Japan

Microwave Factory Calibration Laboratory

815-1, Tatemachi, Hachiouji-shi, Tokyo, 193-0985, Japan, Tokyo, Japan

Visit website
A2LA 3577.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 3577.01 · 6 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3577.01) 06/10/2024 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MICROWAVE FACTORY CALIBRATION LABORATORY 815-1, Tatemachi, Hachiouji-shi, Tokyo 193-0985 JAPAN Mr. Masanori Sakurai Phone: + 81 42 673 3535 sakurai@mwf.co.jp CALIBRATION Valid To: May 31, 2026 Certificate Number: 3577.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4, 5: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Measure (0 to 32.999) mV (33.000 to 77.999) mV (78.000 to 119.999) mV (120.00 to 329.99) mV (0.330 00 to 1.199 99) V (1.2000 to 11.9999) V (12.000 to 119.999) V (120.00 to 329.99) V 2.5 µV 77 µV/V 35 µV/V 24 µV/V 13 µV/V 11 µV/V 13 µV/V 14 µV/V Agilent 3458A
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3577.01) 06/10/2024 Page 2 of 5 Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Generate (0 to 32.9999) mV (33.000 to 77.999) mV (78.000 to 119.999) mV (120.000 to 329.999) mV (330.00 to 779.99) mV (0.780 00 to 3.299 99) V (3.3000 to 7.7999) V (7.8000 to 32.9999) V (33.000 to 77.999) V (78.000 to 329.999) V 2.8 µV 84 µV/V 40 µV/V 30 µV/V 15 µV/V 11 µV/V 14 µV/V 11 µV/V 18 µV/V 16 µV/V Fluke 5520A Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Resistance – Measure (0 to 11.9999) Ω (12.000 to 32.9999) Ω (33.000 to 119.999) Ω (120.00 to 1199.99) Ω (1.2000 to 11.9999) kΩ (12.000 to 119.999) kΩ (120.00 to 1100.00) kΩ 0.3 mΩ 86 µΩ/Ω 38 µΩ/Ω 18 µΩ/Ω 18 µΩ/Ω 18 µΩ/Ω 43 µΩ/Ω Agilent 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3577.01) 06/10/2024 Page 3 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (12.000 to 32.999) mV (33.000 to 119.999) mV (120.00 to 329.99) mV (0.330 00 to 1.199 99) V (1.2000 to 3.2999) V (3.3000 to 11.9999) V (12.000 to 32.999) V (33.000 to 119.999) V (120.00 to 329.99) V (0.600 00 to 1.199 99) V (1.2000 to 3.2000) V 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 100 Hz to 20 kHz 100 Hz to 20 kHz 0.031 % 0.021 % 0.025 % 0.017 % 0.025 % 0.017 % 0.038 % 0.033 % 0.057 % 0.039 % 0.11 % Agilent 3458A 100 mV range, SSM mode 1 V range, SSM mode 10 V range, SSM mode 100 V range, SSM mode 1000 V range, SSM mode 1 V range, ANA mode 10 V range, ANA mode AC Voltage – Generate (1.650 to 47.999) mV (48.000 to 119.99) mV (120.00 to 329.999) mV (330.00 to 779.99) mV (0.780 00 to 3.2999) V (3.3000 to 7.7999) V (7.8000 to 32.9999) V (33.000 to 329.999) V 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 0.032 % 0.028 % 0.018 % 0.027 % 0.019 % 0.027 % 0.019 % 0.021 % Fluke 5520A Test sources < 48 mV are obtained using a 200:1 custom attenuator driven by Fluke 5520A set for 200x the desired voltage, Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3577.01) 06/10/2024 Page 4 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Flatness – Measure (1 kHz Reference) (100 to 115) mV (1.00 to 1.15) V (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.0017 dB 0.0014 dB 0.0019 dB 0.0035 dB 0.0070 dB 0.026 dB 0.0015 dB 0.0013 dB 0.0019 dB 0.0035 dB 0.0070 dB 0.026 dB Agilent 3458A 100 mV range, SSM mode 1 V range, SSM mode AC Flatness – Generate (1 kHz Reference) (100 to 320) mV (1.00 to 3.20) V (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.0043 dB 0.0022 dB 0.0023 dB 0.0034 dB 0.0078 dB 0.018 dB 0.0028 dB 0.0020 dB 0.0022 dB 0.0029 dB 0.0058 dB 0.020 dB Fluke 5520A Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω Rsource ≈ 50 Ω II. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure 1 Hz to 10 MHz 0.18 µHz/Hz Agilent 53131 w/ opt 010 timebase ____________________________________________ 1 This laboratory offers commercial calibration service.
1 to 10000000 Hz
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3577.01) 06/10/2024 Page 5 of 5 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC Uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 This laboratory only offers commercial calibration services on API product families . The scope parameters, ranges and CMC uncertainties are specific to the API product families only. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
6ISO/IEC 17025:20 17; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

815-1, Tatemachi, Hachiouji-shi, Tokyo, 193-0985, Japan, Tokyo, JP

35.67686, 139.76389

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.