Euclid Metrology

Cedar Rapids, IA, United States

Visit website
A2LA 5873.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 5873.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5873.01) 11/25/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EUCLID METROLOGY INC. 126 29 th Drive SE, Suite A Cedar Rapids, IA 52403 Andy Livin Phone: 319 538 5601 CALIBRATION Valid To: August 31, 2026 Certificate Number: 5873.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Calipers3 ─ Dial Digital Up to 12 in Up to 12 in 660 µin 430 µin Gage blocks & ring gages Linear Indicators3 ─ Dial and Test Up to 6 in: 0.0001 in Resolution 0.0005 in Resolution 0.0010 in Resolution 58 µin 290 µin 580 µin Gage blocks Gage Blocks Up to 6 in (7.4 + 0.5L) µin Pratt & Whitney Labmaster™, gage blocks Pins and Plugs Up to 6 in 16 µin Pratt & Whitney Labmaster™, gage blocks Thread Wires – Diameter (4 to 80) TPI 9.5 µin Pratt & Whitney Labmaster™, gage blocks
to 12 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5873.01) 11/25/2024 Page 2 of 2 Parameter/Equipment Range CMC2, 4 (±) Comments Cylindrical Rings – Plain Up to 6 in 30 µin Pratt & Whitney Labmaster™, gage blocks Micrometers3 Up to 12 in (53 + 3.0L) µin Gage blocks Thread Plugs Up to 6 in 90 µin Pratt & Whitney Labmaster™, gage blocks, thread wires Thread Rings – Pitch Up to 6 in 350 µin Setting plugs (Class X) ___________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due t o the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
to 6 in
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.