GMW Associates
955 Industrial Rd, 94070, San Carlos, CA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 4349.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4349.01) 2/11/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
GMW ASSOCIATES
955 Industrial Road
San Carlos, CA 94070
Sandro Renteria Phone: 650 802 8292
CALIBRATION
Valid To: March 31, 2028 Certificate Number: 4349.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Electrical – DC/Low Frequency
Parameter/Range5
Range
CMC2 (±)
Comments
DC Ratio Error3 – Current &
Voltage Output
(15 to 600) A
600 A to 11 kA
±10 % of Ratio Error
0.2 % of Ratio Error
0.1 % of Ratio Error
Calibration of DC
current transducers
using reference
transducer
comparison
method
AC Ratio Error3, 4 – Current &
Voltage Output
5 A to 2 kA & (5 to 100) Hz
(>2 to 8) kA & (5 to 100) Hz
5 A to 8 kA & (>100 to 400)
Hz
±10 % of Ratio Error
0.05 % of Ratio Error
0.1 % of Ratio Error
0.2 % of Ratio Error
Calibration of AC
current transducers
using reference
transducer
comparison method | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4349.01) 2/11/2026 Page 2 of 2
Parameter/Range5
Range
CMC2 (±)
Comments
AC Phase Displacement3 – Current
& Voltage Output
5 A to 8 kA & (5 to 100) Hz
5 A to 8 kA & (>100 to 400) Hz
±180°
0.09°
0.11°
Calibration of AC
current transducers
using reference
transducer
comparison method
________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 AC Current Range values are RMS (sinusoidal) values. Limited to 2 kA at 400 Hz.
5 The current range refers to the Transducer’s Nominal Current.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | 5 to 8000 A |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
GMW ASSOCIATES
San Carlos, CA
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 11th day of February 2026.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4349.01
Valid to March 31, 2028 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.