Microsep (Pty)
2 Saturn Crescent, Linbro Business Park, Sandton, 2196, South Africa, Sandton, South Africa
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3893.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 3893.01) 2/26/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
MICROSEP (PTY) LTD
2 Saturn Crescent
Linbro Business Park
Sandton, SOUTH AFRICA 2196
Shane Niemand Phone: 27 11 553 2300
CALIBRATION
Valid To: March 31, 2028 Certificate Number: 3893.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments4
Digital Self-Indicating
Weighing Instruments3
Up to 6.1 g
(6.1 to 52) g
(52 to 220) g
(220 to 520) g
520 g to 5.1 kg
(5.1 to 10.1) kg
(10.1 to 64.1) kg
(64.1 to 150) kg
(150 to 600) kg
(600 to 2000) kg
0.02 mg
0.09 mg
0.3 mg
0.7 mg
8 mg
30mg
0.8g
3.8 g
0.033 kg
0.15 kg
OIML class E2,
F1, F2, M1, M2,
ASTM class 1
mass pieces
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | to 2000 kg |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 3893.01) 2/26/2026 Page 2 of 2
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the uncertainty introduced by the i tem being calibrated, (e.g., resolution) must also
be considered and this, on its own, could result in the calibration uncertainty being larger than the CMC
uncertainty.
4 Technical Signatories – Freeman Baloyi, Keagan Buys, Kashin Devraj, Daniel Grobler, Duncan Hughes,
Gareth Lottering, Zandre Joubert, Berend Kruger, Shaun Rossouw, Refilwe Mosikidi
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
2 Saturn Crescent, Linbro Business Park, Sandton, 2196, South Africa, Sandton, ZA
-26.11129, 28.05121
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.