J-TEC Associates
5005 Blairs Forest Lane NE, Suite L, 52402, Cedar Rapids, IA, United States
Visit website- Scope lines
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 2 scope lines.
A2LA certificate 3773.01 · 2 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3773.01) 11/25/2025 Page 1 of 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
J-TEC ASSOCIATES, INC.
5005 Blairs Forest Lane NE, Suite L
Cedar Rapids, IA 52402
Brent Bormann Phone: 319 393 5200 ext. 320
CALIBRATION
Valid To: October 31, 2027 Certificate Number: 3773.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Volumetric Flow3 –
Measuring Equipment
DC Voltage (Flow)
Frequency (Flow)
(0.14 to 600) ACFM
Up to 5 V
Up to 5 kHz
1.3 % of Full Scale
1.3 % of Full Scale
1.3 % of Full Scale
Custom flow stand,
laminar flow elements
(LFEs)
LabJack T4
ProSense SCU-2501
_________________________
1 Commercial calibration service is available for this laboratory.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The contributions from the “best existing device” are not included in the CMC claim.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | 0.14 to 600 ACFM |
| 2 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.