Poland
M-LAB Mirosław Pracki
ul. Gazowa 2/2, 88-192, Piechcin, Poland
PCA|AB 1498ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
5
Locations
1
Contact this laboratory
Register record
- PCACollected
- AB 1498Active
Certificates and scope
1PCA
ISO/IEC 17025
ActiveAB 1498
Accredited scope, certificate AB 1498
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | - | working environment (harmful factors - air); working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate); general environment (physical factors – noise); working environment (harmful factors - air) | - |
| environmental | PN-EN 14253+A1:2011; PN-EN ISO 5349-1:2004; PN-EN ISO 5349-2:2004; PN-EN ISO 5349-1:2004+A1:2015-11 | Workplace environment | 0.03 to 25 ms-2 |
| environmental | PN-EN ISO 11079:2008; PN-EN ISO 7243:2018-01; PN-EN-ISO 7730:2006+Ap2:2016-04 | Workplace environment | -30 to 60 °C; %; m/s |
| environmental | PN-Z-04507:2022-05; PN-Z-04507:2022-05/Ap1:2022-08; PN-Z-04508:2022-05; PN-Z-04508:2022-05/Ap1:2022-08; Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) | Ambient air | 0.2 to 137 mg/m3; dB |
| environmental | PN-N-01307:1994; PN-EN ISO 9612:2011; PN-83/E-04040.03; PN-Z-04008-7:2002+Az1:2004; PB-01 wydanie 3 z dnia 03.11.2025 r. | Air | 28 to 137 dB |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium SMC Spółka z ograniczoną odpowiedzialnościąMichałowice · ~186 kmPCAShares 6 accredited methods and materialsEN 14253+A1:2011PN-N-01307:1994PN-Z-04507:2022-05
- Ośrodek Badań Podstawowych Projektów i Wdrożeń Ochrony Środowiska i Biotechnologii "OIKOS"Święta Katarzyna · ~289 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04507:2022-05
- GRUPA EKOPROJEKTBielsko-Biała · ~341 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04507:2022-05
- ANPO Lab Piotr DobrzyńskiBiałystok · ~344 kmPCAShares 6 accredited methods and materialsEN ISO 11079:2008PN-N-01307:1994PN-Z-04507:2022-05
- PRO-LAB Usługi Chemiczno-Środowiskowe P.Drop, K.Drop S.C.Inowrocław · ~15 kmPCAShares 5 accredited methods and materialsEN 14253+A1:2011EN ISO 11079:2008PN-N-01307:1994
Accreditation data collected from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.