Synergy Health Radeberg
Juri-Gagarin-Straße 15, 01454, Radeberg, Germany
- Accredited standards
- 11
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 11 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO4
ISO 11137-1Sterilization of health care products - Radiation - Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices
ISO 11137-2Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose
ISO 13004Sterilization of health care products - Radiation - Substantiation of selected sterilization dose: Method VDmaxSD
ISO 14937Sterilization of health care products - General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 11737 series3
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products
ISO 11737-2Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
ISO 11737-3Sterilization of health care products - Microbiological methods - Part 3: Bacterial endotoxin testing
USP3
USP 38
USP 85
USP 161
Other standards1
EN 17141Cleanrooms and associated controlled environments - Biocontamination control
DIN EN ISO 11737-2; DIN EN ISO 11737-1; DIN EN ISO 13004; DIN EN ISO 11137-1; DIN EN ISO 11137-2; DIN EN ISO 13485 : 2021; ISO 11737-3; Ph. Eur. 2.6.14; USP <85>; USP <161>; ANSI/AAMI ST72; Ph.Eur. 5.1.10; DIN EN 17141
DIN EN 17141; DIN EN ISO 11137-1; DIN EN ISO 11137-2; DIN EN ISO 11737-1; DIN EN ISO 11737-2; ISO 11737-3; DIN EN ISO 13004; DIN EN ISO 14937
DIN EN 17141 : 2021-02; Ph. Eur. 8, 2.6.14; Ph. Eur. 8, 5.1.10; USP 38 <85>; USP 38 <161>; ANSI/AAMI ST72:2019; AA 1000_001_00v16; AA 1000_002_00v18; AA 1000_010_00v16; AA 1000_027_00v05
Read from the scope as published by DAKKS. Register refreshed 2026-10-23.
Scope as published by DAKKS
4 lines
ISO/IEC 17025
ActiveD-PL-20594-01-01
Accredited scope, certificate D-PL-20594-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Medizinprodukten; Sterilisationsverfahren; Umgebungsüberwachung | - |
| 2 | DIN EN ISO 11737-2; DIN EN ISO 11737-1; DIN EN ISO 13004; DIN EN ISO 11137-1; DIN EN ISO 11137-2; DIN EN ISO 13485 : 2021; ISO 11737-3; Ph. Eur. 2.6.14; USP <85>; USP <161>; ANSI/AAMI ST72; Ph.Eur. 5.1.10; DIN EN 17141 | Medizinprodukte; Luft | - |
| 3 | DIN EN 17141; DIN EN ISO 11137-1; DIN EN ISO 11137-2; DIN EN ISO 11737-1; DIN EN ISO 11737-2; ISO 11737-3; DIN EN ISO 13004; DIN EN ISO 14937 | Oberflächen | - |
| 4 | DIN EN 17141 : 2021-02; Ph. Eur. 8, 2.6.14; Ph. Eur. 8, 5.1.10; USP 38 <85>; USP 38 <161>; ANSI/AAMI ST72:2019; AA 1000_001_00v16; AA 1000_002_00v18; AA 1000_010_00v16; AA 1000_027_00v05 | Reinräume und zugehörige Reinraumbereiche; Umgebungsproben; Luftkeimzahl; Oberflächenproben | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.