DEKRA Certification
405 Glenn Drive, Suite 12, 20164, Sterling, VA, United States
Visit website- Accredited standards
- 55
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 55 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI21
ETSI EN 301 360
ETSI EN 301 428
ETSI EN 301 441
ETSI EN 301 443
ETSI EN 301 444
ETSI EN 301 459
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-12
ETSI EN 301 489-17
ETSI EN 301 489-19
Show all 21
ETSI EN 301 489-20
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-51
ETSI EN 301 489-52
ETSI EN 301 908-1
ETSI EN 302 186
ETSI EN 302 571
ETSI EN 303 980
IEC 61000 series8
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
KS C 9610-3-3national version with changes
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion+1 national
Limits written next to it
EN 61000-4-8(excluding short duration mode)
IEC 61000-4-8(excluding short duration mode)
National versions in the same scope
KS C 9610-4-8national version with changes
IEC7
IEC 60065
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+2 national
National versions in the same scope
AS/NZS 62368.1national version with changes
CNS 15598-1identical to it
IEC 62368-3
ISO5
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic dischargeExclusion
Limits written next to it
Electrostatic Discharge (ESD) ISO 10605 (excluding clause 10 vehicle test method)
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methodsExclusion
Limits written next to it
Bulk Current Injection (BCI) ISO 11452-4 (excluding TWC test method)
ISO 11452-4 (2011, 2020) (excluding TWC Method)
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
KS C 9811national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
KS C 9815national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CNS 15936identical to it
KS C 9832national version with changes
IEC 60335 series3
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-14
IEC 60335-2-64
IEC 61851 series3
IEC 61851-21-1
IEC 61851-21-2
IEC 61851-22Some clauses
Limits written next to it
EN 61851-22 (clause 11.3 EMC only)
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50270
EN 50498Electromagnetic compatibility (EMC) - Product family standard for aftermarket electronic equipment in vehicles
FCC PART 15Radio Frequency Devices
UL 62368-1
ETSI EN 301 908-1; ETSI EN 301 908-1 V15.2.1 (2023-01); SANS 301908-1; SANS 301908-1:2015; ETSI TS 134.124; 3GPP TS 34.124; ETSI EN 303 980; EN 303 980 V1.3.1 (2022-10); ETSI EN 302 186; ETSI EN 302 186 V2.2.1 (2021-05); ETSI EN 301 428; ETSI EN 301 428 V2.1.2 (2017-05); ETSI EN 301 441; ETSI EN 301 441 V2.1.1 (2016-06); ETSI EN 301 443; ETSI EN 301 443 V2.1.1 (2016-05); ETSI EN 301 444; ETSI EN 301 444 V2.2.1 (2021-04); ETSI EN 301 459; ETSI EN 301 459 V2.1.1 (2016-05); ETSI EN 301 360; ETSI EN 301 360 V2.1.1 (2016-05); ETSI EN 302 571; ETSI EN 302 571 V2.1.1 (2017-02); Taiwan - Radio LP0002 (2024); PLMN ALL (2023) (Only PLMN01); PLMN ALL (2023) (Only PLMN08); PLMN ALL (2023) (Only PLMN10); KS X 3123; KS X 3142
EN 50270; EN 50270:2015/AC:2016-08; EN 301 489-1; ETSI EN 301 489-1 V2.2.3 (2019-11); KS X 3124; SANS 301489-1; EN 301 489-3; ETSI EN 301 489-3 V2.3.2 (2023-01); KS X 3125; SANS 301489-3; EN 301 489-5; ETSI EN 301 489-5 V2.3.1 (2025-07); KS X 3127 ; SANS 301489-5; ETSI EN 301 489-12; ETSI EN 301 489-12 V3.2.1 (2021-11); EN 301 489-17; ETSI EN 301 489-17 V3.3.1 (2024-09); KS X 3126; SANS 301489-17; EN 301 489-19; ETSI EN 301 489-19 V2.2.1 (2022-09); SANS 301489-19; ETSI EN 301 489-20; ETSI EN 301 489-20 V2.2.1 (2021-11); EN 301 489-33; ETSI EN 301 489-33; ETSI EN 301 489-33 V2.2.1 (2019-04); EN 301 489-34; ETSI EN 301 489-34; ETSI EN 301 489-34 V2.1.1 (2019-04); EN 301 489-51; ETSI EN 301 489-51; ETSI EN 301 489-51 V2.1.1 (2019-04); EN 301 489-52; ETSI EN 301 489-52; ETSI EN 301 489-52 V1.3.1 (2024-11); KS C 9995; KS X 3129; CNS 15936 (2016); CNS 13803 (2018); CISPR 25 (2002, 2008); CISPR 25 (2016, 2021); SAE J1113-41; ISO 7637-2; ISO 7637-2 (2004, 2011); SAE J1113-11; ISO 7637-3; ISO 7637-3 (2007, 2016); SAE J1113-12; ISO 10605; ISO 10605:2023; ISO 10605 (2001); ISO 10605 (2008)
EN 61000-3-2; EN IEC 61000-3-2:2019+A1:2021+A2:2024; IEC 61000-3-2; IEC 61000-3-2:2018+AMD1:2020+AMD2:2024 (CSV); SANS 61000-3-2; SANS 61000-3-2:2009 (Edition 3.2); KS C 9610-3-2; KS C 9610-3-2:2023; EN 61000-3-3; EN IEC 61000-3-3:2013+A1:2019+A2:2021; IEC 61000-3-3; IEC 61000-3-3:2013+AMD1:2017+AMD2:2021 (CSV); SANS 61000-3-3; KS C 9610-3-3; KS C 9610-3-3:2023; EN 61000-4-2; EN IEC 61000-4-2:2009 + A1:2019; IEC 61000-4-2; IEC 61000-4-2:2008 + AMD1:2010 + AMD2:2018 (CSV); SANS 61000-4-2; KS C 9610-4-2; KS C 9610-4-2:2023; EN 61000-4-3; EN IEC 61000-4-3:2020; IEC 61000-4-3; IEC 61000-4-3:2020; SANS 61000-4-3; KS C 9610-4-3; KS C 9610-4-3:2023; EN 61000-4-4; EN IEC 61000-4-4:2012+A1:2021; IEC 61000-4-4; IEC 61000-4-4:2012+AMD1:2021; SANS 61000-4-4; KS C 9610-4-4; KS C 9610-4-4:2023; EN 61000-4-5; EN IEC 61000-4-5:2014+A1:2017; IEC 61000-4-5; IEC 61000-4-5:2014+AMD1:2017; SANS 61000-4-5; KS C 9610-4-5; KS C 9610-4-5:2023; EN 61000-4-6; EN IEC 61000-4-6:2014+A1:2017; IEC 61000-4-6; IEC 61000-4-6:2013+AMD1:2017; SANS 61000-4-6; KS C 9610-4-6; KS C 9610-4-6:2023; EN 61000-4-8(excluding short duration mode); EN IEC 61000-4-8:2010; IEC 61000-4-8(excluding short duration mode); IEC 61000-4-8:2009; SANS 61000-4-8; KS C 9610-4-8; KS C 9610-4-8:2023
CTIA Test Plan for Wireless Device Over-the-Air Performance3; Method of Measurement for Radiated RF Power and Receiver Performance, Version 4.0.5; CTIA Test Plan for Evaluation of Wi-Fi Mobile Converged Devices, Version 2.23; 3GPP TS 34.114; WINNF-TS-0122; CBRSA-TS-9001; GSM Association Official Document TS.11; IEC 60730-1; IEC 60730-1:2022; EN IEC 60730-1:2022; IEC 62368-1; IEC 62368-1:2014 Ed. 2; IEC 62368-1:2014 (Ed. 2.0) + COR1:2015 + COR2:2015; IEC 62368-1:2023; EN 62368-1; EN 62368-1:2014 (2nd Ed.); EN 62368-1:2014 + AC:2015 + AC:2017-03 + A11:2017; EN IEC 62368-1:2024 + A11:2024; IEC 62368-3:2017; IEC 60950-1:2005+A1:2009+A2:2013 (Ed. 2.2); IEC 60065:2014 (Ed. 8.0); IEC 61010-1; IEC 61010-1:2010 + Amd 1:2016 + COR 1:2019; EN 61010-1:2010 + A1:2019 + AC:2019-04; IEC 60335-1; IEC 60335-1:2020 + A1:2025; EN IEC 60335-1:2023 + A11:2023; IEC 60335-2-14; IEC 60335-2-14:2025 (Ed. 7.0); EN IEC 60335-2-14:2023 + A1:2023 + A11:2023; IEC 60335-2-64; IEC 60335-2-64:2021 + A1:2024 (Ed. 4.1); EN 60335-2-64:2000 + A1:2002
ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012, C1:2009/(R)2012 & A2:2010/(R)2012; IEC 60601-1-2 Edition 4.1 2020-09; ANSI AAMI IEC 60601-1-2:2014
CAN/CSA-E60730-1:13; CSA E60730-1:25; CSA C22.2 No. 62368-1:19; CSA C22.2 No. 62368-1:25; CSA C22.2 No. 62368-1:14 (R2019); CAN/CSA C22.2 No. 61010-1-12:2012 (R2022), UPD1:2015, UPD2:2016, A1:2018 (incl. COR1:2019), UPD3:2023; UL 60730-1; UL 60730-1:2024; UL 62368-1; UL 62368-1:2019; UL 62368-1:2025; UL 61010-1; UL 61010-1, 3rd Edition, issue May 11, 2012; UL 60335-1; UL 60335-1, Ed. 6, 2016-10-31; UL 60335-2-14; UL 60335-2-14, Edition 4 (2003-04-24); UNE EN 62368-1; UNE-EN IEC 62368-1:2014 (+ AC/As + A11:2017); UNE-EN IEC 62368-1:2020 + A11:2020 (+ AC:2020-05); UNE-EN IEC 62368-1:2024 + A11:2024; DS/EN 62368-1; DS/EN IEC 62368-1:2020 + A11:2020; DS/EN IEC 62368-1:2024 + A11:2024; CEI EN 62368-1; CEI EN IEC 62368-1:2020-09; CEI EN IEC 62368-1:2024; J62368-1; J62368-1:2020; J62368-1:2023; JIS C 1010-1:2019; SASO-IEC-62368-1; SASO IEC 62368-1:2020; AS/NZS 62368.1; AS/NZS 62368.1:2022; NMX-I-62368-1; NMX-I-62368-1-NYCE-2020; NOM-001-SCFI-2018; NMX-I-60950-1-NYCE-2015; NMX-I-60065-NYCE-2015; SANS 62368-1; SANS 62368-1:2020; SANS/IEC 62368-1:2020 (Ed. 2); SANS 60065:2015; SANS 60950-1:2014; CNS 15598-1; CNS 15598-1:2020
ISO 11452-2; SAE J1113-21; ISO 11452-4 (2005); ISO 11452-4 (2011, 2020); SAE J113-4; ISO 11452-4:2020; UNECE Regulation 10; IEC 61851-21-1; EN 61851-21; IEC 61851-21-2; EN 61851-22; EN 50498; SAE J1849; KS C 9990; CFR 47 FCC, Part 15; ANSI C63.10-2020; ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024; FCC KDB 905462 D02 [v02]; RSS-GEN; RSS-210; RSS-213; RSS-216; RSS-220; RSS-247; RSS-248; IFT-008-2015; NOM-208-SCFI-2016; IFT-016-2024; IFT-017-2023; ARIB-STD-T66; CFR 47 FCC Parts 22; CFR 47 FCC Parts 24; CFR 47 FCC Parts 25; CFR 47 FCC Parts 27; ANSI C63.26:2015; CFR 47 FCC Parts 90; CFR 47 FCC Parts 95; CFR 47 FCC Parts 97; CFR 47 FCC Parts 101; CFR 47 Part 96
CFR 47 FCC Part 15 Subpart B (ANSI C63.4:2014) ; ANSI C63.4; CFR 47 FCC Part 18 (MP-5:1986); ICES-001; ICES-003; CISPR 32; CISPR 32:2015 + AMD1:2019 CSV (Ed. 2.1); EN 55032 ; EN 55032:2015 + A1:2020 (+A11) ; CISPR 112; EN 550112; EN IEC 55011:2025; BS EN IEC 55011:2025 ; CISPR 15; CISPR 15:2018; CISPR 15:2018 + AMD1:2024 (Ed. 9.1); EN 55015; EN IEC 55015:2019 + A11:2020; AS/NZS CISPR 32:2015 Amd 1:2019 ; KS C 9832; KS C 9811; KS C 9815; KS C 9832:2024; KS C 9811:2019; KS C 9815:2023; SANS 2332; SANS 2332:2017 (Ed. 1.00) ; CNS 15936; CNS 15936 (2016, excluding Annex H); CNS 13803; CNS 13803:2018
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10-2020; FCC KDB 905462 D02 (v02); ANSI C63.10:2013; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
13 lines
ISO/IEC 17025
Active2764.01
The scope document we hold says it was valid until 2026-10-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Eurofins Electrical and Electronic Testing NALittleton, MA · ~633 kmA2LAShares 3 accredited test methodsANSI C63.4:2014IEC 62368-1UL 62368-1
- HCT AmericaMilpitas, CA · ~3,852 kmA2LAShares 3 accredited test methodsANSI C63.4ANSI C63.4:2014EN 61000-3-2
- Clark Dynamic Testing Laboratory, Inc.Jefferson Hills, PA · ~260 kmA2LAShares 2 accredited test methodsANSI C63.4ANSI C63.4:2014
- Intertek Testing Services NASkaneateles Falls, NY · ~451 kmA2LAShares 2 accredited test methodsANSI C63.4:2014UL 62368-1
- TUV Rheinland of North AmericaBoxborough, MA · ~629 kmA2LAShares 2 accredited test methodsANSI C63.4ANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.