Canada

Creaform

Levis, Canada

Visit website
A2LA 4274.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
2
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 10360-8Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 8: CMMs with optical distance sensors
ISO 10360-12Geometrical product specifications (GPS) - Acceptance and reverification tests for coordinate measuring systems (CMS) - Part 12: Articulated arm coordinate measurement machines (CMM)

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

4274.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 4274.01

LineMethodMatrixRange
1ASME B89.4.22-2004; ISO 10360-12; VDI/VDE 2634 Part 3Optical Portable CMM; Optical Portable 3D Scannerto 2 m
2VDI/VDE 2634 Part 3; ISO10360-8-to 1.5 m
3-Precision Bar and Sphere Size
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4274.01) Revised 06/29/2026 Page 3 of 3 Parameter/Equipment Range CMC2 (±) Comments Precision Bar and Sphere Size – Probing Size Error Length Measurement Error Up to 50.8 mm Up to 900 mm 1.9 μm 3.1 μm ATP001-01 as per Creaform calibration procedure using: coordinate measuring machine _____________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
to 900 mm
4ISO/IEC 17025:2017; R205 – Specific Requirements: Calibration Laboratory Accreditation Program--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.