; PN-EN ISO 10523:2012; PN-EN ISO 7887:2012 +Ap1:2015-06; PN-EN 27888:1999; PN-ISO 9297:1994; PN-EN ISO 8467:2001; PN-EN ISO 7027-1:2016Drinking waterSee scope document
3PN -EN ISO 9308-1:2014-12; PN -EN ISO 9308-1:2014-12/A1:2017-04; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PB-04/LHK; PN-EN ISO 16266:2009; PN-EN ISO 9308-3:2002Drinking water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Plac Klasztorny 1b, Inowrocław, 88-100, PL

52.79732, 18.25850

Open in Maps