FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

SCHWENK Technologiezentrum GmbH & Co. KG

Altenburger Chaussee 3, 06406, Bernburg (Saale), Germany

DAKKS|D-PL-18748-01-00ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
29
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at SCHWENK Technologiezentrum GmbH & Co. KG?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-18748-01-00Active

Accredited standards

29

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN

EN 933-1Tests for geometrical properties of aggregates - Part 1: Determination of particle size distribution - Sieving method
As written on the certificate · Line 4 (DAKKS D-PL-18748-01-00)

öbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01

EN 933-4Tests for geometrical properties of aggregates - Part 4: Determination of particle shape - Shape index
As written on the certificate · Line 4 (DAKKS D-PL-18748-01-00)

öbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01

EN 1008Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-18748-01-00)

DIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008

EN 1542Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12504-1Testing concrete in structures - Part 1: Cored specimens - Taking, examining and testing in compression
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 12504-2Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 13286-2Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-18748-01-00)

DIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008

EN 13791Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 14488-1Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 14488-2Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 12390 series

EN 12390-2Testing hardened concrete - Part 2: Making and curing specimens for strength tests
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12390-3Testing hardened concrete - Part 3: Compressive strength of test specimens
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12390-5Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12390-6Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12390-7Testing hardened concrete - Part 7: Density of hardened concrete
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12390-8Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 12390-13Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-18748-01-00)

DIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStb

EN 12350 series

EN 12350-1Testing fresh concrete - Part 1: Sampling and common apparatus
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12350-4Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12350-5Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12350-6Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12350-7Testing fresh concrete - Part 7: Air content - Pressure methods
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 12350-8Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-18748-01-00)

DIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7

EN 1097 series

EN 1097-3Name not checked yet
As written on the certificate · Line 5 (DAKKS D-PL-18748-01-00)

DIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008

EN 1097-5Tests for mechanical and physical properties of aggregates - Part 5: Determination of the water content by drying in a ventilated oven
As written on the certificate · Line 5 (DAKKS D-PL-18748-01-00)

DIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008

EN 1097-6Tests for mechanical and physical properties of aggregates - Part 6: Determination of particle density and water absorption
As written on the certificate · Line 5 (DAKKS D-PL-18748-01-00)

DIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008

EN 932 series

EN 932-1Tests for general properties of aggregates - Part 1: Methods for sampling
As written on the certificate · Line 4 (DAKKS D-PL-18748-01-00)

öbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01

EN 932-2Tests for general properties of aggregates - Part 2: Methods for reducing laboratory samples
As written on the certificate · Line 4 (DAKKS D-PL-18748-01-00)

öbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01

EN 932-5Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-18748-01-00)

öbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01

Scope as published by DAKKS

5 lines
DAKKS

ISO/IEC 17025

Active

D-PL-18748-01-00

View scope

Accredited scope, certificate D-PL-18748-01-00

LineDisciplineMethodMatrixRange
1mechanicalDIN EN ISO/IEC 17025:2018; DIN EN ISO 9001Concrete-
2materialsDIN EN 1542; DIN EN 12350 -1; DIN EN 12350 -4; DIN EN 12350 -5; DIN EN 12350 -6; DIN EN 12350 -7; DIN EN 12350 -8; DIN EN 12390 -2; DIN EN 12390 -3; DIN EN 12390 -5; DIN EN 12390 -6; DIN EN 12390 -7Concrete-
3materialsDIN EN 12390 -8; DIN CEN/TS 12390 -9; DIN EN 12390 -13; DIN EN 12504 -1; DIN EN 12504 -2; DIN EN 13791; DIN EN 14488 -1; DIN EN 14488 -2; DAfStbhardened concrete; concrete in structures; sprayed concrete; Retarded concrete; Self-compacting concrete; Steel fibre concrete-
4materialsöbv -Richtlinie (directive) 2015-04; RILEM TC 117 -FDC 1997-04; RILEM TC 176 -IDC 2004-12; BAW leaflet „Frost testing“ (Freeze test) 2012-09; TP Beton -StB 10 2010; DIN EN 932 -1 1996-11; DIN EN 932 -2 1999-03; DIN EN 932 -5 2012-05; DIN EN 933 -1 2012-03; DIN EN 933 -4 2015-01Concrete-
5mechanicalDIN EN 1097 -3; DIN EN 1097 -5; DIN EN 1097 -6; DIN EN 13286 -2; DAfStb Alkali-Guideline; DIN EN 1008Aggregates-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Altenburger Chaussee 3, Bernburg (Saale), 06406, DE

51.79397, 11.73739

Open in Maps

Accreditation data refreshed from the DAKKS register on .