Shenzhen Huatongwei International Inspection Co.,
Building 7,Baiwang Idea Factory, No.1051,Songbai Road,Yangguang Community,Xili Subdistrict, Nanshan District, Shenzhen, 518000, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 113
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 113 standard numbers and the 44 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI51
ETSI EN 300 219
ETSI EN 300 296
ETSI EN 300 341
ETSI EN 300 373-1
ETSI EN 300 373-2
ETSI EN 300 373-3
ETSI EN 300 390
ETSI EN 300 392-2
ETSI EN 300 394-1
ETSI EN 300 396-2
ETSI EN 300 433
ETSI EN 300 698
Show all 51
ETSI EN 300 720
ETSI EN 301 025
ETSI EN 301 166
ETSI EN 301 178
ETSI EN 301 406
ETSI EN 301 489-1Exclusion
Limits written next to it
ETSI EN 301 489-1 (excluding section 9.6)
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-9
ETSI EN 301 489-13
ETSI EN 301 489-15
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-33
ETSI EN 301 489-52
ETSI EN 301 502
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 783
ETSI EN 301 843-1
ETSI EN 301 843-2
ETSI EN 301 843-5
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-3
ETSI EN 301 908-4
ETSI EN 301 908-5
ETSI EN 301 908-6
ETSI EN 301 908-7
ETSI EN 301 908-11
ETSI EN 301 908-13
ETSI EN 301 908-14
ETSI EN 301 908-15
ETSI EN 301 929
ETSI EN 302 561
ETSI EN 302 885
ETSI EN 303 402
ETSI EN 303 405
ETSI EN 303 609
ETSI EN 303 758
IEC 60601 series19
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-1-12
IEC 60601-2-2
IEC 60601-2-5
IEC 60601-2-10
IEC 60601-2-18
IEC 60601-2-22
IEC 60601-2-25
Show all 19
IEC 60601-2-27
IEC 60601-2-34
IEC 60601-2-37
IEC 60601-2-47
IEC 60601-2-50
IEC 60601-2-52
IEC 60601-2-57
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
ISO 80601 series8
ISO 80601-2-56Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement
ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment
ISO 80601-2-69Medical electrical equipment - Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment
ISO 80601-2-70Medical electrical equipment - Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipment
ISO 80601-2-72Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients
ISO 80601-2-74Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment
ISO 80601-2-79Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment
ISO 80601-2-80Medical electrical equipment - Part 2-80: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory insufficiency
IEC7
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 80601-2-30Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers
IEC 80601-2-60
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN4
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 55103-2
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
ETSI EN 300 219; ETSI EN 300 296; ETSI EN 300 390; ETSI EN 300 341; ETSI EN 301 166; ETSI EN 302 561; ETSI EN 303 758; ETSI EN 300 392-2; ETSI EN 300 394-1; ETSI EN 300 396-2; ETSI EN 300 433; ETSI EN 301 783; ETSI EN 303 405; ETSI EN 301 178; ETSI EN 301 929; ETSI EN 302 885; ETSI EN 300 720; ETSI EN 303 402; ETSI EN 301 025; ETSI EN 300 698; ETSI EN 300 373-1; ETSI EN 300 373-2; ETSI EN 300 373-3; ETSI EN 301 511; ETSI EN 301 502; ETSI EN 303 609; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-3; ETSI EN 301 908-4; ETSI EN 301 908-5; ETSI EN 301 908-6; ETSI EN 301 908-7; ETSI EN 301 908-11; ETSI EN301908-13; ETSI EN 301 908-14; ETSI EN 301 908-15; ETSI EN 301 406; AS/NZS 4268; AS/NZS 4355; AS/NZS 4771; AS/NZS 4365; AS/NZS 4295; AS/NZS 4768.1; AS/NZS 4768.2; AS/NZS 4768.3; AS/NZS ETSI EN 301 025; AS/NZS ETSI EN 301 178; AS/NZS ETSI EN 302 885; Article 2 Paragraph 1 Item 19; Article 2 Paragraph 1 Item 19-2; Article 2 Paragraph 1 Item 19-3; Article 2 Paragraph 1 Item 8; Article 2 Paragraph 1 Item 1-10; Article 2 Paragraph 1 Item 1-11; Article 2 Paragraph 1 Item 1-39; Article 2 Paragraph 1 Item 1-40; Article 2 Paragraph 1 Item (11)-3(XZ); Article 2 Paragraph 1 Item (11)-7(MW); Article 2 Paragraph 1 Item (11)-19; Article 2 Paragraph 1 Item 21-3
IEC/EN 61000-4-11; IEC 61000-4-29; EN 61000-4-29; ANSI/USEMCSC C63.27-2021; AAMI TIR69:2017/(R2020); IEC/EN 61000-4-39; IEC/EN 61000-6-1; IEC/EN 61000-6-2; CISPR 24; EN 55024; CISPR 35; EN 55035; IEC/EN 61547; EN IEC 61326-1; IEC 61326-1; EN 55103-2; CISPR 14-2; EN 55014-2; IEC/EN 60601-1-2; ANSI/AAMI IEC 60601-1-2; IEC/EN 61326-2-6; IEC TR 60601-4-2; EN 50130-4; EN 50121-4; EN 50121-3-2; IEC 61800-3; EN 61800-3; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-9; ETSI EN 301 489-13; ETSI EN 301 489-15; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-33; ETSI EN 301 489-52; ETSI EN 301 843-1; ETSI EN 301 843-2; ETSI EN 301 843-5; FCC CFR 47 FCC Part 15C; ANSI C63.10:2013; ANSI C63.10:2020; CFR47 FCC Part 15D; ANSI C63.17:2013; CFR47 FCC Part 15E; FCC KDB 905462 D02 (v02); CFR 47 FCC Part 15F
IEC 60601-2-27; IEC 60601-2-34; IEC 60601-2-37; IEC 60601-2-47; IEC 60601-2-50; IEC 60601-2-52; IEC 60601-2-52; IEC 60601-2-57; IEC 61010-1; IEC 60601-1; IEC 80601-2-30; IEC 80601-2-60; ISO 80601-2-56; ISO 80601-2-61; ISO 80601-2-69; ISO 80601-2-70; ISO 80601-2-72; ISO 80601-2-74; ISO 80601-2-79; ISO 80601-2-80; IEC 60601-2-22; IEC 60601-2-57; ISO 80601-2-72; ISO 80601-2-74; IEC TR 60601-4-2
ANSI/TIA-603-E; ANSI C63.26:2015; TIA-102.CAAA-E; ANSI AAMI ES60601-1:2005/(R)2012 & A1:2012 C1:2009/(R)2012 & A2:2010/(R)2012 (Cons. Text) [Incl. AMD2:2021]; ANSI AAMI HA60601-1-11:2015 [Including AMD1:2021]; IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-1-12 Edition 1.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-5 Edition 3.0 2009-07; IEC 60601-2-10 Edition 2.1 2016-04; IEC 60601-2-18 Edition 3.0 2009-08; IEC 60601-2-22 Edition 3.1 2012-10; IEC 60601-2-25 Edition 2.0 2011-10
ISO/IEC 17025:2017; CFR 47 FCC Part 15B (using ANSI C63.4:2014); FCC Part 18 (using FCC OST/MP-5-1986); CISPR 11; EN 55011; AS/NZS CISPR 11; CISPR 15; EN 55015; CISPR 32; EN 55032; VCCI V-3 (up to 6 GHz); ICES-003; ICES-005; IEC/EN 61000-6-3; IEC/EN 61000-6-4; IEC/EN 61000-3-2; IEC/EN 61000-3-3; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6; IEC/EN 61000-4-8
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
10 lines
ISO/IEC 17025
Active3902.01
The scope document we hold says it is valid until 2026-12-31.
Labs with overlapping accredited scope in China
- Dongguan New Testing Centre Co.,DongguanA2LAShares 3 accredited test methodsANSI C63.4:2014CISPR 11IEC 61010-1
- MRT Technology (Suzhou) Co.,Suzhou, JiangsuA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-ECISPR 11
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EIEC 61010-1
- Shenzhen CTL Testing Technology Co.,ShenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EIEC 61010-1
- Shenzhen HUAK Testing Technology Co.,ShenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-ECISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.