What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1276.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1276.01) 05/09/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
WEISS TECHNIK NORTH AMERICA, INC.
3881 North Greenbrooke SE
Grand Rapids, MI 49512
Cindy Kelley Phone: 616 554 5020
CALIBRATION
Valid To: February 28, 2027 Certificate Number: 1276.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Electrical – DC/Low Frequency
Parameter/Equipment
Range CMC2, 6 (±) Comments
DC Voltage – Generate3
(0 to 10) mV
(>0.1 to 1) V
(>1 to 15) V
0.01 % + 5 µV
0.012 % + 50 µV
0.01 % + 500 µV
Fluke 753/754
DC Current – Generate3
(0.1 to 22) mA
0.011 % + 3 µA
Fluke 753/754
Electrical Calibration of
RTD & Thermocouple Indicating
Systems
3 –
PT100, 385 Ω
PT100, 3916 Ω
PT100, 3962 Ω
Type T
(-200 to <100) °C
(100 to 260) °C
(-200 to <100) °C
(100 to 260) °C
(-200 to <100) °C
(100 to 260) °C
(-80 to 0) °C
(0 to 200) °C
0.036 °C
0.05 °C
0.037 °C
0.05 °C
0.037 °C
0.05 °C
0.83 °C
0.79 °C
Fluke 753/754, 4-wire | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1276.01) 05/09/2025 Page 2 of 2
II. Thermodynamics
Parameter/Equipment
Range CMC2, 5 (±) Comments
Relative Humidity –
Measure3
(10 to 90) % RH
(>90 to 95) % RH
1.3 % RH
1.8 % RH
Vaisala HMP77B
Temperature – Measure3
(-80 to 0) °C
(0 to 200) °C
(-80 to 0) °C
(0 to 200) °C
(-80 to 0) °C
(0 to 200) °C
1.4 °C
1.4 °C
1.8 °C
1.8 °C
1.3 °C
1.2 °C
Fluke 753/745 with type T
thermocouple
Fluke 753/754 with type K
thermocouple
Keithley DAQ6510 w/ 7700
& type-T thermocouple
________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually
using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration
performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device
and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges
indicated for the listed measurement parameter.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured
value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range
or as a percent or fraction of the reading plus a fixed floor specification. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.