Register record

A2LACollected
921.01Active
921.02Active

Certificates and scope

2
A2LA

ISO/IEC 17025

Active

921.01

View scope

Accredited scope, certificate 921.01

DisciplineMethodMatrixRange
materialsIEC 61215-4.10; UL 61215-2-4.10; IEC 61730-2-10.31; UL 61730-2-10.31; ANSI/UL 1703-33; ULC/ORD C1703-01-5.15; UL 9703 33; IEC 61215-4.4; UL 61215-2-4.4; ANSI/UL 790; ANSI/UL 1703, Sections 16 and 31; ULC/ORD C1703-01-5.14; ANSI/UL 2703, Section 15; IEC 61730-2-10.17; UL 61730-2-10.17; IEC 62688-20.19; IEC 61730-2 10.18; IEC 61215-2 4.21; IEC 61215-4.5; UL 61215-2-4.5; IEC 61215-2; ANSI/UL 1703-19; ULC/ORD C1703-01-5.2; IEC 61730-2-10.15; UL 61730-2-10.15; ANSI/UL 3703-39--
mechanicalIEC 61215-4.1; UL 61215-2-4.1; IEC 61730-2-10.2; UL 61730-2-10.2; CAN/CSA-C22.2, No. 61730-2-10.1; IEC 61730-1-5.6.3; IEC 61730-2-10.6; UL 61730-2-10.6; IEC 61215-4.17; UL 61215-2-4.17; ANSI/UL 1703-42; ULC/ORD C1703-01-5.24; CAN/CSA-C22.2, No. 61730-2-10.10C; IEC 61730-2-10.26; UL 61730-2-10.26; ANSI/UL 1703- 38; ULC/ORD C1703-01-5.20; ANSI/UL 2703-20; IEC 61730-2-10.21; UL 61730-2-10.21; CAN/CSA-C22.2, No. 61730-2-10.10; ANSI/UL 1703-23; ULC/ORD C1703-01-5.6; UL 9703 24; ISO/IEC 17025:2017Photovoltaic Modules0.5 to 300 mm
mechanicalIEC 61730-2-10.22; UL 61730-2-10.22; IEC 61730-2-10.7; UL 61730-2-10.7; ANSI/UL 1703-41; ULC/ORD C1703-01-5.23; IEC 61215-4.16; UL 61215-2-4.16; ANSI/UL 2703-21; ANSI/UL 3703-47; IEC 61730-2-10.23; UL 61730-2-10.23; ANSI/UL 1703-24; ULC/ORD C1703-01-5.7; IEC 61730-2-10.10; UL 61730-2-10.10; CAN/CSA-C22.2, No. 61730-2-10.3; ANSI/UL 1703-22; ULC/ORD C1703-01-5.5; IEC 61215-4.14; UL 61215-2-4.14; IEC 61730-2-10.27; UL 61730-2-10.27; ANSI/UL 1703-29; ULC/ORD C1703-01-5.12; CAN/CSA-C22.2, No. 61730-2-10.10A; ANSI/UL 2703-14; ANSI/UL 3703-60; IEC 61215-2 4.22; ANSI/UL 2703-23; IEC 61730-2-10.32 MST-55; UL 61730-2-10.32; IEC 61215-4.13; UL 61215-2-4.13; IEC 61730-2-10.30; UL 61730-2-10.30; IEC 61730-2-10.33; UL 61730-2-10.33; ANSI/UL 1703-36; ULC/ORD C1703-01-5.18; IEC 61215-4.12; UL 61215-2-4.12; IEC 61730-2-10.29; UL 61730-2-10.29; ANSI/UL 2703-18; UL9703 36; IEC 61215-4.19 & 4.8; UL 61215-2-4.19 & 4.8; ANSI/UL 1703-35; ULC/ORD C1703-01-5.17; IEC 61215-4.11; UL 61215-2-4.11; ANSI/UL 2703-17; UL 9703 35; IEC 61730-2-10.28; UL 61730-2-10.28--
mechanical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

A2LA

ISO/IEC 17025

Active

921.02

View scope

Accredited scope, certificate 921.02

DisciplineMethodMatrixRange
materialsIEC 61215-4.10; UL 61215-2-4.10; IEC 61730-2-10.31; UL 61730-2-10.31; ANSI/UL 1703-33; ULC/ORD C1703-01-5.15; UL 9703 33; IEC 61215-4.4; UL 61215-2-4.4; ANSI/UL 790; ANSI/UL 1703, Sections 16 and 31; ULC/ORD C1703-01-5.14; ANSI/UL 2703, Section 15; IEC 61730-2-10.17; UL 61730-2-10.17; IEC 62688-20.19; IEC 61730-2 10.18; IEC 61215-2 4.21; IEC 61215-4.5; UL 61215-2-4.5; IEC 61215-2; ANSI/UL 1703-19; ULC/ORD C1703-01-5.2; IEC 61730-2-10.15; UL 61730-2-10.15; ANSI/UL 3703-39--
mechanicalIEC 61730-2-10.22; UL 61730-2-10.22; IEC 61730-2-10.7; UL 61730-2-10.7; ANSI/UL 1703-41; ULC/ORD C1703-01-5.23; IEC 61215-4.16; UL 61215-2-4.16; ANSI/UL 2703-21; ANSI/UL 3703-47; IEC 61730-2-10.23; UL 61730-2-10.23; ANSI/UL 1703-24; ULC/ORD C1703-01-5.7; IEC 61730-2-10.10; UL 61730-2-10.10; CAN/CSA-C22.2, No. 61730-2-10.3; ANSI/UL 1703-22; ULC/ORD C1703-01-5.5; IEC 61215-4.14; UL 61215-2-4.14; IEC 61730-2-10.27; UL 61730-2-10.27; ANSI/UL 1703-29; ULC/ORD C1703-01-5.12; CAN/CSA-C22.2, No. 61730-2-10.10A; ANSI/UL 2703-14; ANSI/UL 3703-60; IEC 61215-2 4.22; ANSI/UL 2703-23; IEC 61730-2-10.32 MST-55; UL 61730-2-10.32; IEC 61215-4.13; UL 61215-2-4.13; IEC 61730-2-10.30; UL 61730-2-10.30; IEC 61730-2-10.33; UL 61730-2-10.33; ANSI/UL 1703-36; ULC/ORD C1703-01-5.18; IEC 61215-4.12; UL 61215-2-4.12; IEC 61730-2-10.29; UL 61730-2-10.29; ANSI/UL 2703-18; UL9703 36; IEC 61215-4.19 & 4.8; UL 61215-2-4.19 & 4.8; ANSI/UL 1703-35; ULC/ORD C1703-01-5.17; IEC 61215-4.11; UL 61215-2-4.11; ANSI/UL 2703-17; UL 9703 35; IEC 61730-2-10.28; UL 61730-2-10.28--
mechanical---
mechanicalIEC 61215-4.1; UL 61215-2-4.1; IEC 61730-2-10.2; UL 61730-2-10.2; CAN/CSA-C22.2, No. 61730-2-10.1; IEC 61730-1-5.6.3; IEC 61730-2-10.6; UL 61730-2-10.6; IEC 61215-4.17; UL 61215-2-4.17; ANSI/UL 1703-42; ULC/ORD C1703-01-5.24; CAN/CSA-C22.2, No. 61730-2-10.10C; IEC 61730-2-10.26; UL 61730-2-10.26; ANSI/UL 1703- 38; ULC/ORD C1703-01-5.20; ANSI/UL 2703-20; IEC 61730-2-10.21; UL 61730-2-10.21; CAN/CSA-C22.2, No. 61730-2-10.10; ANSI/UL 1703-23; ULC/ORD C1703-01-5.6; UL 9703 24; ISO/IEC 17025:2017Photovoltaic Modules0.5 to 300 mm