Intertek Testing Services NA
4341 State Street, Suite 100, 13153, Skaneateles Falls, NY, United States
Visit website- Accredited standards
- 40
- A2LA certificate
- 1
- Sites in our directory
- 4
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 40 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60601 series15
IEC 60601-1-1
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-1-4
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-2-25
IEC 60601-2-27
IEC 60601-2-30
IEC 60601-2-38
IEC 60601-2-46Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables
IEC 60601-2-47
IEC 60601-2-49
IEC 60601-2-51
IEC 60601-2-52
IEC9
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 62304
IEC 62366-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 80601-2-30Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
IEC 80601-2-49
IEC 61326 series7
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
ISO3
ISO 10535Assistive products - Hoists for the transfer of persons - Requirements and test methods
ISO 80601-2-56Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
UL 62368-1
UL 60601-1 (Ed. 1); CSA C22.2.60601.1; IEC/EN 60601-1 (Ed. 2 + Am 1 + Am 2); IEC/EN 60601-1-1 (Ed. 1 + Am 1, Ed. 2); IEC/EN 60601-1-4 (Ed. 1 + Am 1); IEC 60601-1 (Ed. 3, Ed. 3 + Am 1, Ed. 3 + Am1 + Am 2); ANSI/AAMI ES60601-1:2005 + C1:2009 + A2:2010; ANSI AAMI ES60601-1:2005/(R)2012 AND A1:2012; C1:2009/(R)2012 and A2:2010/(R)2012; ANSI AAMI ES60601-1:2005/(R)2012 AND A1:2012; C1:2009/(R)2012 and A2:2010/(R)2012 / A2:2021; IEC 62366-1 (Ed. 1 + Am 1); IEC/EN 60601-1-6 (Ed. 1, Ed. 2, Ed. 3 + Am 1 + Am 2); IEC/EN 62366 (Ed. 1 + Am 1); IEC/EN 62304 (Ed. 1 + Am 1); IEC/EN 60601-1-8 (Ed. 2 + Am 1 + Am 2); ANSI AAMI IEC 60601-1-8:2006 and A1:2012; IEC/EN 60601-1-11 (Ed. 1, Ed. 2 + Am 1); ANSI AAMI HA60601-1-11:2015 + A1:2021; IEC/EN 60601-2-25 (Ed. 1 + Am 1, Ed. 2); ANSI/AAMI/IEC 60601-2-25:2011/(R)2016; IEC/EN 60601-2-27 (Ed. 1, Ed. 2, Ed. 3); ANSI/AAMI/IEC 60601-2-27:2011(R)2016; IEC/EN 80601-2-30 (Ed. 1 + Am 1, Ed. 2); IEC/EN 60601-2-30 (Ed. 1, Ed. 2); IEC/EN 60601-2-46 (Ed. 1, Ed. 2, Ed. 3, Ed. 4); IEC/EN 60601-2-47 (Ed. 1, Ed. 2); IEC/EN 60601-2-49 (Ed. 1, Ed. 2); IEC/EN 80601-2-49; IEC/EN 60601-2-51 (Ed. 1); IEC/EN 60601-2-52 (Ed. 1 + Am 1)
IEC/EN 60601-2-38; ISO 80601-2-56; ISO 80601-2-61; ISO 10535:2006; ISO 10535:2021; ANSI AAMI IEC 80601-2-30:2009&A1:2013 (R2016); ANSI AAMI IEC 80601-2-30:2018; ANSI AAMI HA60601-1-11:2015; IEC 60601-1-11:2015 + A1 2020; IEC/EN 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; CISPR 11; CISPR 11:2003; CISPR 11:2009+A1:2010; CISPR 11:2015+A1:2016+A2:2019; EN 55011; EN 55011:2009; EN 55011:2016+A1:2017+A11:2020; AS CISPR 11; AS CISPR 11:2017+A1:2020; KS C 9811; KS C 9811:2019; CAN/CSA CISPR 11; EN 55022; AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; 47 CFR, FCC Part 15B; ICES-001; ICES-003; IEC 60601-1-2; ANSI AAMI IEC 60601-1-2:2014; KS C IEC 606061-1-2:2012; EN 60601-1-2; EN 60601-1-2:2001; EN 60601-1-2:2001+A1:2006; EN 60601-1-2:2007; EN 60601-1-2:2015; EN 60601-1-2:2015+A1:2021; AIM 7351731; AIM 7351731:2021 Rev 3.0; CISPR 32; EN 55032; EN 55032:2015; EN 55032:2015+A1:2020; KS C 9832; AS/NZS CISPR 32; AS/NZS CISPR 32:2015; AS/NZS CISPR 32:2015+A1:2020; VCCI-CISPR 32:2016; SI 961 Part 32; IEC 61000-3-2; IEC 61000-3-2:2000; IEC 61000-3-2:2005+A1:2008+A2:2009; IEC 61000-3-2:2018; IEC 61000-3-2:2018+A1:2020; EN 61000-3-2; EN 61000-3-2:2006; EN 61000-3-2:2006+A1:2009+A2:2009; KS C 9610-3-2; KS C 9610-3-2:2023
IEC 61326-1; IEC 61326-1 (Ed. 1, Ed. 2, Ed. 3); EN 61326-1; EN 61326-1:2006; EN 61326-1:2013; EN IEC 61326-1; EN IEC 61326-1:2021; IEC 61326-2-1; IEC 61326-2-1 (Ed. 1, Ed. 2, Ed. 3); EN 61326-2-1; EN 61326-2-1:2006; EN 61326-2-1:2013; IEC EN 61326-2-2; IEC EN 61326-2-2:2020; IEC 61326-2-2:2020; EN 61326-2-2:2013; IEC EN 61326-2-3; IEC EN 61326-2-3:2020; IEC 61326-2-3:2020; IEC 61326-2-3:2013; IEC/EN 61326-2-4; EN IEC 61326-2-4:2021; IEC 61326-2-4:2020; EN 61326-2-4:2013; IEC/EN 61326-2-5; EN IEC 61326-2-5:2021; IEC 61326-2-5:2020; EN 61326-2-5:2013; IEC EN 61326-2-6; IEC 61326-2-6:2021; IEC 61326-2-6:2020; EN 61326-2-6:2013; ANSI C63.27:2017; ANSI C63.27:2021; 47 CFR, FCC Part 18; IEC 60529; IEC 60068-2-64; IEC 60068-2-27
ANSI C63.4:2014; FCC MP-5:1986
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1350.04
The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1350.04
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UL 60601-1 (Ed. 1); CSA C22.2.60601.1; IEC/EN 60601-1 (Ed. 2 + Am 1 + Am 2); IEC/EN 60601-1-1 (Ed. 1 + Am 1, Ed. 2); IEC/EN 60601-1-4 (Ed. 1 + Am 1); IEC 60601-1 (Ed. 3, Ed. 3 + Am 1, Ed. 3 + Am1 + Am 2); ANSI/AAMI ES60601-1:2005 + C1:2009 + A2:2010; ANSI AAMI ES60601-1:2005/(R)2012 AND A1:2012; C1:2009/(R)2012 and A2:2010/(R)2012; ANSI AAMI ES60601-1:2005/(R)2012 AND A1:2012; C1:2009/(R)2012 and A2:2010/(R)2012 / A2:2021; IEC 62366-1 (Ed. 1 + Am 1); IEC/EN 60601-1-6 (Ed. 1, Ed. 2, Ed. 3 + Am 1 + Am 2); IEC/EN 62366 (Ed. 1 + Am 1); IEC/EN 62304 (Ed. 1 + Am 1); IEC/EN 60601-1-8 (Ed. 2 + Am 1 + Am 2); ANSI AAMI IEC 60601-1-8:2006 and A1:2012; IEC/EN 60601-1-11 (Ed. 1, Ed. 2 + Am 1); ANSI AAMI HA60601-1-11:2015 + A1:2021; IEC/EN 60601-2-25 (Ed. 1 + Am 1, Ed. 2); ANSI/AAMI/IEC 60601-2-25:2011/(R)2016; IEC/EN 60601-2-27 (Ed. 1, Ed. 2, Ed. 3); ANSI/AAMI/IEC 60601-2-27:2011(R)2016; IEC/EN 80601-2-30 (Ed. 1 + Am 1, Ed. 2); IEC/EN 60601-2-30 (Ed. 1, Ed. 2); IEC/EN 60601-2-46 (Ed. 1, Ed. 2, Ed. 3, Ed. 4); IEC/EN 60601-2-47 (Ed. 1, Ed. 2); IEC/EN 60601-2-49 (Ed. 1, Ed. 2); IEC/EN 80601-2-49; IEC/EN 60601-2-51 (Ed. 1); IEC/EN 60601-2-52 (Ed. 1 + Am 1) | - | - |
| 2 | IEC/EN 60601-2-38; ISO 80601-2-56; ISO 80601-2-61; ISO 10535:2006; ISO 10535:2021; ANSI AAMI IEC 80601-2-30:2009&A1:2013 (R2016); ANSI AAMI IEC 80601-2-30:2018; ANSI AAMI HA60601-1-11:2015; IEC 60601-1-11:2015 + A1 2020; IEC/EN 62368-1; UL 62368-1; CSA C22.2 No. 62368-1; CISPR 11; CISPR 11:2003; CISPR 11:2009+A1:2010; CISPR 11:2015+A1:2016+A2:2019; EN 55011; EN 55011:2009; EN 55011:2016+A1:2017+A11:2020; AS CISPR 11; AS CISPR 11:2017+A1:2020; KS C 9811; KS C 9811:2019; CAN/CSA CISPR 11; EN 55022; AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; 47 CFR, FCC Part 15B; ICES-001; ICES-003; IEC 60601-1-2; ANSI AAMI IEC 60601-1-2:2014; KS C IEC 606061-1-2:2012; EN 60601-1-2; EN 60601-1-2:2001; EN 60601-1-2:2001+A1:2006; EN 60601-1-2:2007; EN 60601-1-2:2015; EN 60601-1-2:2015+A1:2021; AIM 7351731; AIM 7351731:2021 Rev 3.0; CISPR 32; EN 55032; EN 55032:2015; EN 55032:2015+A1:2020; KS C 9832; AS/NZS CISPR 32; AS/NZS CISPR 32:2015; AS/NZS CISPR 32:2015+A1:2020; VCCI-CISPR 32:2016; SI 961 Part 32; IEC 61000-3-2; IEC 61000-3-2:2000; IEC 61000-3-2:2005+A1:2008+A2:2009; IEC 61000-3-2:2018; IEC 61000-3-2:2018+A1:2020; EN 61000-3-2; EN 61000-3-2:2006; EN 61000-3-2:2006+A1:2009+A2:2009; KS C 9610-3-2; KS C 9610-3-2:2023 | - | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1350.04) Revised 08/14/2025 Page 3 of 5
Tests:
Standard(s) 1,2:
Flicker and Fluctuations
IEC 61000-3-3; IEC 61000-3-3:2002;
IEC 61000-3-3:2008; IEC 61000-3-3:2013;
IEC 61000-3-3:2013+A1:2017;
IEC 61000-3-3:2013+A1:2021; EN 61000-3-3;
EN 61000-3-3:2013; KS C 9610-3-3;
KS C 9610-3-3:2023
Immunity
Electrostatic Discharge IEC 61000-4-2; IEC 61000-4-2:2001;
IEC 61000-4-2:2008; EN 61000-4-2; EN 61000-4-2:2009;
KS C 9610-4-2; KS C 9610-4-2:2022
Radiated Immunity IEC 61000-4-3; IEC 61000-4-3:2002;
IEC 61000-4-3:2006+A1:2007+A2:2010;
IEC 61000-4-2:2020; EN 61000-4-3; EN 61000-4-3:2006;
EN 61000-4-3:2006+A1:2008+A2:2010; KS C 9610-4-3;
KS C 9610-4-3:2022
Electrical Fast Transient/Burst
IEC 61000-4-4; IEC 61000-4-4:2004;
IEC 61000-4-4:2012; IEC 61000-4-5:2004+A1:2010;
EN 61000-4-4; EN 61000-4-4:2012; KS C 9610-4-4;
KS C 9610-4-4-:2020
Surge Immunity
IEC 61000-4-5; IEC 61000-4-5:2001;
IEC 61000-4-5:2005; IEC 61000-4-5:2014+A1:2017;
EN 61000-4-5; EN 61000-4-5:2006;
EN 61000-4-5:2014+A1:2017; KS C 9610-4-5;
KS C 9610-4-5:2023
Conducted Immunity
IEC 61000-4-6; IEC 61000-4-6:2003;
IEC 61000-4-6:2003+A1:2004+A2:2006;
IEC 61000-4-6:2013; IEC 61000-4-6:2023;
EN 61000-4-6; EN 61000-4-6:2014; EN 61000-4-6:2023;
KS C 9610-4-6; KS C 9610:2020
Power Frequency Magnetic Field Immunity
IEC 61000-4-8; IEC 61000-4-8:1993+A1:2000;
IEC 61000-4-8:2009; EN 61000-4-8; EN 61000-4-8:2010;
KS C 9610-4-8; KS C 9610-4-8:2022
Voltage Dips, Short Interruptions and Line Voltage
Variations
IEC 61000-4-11; IEC 61000-4-11:2004;
IEC 61000-4-11:2004+A1:2017; IEC 61000-4-11:2020;
EN 61000-4-11; EN 61000-4-11:2004;
EN 61000-4-11:2004+A1:2017; KS C 9610-4-11;
KS C 9610-4-11:2020
Flicker and Fluctuations IEC 61000-3-3; KS C 9610-3-3; KS C 9610-3-3 | ||
| 4 | IEC 61326-1; IEC 61326-1 (Ed. 1, Ed. 2, Ed. 3); EN 61326-1; EN 61326-1:2006; EN 61326-1:2013; EN IEC 61326-1; EN IEC 61326-1:2021; IEC 61326-2-1; IEC 61326-2-1 (Ed. 1, Ed. 2, Ed. 3); EN 61326-2-1; EN 61326-2-1:2006; EN 61326-2-1:2013; IEC EN 61326-2-2; IEC EN 61326-2-2:2020; IEC 61326-2-2:2020; EN 61326-2-2:2013; IEC EN 61326-2-3; IEC EN 61326-2-3:2020; IEC 61326-2-3:2020; IEC 61326-2-3:2013; IEC/EN 61326-2-4; EN IEC 61326-2-4:2021; IEC 61326-2-4:2020; EN 61326-2-4:2013; IEC/EN 61326-2-5; EN IEC 61326-2-5:2021; IEC 61326-2-5:2020; EN 61326-2-5:2013; IEC EN 61326-2-6; IEC 61326-2-6:2021; IEC 61326-2-6:2020; EN 61326-2-6:2013; ANSI C63.27:2017; ANSI C63.27:2021; 47 CFR, FCC Part 18; IEC 60529; IEC 60068-2-64; IEC 60068-2-27 | - | - |
| 5 | ANSI C63.4:2014; FCC MP-5:1986 | - | to 40000 MHz |
| 6 | ISO/IEC 17025:2017; A2LA - R256 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
3 other sites in this organization
Labs with overlapping accredited scope in United States
- Eurofins Electrical and Electronic Testing NALittleton, MA · ~407 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- DEKRA CertificationSterling, VA · ~451 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- Bay Area ComplianceSunnyvale, CA · ~3,869 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- Dayton T. BrownBohemia, NY · ~371 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- TUV Rheinland of North AmericaBoxborough, MA · ~407 kmA2LAShares 1 accredited test methodANSI C63.4:2014