United Kingdom
Build Check
Hayloaders Works, Wotton Road, Brill, HP18 9UB, Aylesbury, United Kingdom
UKAS|4044ISO/IEC 17025Register collected 2026-09-11
Certificates
1
Scope items
8
Locations
1
Contact this laboratory
Work at Build Check?
Claim this profile to keep it accurate.
Register record
- UKASCollected
- 4044Withdrawn
Certificates and scope
1UKAS
ISO/IEC 17025
Withdrawn4044
Accredited scope, certificate 4044
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| Electrical Testing | BS EN ISO 10077-1:2017 BS EN ISO 10077-2:2017 BS EN 673:2011 Lab WINDOWS and DOORS Air permeability BS EN 1026:2016 A Watertightness BS EN 1027:2000 BS EN 1027: 2016 A Resistance to wind load BS EN 12211:2016 A Weathertightness BS 6375-1:2015 A WINDOWS Operating forces BS 6375-2:2009 BS EN 12046-1:2020 A Static torsion BS 6375-2:2009 BS EN 14609:2004 A Racking BS 6375-2:2009 BS EN 14608:2004 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 14609:2004 As modified by in-house procedure OP208 A DOORS Operating forces BS 6375-2:2009 BS EN 12046-2:2000 BS EN 12217:2003 A Vertical load BS 6375-2:2009 BS EN 947:1999 BS EN 1192:2000; BS 6375-1; BS 6375-2; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 10077-1:2017 BS EN ISO 10077-2:2017 BS EN 673:2011 Lab WINDOWS and DOORS Air permeability BS EN 1026:2016 A Watertightness BS EN 1027:2000 BS EN 1027: 2016 A Resistance to wind load BS EN 12211:2016 A Weathertightness BS 6375-1:2015 A WINDOWS Operating forces BS 6375-2:2009 BS EN 12046-1:2020 A Static torsion BS 6375-2:2009 BS EN 14609:2004 A Racking BS 6375-2:2009 BS EN 14608:2004 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 14609:2004 As modified by in-house procedure OP208 A DOORS Operating forces BS 6375-2:2009 BS EN 12046-2:2000 BS EN 12217:2003 A Vertical load BS 6375-2:2009 BS EN 947:1999 BS EN 1192:2000 | Air | - |
| Electrical Testing | BS EN 14019:2016; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025 | Drinking water | - |
| Materials Testing | BS EN 13051:2001 Site Hose Test AAMA 501; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025 | Water | - |
| Materials Testing | PAS 24:2022; PAS 24:2016; ISO/IEC 17025:2017 | DOORSETS; WINDOWS | - |
| Mechanical Testing | BS EN 948:1999 BS EN 1192:2000 A Soft and heavy body impact BS 6375-2:2009 BS EN 13049:2003 BS EN 949:1999 BS EN 1192:2000 A Hard body impact BS 6375-2:2009 BS EN 950:1999 BS EN 1192:2000 A Load bearing capacity of safety devices BS 6375-2:2009 BS EN 948:1999 as modified by Documented In-House Method No OP208 A DOOR AND SHUTTER ASSEMBLIES Smoke control BS EN 1634-3:2004; BS 6375-2; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; In-House Method No | DOORS; DOOR AND SHUTTER ASSEMBLIES; DOORSETS | - |
| mechanical | EN 14351-1:2006+A2:2016 | Doors, windows, shutters, blinds, gates and related building hardware | - |
| mechanical | EN 14351-1:2006+A2:2016 | Doors, windows, shutters, blinds, gates and related building hardware | - |
| - | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in United Kingdom
- BASEC GroupMilton Keynes · ~25 kmUKASShares 3 accredited materialsAirDrinking waterWater
- BSI Assurance UKMilton Keynes · ~25 kmUKASShares 3 accredited materialsAirDrinking waterWater
- BRE GLOBAL LIMITED Incorporating LPC Testing, BRE TestingWatford · ~34 kmUKASShares 3 accredited materialsAirDrinking waterWater
- SATRA Technology CentreNorthamptonshire · ~55 kmUKASShares 3 accredited materialsAirDrinking waterWater
- EUROFINS ELECTRICAL AND ELECTRONIC UK LIMITED (Trading as Eurofins E&E UK – London Laboratory)London · ~58 kmUKASShares 3 accredited materialsAirDrinking waterWater
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.