FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

Parker Hannifin Chomerics Test Services - Woburn, MA

84 Dragon Court, 01801, Woburn, MA, United States

A2LA|1980.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
10
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Parker Hannifin Chomerics Test Services - Woburn, MA?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
1980.01Active

Accredited standards

10

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

As written on the certificate · Line 3 (A2LA 1980.01)

MIL-STD-461C/462; MIL-STD-461D/E/F/G; RTCA DO-160 D/E/F/G; ANSI C63.4:2014; FCC MP-5 (February 1986)

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says EN 55014-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurementCertificate says EN 55022. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

FCC PART 15Radio Frequency Devices
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 1 (A2LA 1980.01)

FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

1980.01

The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 1980.01

LineDisciplineMethodMatrixRange
1electricalFCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3-to 18 GHz
2-
(A2LA Cert. No. 1980.01) 06/27/2024 Page 2 of 3 Test Technology: Test Method(s) 1, 2: Immunity (continued) Electrical Fast Transient/Burst EN 61000-4-4 (2004+A1:2010, 2012); IEC 61000-4-4 (2004+A1:2010, 2012); KN 61000-4-4; KS C 9610-4-4; AS/NZS 61000.4.4 Surge Immunity EN 61000-4-5 (2006, 2014), (2016 + A1:2018); IEC 61000-4-5 (2005, 2014); KN 61000-4-5; KS C 9610-4-5; AS/NZS 61000.4.5 Conducted Immunity EN 61000-4-6 (2009, 2014); IEC 61000-4-6 (2008, 2013); KN 61000-4-6; KS C 9610-4-6; AS/NZS 61000.4.6 Power Frequency Magnetic Field Immunity EN 61000-4-8 (2010); IEC 61000-4-8 (2009); KN 61000-4-8; KS C 9610-4-8; AS/NZS 61000.4.8 Voltage Dips, Short Interruptions, and Line Voltage Variations EN 61000-4-11 (2004, A1:2018, 2020); IEC 61000-4-11 (2004); KN 61000-4-11; KS C 9610-4-11; AS/NZS 61000.4.11 Close Proximity Radiated Field Immunity EN/IEC 61000-4-39 (2017) Generic Standards EN/IEC 61000-6-1; KS C 9610-6-1; EN/IEC 61000-6-2; KS C 9610-6-2; EN/IEC 61000-6-3; KS C 9610-6-3; EN/IEC 61000-6-4; KS C 9610-6-4; AS/NZS 61000.6.1; AS/NZS 61000.6.2; AS/NZS 61000.6.3; AS/NZS 61000.6.4 Product Standards IEC/CISPR 14-2; EN/IEC 55014-2; IEC/CISPR 24; EN/IEC 55024; ETSI EN 302 340 (Section 6.2); ETSI EN 301 843-1; ETSI EN 301 843-6; ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-17; EN 55103-1; EN 55103-2; KS C 9814-2; KN 24; CISPR 25; KS C 9835; EN55035; CISPR 35; EN/IEC 60945 (Sections 9, 10, and 11.2); EN/IEC 61326-1; EN/IEC 61326-2-1; EN/IEC 61326-2-2; EN/IEC 61326-2-3; EN/IEC 61326-2-4; EN/IEC 61326-2-5; EN/IEC 61326-2-6; AAMI/EN/IEC 60601-1-2; KS C IEC 60601-1-2; AAMI/EN/IEC 60601-2-2; EN/IEC 60601-2-4; EN/IEC 60601-2-18; EN/IEC 60601-2-23; EN/IEC 60601-2-24; AAMI/EN/IEC 60601-2-25; EN/IEC 60601-2-26; AAMI/EN/IEC 60601-2-27; EN/IEC 60601-2-34; EN/IEC 60601-2-37; AAMI/EN/IEC 60601-2-47; EN/IEC 60601-2-49; EN 60601-1-10; EN 60730-1; EN 60730-2-9; EN 60601-1-12 (Section 11 only); EN 63044-5-1; EN 63044-5-2
3electricalMIL-STD-461C/462; MIL-STD-461D/E/F/G; RTCA DO-160 D/E/F/G; ANSI C63.4:2014; FCC MP-5 (February 1986)-to 18000 MHz
4electrical
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited PARKER HANNIFIN CHOMERICS TEST SERVICES – WOBURN, MA Woburn, MA for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of June 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1980.01 Valid to June 30, 2026

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

84 Dragon Court, Woburn, MA, 01801, US

42.47926, -71.15228

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.