Registers refreshed 2026-11-08.See refresh dates
Italy

Officine Santafede

via Fregera 1 - fraz. Cortabbio, 23819, Primaluna, Italy

Visit website
ACCREDIA 01372ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
10
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM A262Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM A923Standard Test Methods for Detecting Detrimental Intermetallic Phase in Duplex Austenitic/Ferritic Stainless Steels
ASTM E10Standard Test Method for Brinell Hardness of Metallic MaterialsExclusion

Limits written next to it

ASTM E10-23 - escluso/except par.

Exclusion. Written next to it on line 1 of ACCREDIA certificate 01372.

ASTM E18Standard Test Methods for Rockwell Hardness of Metallic MaterialsExclusion

Limits written next to it

ASTM E18-25 - escluso/except par.

Exclusion. Written next to it on line 1 of ACCREDIA certificate 01372.

ASTM E112Standard Test Methods for Determining Average Grain SizeSome methods

Limits written next to it

ASTM E112-25 - solo/only metodo per

Some methods. Written next to it on line 1 of ACCREDIA certificate 01372.

ASTM E1245
ASTM G28
ASTM G48Standard Test Methods for Pitting and Crevice Corrosion Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution
ISO 3651-2Determination of resistance to intergranular corrosion of stainless steels - Part 2: Ferritic,austenitic and ferritic-austenitic (duplex) stainless steels - Corrosion test in media containing sulfuric acid

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.

Scope as published by ACCREDIA

2 lines
ACCREDIA

ISO/IEC 17025

Active

01372

View scope

Accredited scope, certificate 01372

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 3651-2:2000/EC1:2002; ASTM A262-15(2021) Met E; ASTM A923-25 Met A; ASTM A923-25 Met B; ASTM A923-25 Met C; ASTM G48-25 Met A; ASTM G28-24 Met A; ASTM E112-25; ASTM E1245-03(2023); ASTM E10-23; ASTM A370-24a; ASTM E18-25Metal0 to 100 %
2

Extracted from the scope document; tables may not line up. View scope for the original.

Officine Santafede srl via Fregera 1 - fraz. Cortabbio 23819 Primaluna LC Legenda/Note Allegato al certificato di accreditamento n. 01372 rev. 3 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 29 Sede A Data: 17/11/2025 pag. 2 di 2 Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not provided for by the method but acceptable Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title, see ACCREDIA General Regulation RG-02. Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the accreditation certificate issued to the laboratory. L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions and interpretations based on the results of the specific marked tests. L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that a suspension of accreditation is active for the specific activity shown next to it.

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

via Fregera 1 - fraz. Cortabbio, Primaluna, 23819, IT

45.98697, 9.42961

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.