Schalltechnisches Ingenieurbüro Pies
Birkenstraße 34, 56154, Boppard-Buchholz, Germany
- Accredited standards
- 20
- DAKKS certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 20 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO14
ISO 1Geometrical product specifications (GPS) - Standard reference temperature for the specification of geometrical and dimensional properties
ISO 3382-2Acoustics - Measurement of room acoustic parameters - Part 2: Reverberation time in ordinary rooms
ISO 3382-3Acoustics - Measurement of room acoustic parameters - Part 3: Open plan offices
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 3746Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
ISO 8297Acoustics - Determination of sound power levels of multisource industrial plants for evaluation of sound pressure levels in the environment - Engineering method
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
ISO 10052Acoustics - Field measurements of airborne and impact sound insulation and of service equipment sound - Survey method
ISO 11201Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and at other specified positions in an essentially free field over a reflecting plane with negligible environmental corrections
ISO 11202Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and at other specified positions applying approximate environmental corrections
ISO 16032Acoustics - Measurement of sound pressure level from service equipment or activities in buildings - Engineering method
ISO 16283-1Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation
ISO 16283-2Acoustics - Field measurement of sound insulation in buildings and of building elements - Part 2: Impact sound insulation
DIN5
DIN 45642
DIN 45645-1
DIN 45645-2
DIN 45680
DIN 45681
Other standards1
45688:2014
DIN EN ISO 16283 -1; DIN EN ISO 16283 -2; DIN EN ISO 1 6283 -3; DIN EN ISO 16032; DIN EN ISO 10052; DIN EN ISO 3382 -2; DIN EN ISO 3382 -3
DIN EN ISO 3744; DIN EN ISO 3746
18. BImSchV; AVwV Baulärm; LAI -Freizeitlärm -RL; DIN ISO 8297; DIN ISO 9613 -2; DIN 45642; DIN 45645 -1; DIN 45680; DIN 45680 Bbl. 1; DIN 45681; DIN 45681 Ber. 2; VDI 3745 Bl. 1
DIN EN ISO 9612; DIN EN ISO 11201; DIN EN ISO 11202; DIN 45645 -2
DIN 45688:2014; TA Lärm 1998-08; TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 16. BImSchV 2014-12; 16. BImSchV 2020-11
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-23049-01-00
Accredited scope, certificate D-PL-23049-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-23049-01-01
Accredited scope, certificate D-PL-23049-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Geräuschemissionen von Maschinen; Geräuschen in der Nachbarschaft; Modul Immissionsschutz; Geräusche am Arbeitsplatz | - |
| 2 | DIN EN ISO 3744; DIN EN ISO 3746 | - | - |
| 3 | DIN 45688:2014; TA Lärm 1998-08; TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; 16. BImSchV 1990-06; 16. BImSchV 2014-12; 16. BImSchV 2020-11 | Geräusche in der Nachbarschaft | - |
| 4 | 18. BImSchV; AVwV Baulärm; LAI -Freizeitlärm -RL; DIN ISO 8297; DIN ISO 9613 -2; DIN 45642; DIN 45645 -1; DIN 45680; DIN 45680 Bbl. 1; DIN 45681; DIN 45681 Ber. 2; VDI 3745 Bl. 1 | - | - |
| 5 | DIN EN ISO 9612; DIN EN ISO 11201; DIN EN ISO 11202; DIN 45645 -2 | Geräusche am Arbeitsplatz | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-23049-01-02
Accredited scope, certificate D-PL-23049-01-02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
| 2 | DIN EN ISO 16283 -1; DIN EN ISO 16283 -2; DIN EN ISO 1 6283 -3; DIN EN ISO 16032; DIN EN ISO 10052; DIN EN ISO 3382 -2; DIN EN ISO 3382 -3 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- IFL Institut für LärmschutzDüsseldorf · ~133 kmDAKKSShares 2 accredited test methods45688:2014EN ISO 9001
- FCP IBU GmbH FCP IBU EssenEssen · ~141 kmDAKKSShares 2 accredited test methods45688:2014EN ISO 9001
- ITA Ingenieurgesellschaft für Technische Akustik Weimar mbHWeimar · ~277 kmDAKKSShares 2 accredited test methods45688:2014EN ISO 9001
- ALB Akustiklabor Berlin Albrecht, Deter, Passow Partnerschaft von Ingenieuren mbBBerlin · ~471 kmDAKKSShares 2 accredited test methods45688:2014EN ISO 9001
- WIND - consult Ingenieurgesellschaft für umweltschonende Energiewandlung mbHAdmannshagen-Bargeshagen · ~529 kmDAKKSShares 2 accredited test methods45688:2014EN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.