Registers refreshed 2026-11-06.See refresh dates
Taiwan

SGS Taiwan Ltd. Chemical Laboratory - Kaohsiung

No. 61, Kai-Fa Road, Nanzih Dist., Kaohsiung, Taiwan, Kaohsiung, 81170, Republic of China Taiwan, Kaohsiung, Taiwan

Visit website
A2LA 7318.01ISO/IEC 17025Register refreshed 2026-11-06
Part of the SGS group: 169 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
20
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 20 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 62321 series6
IEC 62321-4
IEC 62321-5
IEC 62321-6
IEC 62321-7-1
IEC 62321-7-2
IEC 62321-8
EN5
EN 14582
EN 17130
EN 17137
EN 17681-1
EN 17681-2
EPA4
EPA 537.1
EPA 3535
EPA 3550Ultrasonic Extraction
EPA 8270Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)
ISO4
ISO 11936Leather - Determination of total content of certain bisphenols
ISO 16186Footwear - Critical substances potentially present in footwear and footwear components - Determination of dimethyl fumarate (DMFU)
ISO 21135Chemicals for the leather tanning industry - Determination of the total content of certain bisphenols
ISO 23702-1Leather - Per- and polyfluoroalkyl substances - Part 1: Determination of non-volatile compounds by extraction method using liquid chromatography
Other standards1
DIN 54232

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7318.01

The scope document we hold says it was valid until 2026-09-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 7318.01

LineMethodMatrixRange
1IEC 62321-6; GB/T 39560.6; CNS 15050; IEC 62321-8; GB/T 39560.8; SOP TESP-KE-198; TEGEWA method; IEC 62321-7-1; IEC 62321-7-2; GB/T 39560.701; GB/T 39560.702; IEC 62321-4; GB/T 39560.4; IEC 62321-5; GB/T 39560.5; EN 17681-1; EN 17681-2; ISO 23702-1; GB/T 29493.2; CNS 15808-1; CEN/TS 15968; US EPA 3550; US EPA 8270; US EPA 537.1plastics and polymers, rubber, leather, textiles, and footwear, electrical and electronic, metals, alloys, petroleum products, chemical formulations - solvents, cleaners, adhesives, paints, inks, dyes, pigments, auxiliaries and pretreatment agents, surfactants, coatings, paper, glass, ceramic, children's products (Toys), wastewater (incoming water, untreated wastewater, effluent), sludge, consumer products-
2ISO 11936; ISO 21135; US EPA 3550; US EPA 3535; EN 17137; DIN 54232; US EPA 8270; ISO 16186; EN 17130; CNS 15853-3; US EPA 3550; BS EN 14582--
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation. Accredited Laboratory A2LA has accredited SGS TAIWAN LTD. CHEMICAL LABORATORY - KAOHSIUNG Kaohsiung, Taiwan (R.O.C.) for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 22nd day of August 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7318.01 Valid to September 30, 2026 Revised July 15, 2025

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.