Registers refreshed 2026-11-08.See refresh dates
Taiwan

Worldwide Testing Services (Taiwan) Co.,

6F, No. 58, Lane 188, Ruey Kuang Road, Neihu District, Taipei City 114, Republic of China Taiwan, Taipei City 114, Taiwan

Visit website
A2LA 2732.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
73
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 73 standard numbers and the 32 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI41
ETSI EN 300 086
ETSI EN 300 113
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 390
ETSI EN 300 422-1
ETSI EN 300 422-2
Show all 41
ETSI EN 300 422-3
ETSI EN 300 440
ETSI EN 300 674-2-2
ETSI EN 301 357
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-9
ETSI EN 301 489-13
ETSI EN 301 489-15
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 783
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-4
ETSI EN 301 908-11
ETSI EN 301 908-15
ETSI EN 302 208
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 609
ETSI EN 303 687
ETSI TS 151 010-1
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+2 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

AS/NZS IEC 61000.3.2probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+2 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

AS/NZS IEC 61000.3.3probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

AS/NZS 61000.6.3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

AS/NZS 61000.6.4identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

CISPR9
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national

National versions in the same scope

AS CISPR 11national version with changes

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 13identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55013. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2, IEC 55014-2. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national

National versions in the same scope

AS CISPR 15national version with changes

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

IEC6
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61131-2
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)

Certificate says EN 62311. Probably the same standard; not checked against the EN document.

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
EN3
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50385
EN 50412-1
Other standards1
AS/NZS 2772.2

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

2732.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 2732.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; CISPR 11; EN 55011; AS/NZS CISPR 11; AS CISPR 11; CISPR 13; EN 55013; AS/NZS CISPR 13; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; EN IEC 55015; AS/NZS CISPR 15; AS CISPR 15; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; AS/NZS IEC 61000.3.2; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; AS/NZS IEC 61000.3.3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6--
2IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; EN 50130-4; EN 50412-1; CISPR 14-2; EN 55014-2; EN IEC 55014-2; IEC 61547; EN 61547; EN IEC 61547; CISPR 24; EN 55024; CISPR 35; EN 55035; IEC 61131-2; EN 61131-2; IEC 61326-1; EN 61326-1; EN IEC 61326-1; IEC 60601-1-2; EN 60601-1-2; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-9; EN 301 489-13; EN 301 489-15; EN 301 489-17; EN 301 489-19; EN 301 489-34; EN 301 489-50; EN 301 489-52; EN 300 220-1; EN 300 220-2; EN 300 220-4; EN 300 220-3-1; EN 300 220-3-2; EN 300 328; EN 301 893; EN 300 330; EN 300 440; EN 300 422-1; EN 300 422-2; EN 300 422-3; EN 301 357; EN 300 674-2-2; EN 300 086; EN 300 113; EN 301 783; EN 300 390; EN 302 208; EN 303 413; EN 303 417; EN 303 687; EN 50385; EN 62311; EN 62479-to 100 A/m
3EN 303 609; EN 301 511; 3GPP TS 25.106; TS 25.106; 3GPP TS 25.143; TS 25.143; 3GPP TS 51 010-1; TS 151 010-1; 3GPP TS 34.121; EN 301 908-01; EN 301 908-02; EN 301 908-04; EN 301 908-11; EN 301 908-15; AS/NZS 2772.2; AS/NZS 4268; AS/NZS 4365; AS/NZS 4768.1; AS/NZS 4768.2; AS/NZS 4771; CISPR 11; EN 55011; AS/NZS CISPR 11; AS CISPR 11; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; AS/NZS CISPR 15; AS CISPR 15; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; AS/NZS 61000.6.3; IEC 61000-6-4; EN 61000-6-4; AS/NZS 61000.6.4; AS 61000.6.4--
4CISPR 11; EN 55011; AS/NZS CISPR 11; AS CISPR 11; CISPR 14-1; EN 55014-1; EN IEC 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; AS/NZS CISPR 15; AS CISPR 15; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; ICES-003; ICES-005; VCCI CISPR 32; AS/NZS 4268; AS/NZS 4771; CISPR 13; EN 55013; AS/NZS CISPR 13; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3-to 40 GHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited Worldwide Testing Services (Taiwan) Co., Ltd. Taipei City, Taiwan for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of any additional program requirements in the Electrical field. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 24th day of March, 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2732.01 Valid to March 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.