Prescott Instruments
Unit F. Northway Lane Trading Estate, Northway Lane, Tewkesbury, Gloucester, GL20 8JH, United Kingdom, Gloucester, United Kingdom
Visit website- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM D1646
ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
ISO 7500-1Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system
ASTM D1646
BS ISO 7500-1; ASTM D2240; ISO-48-9
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active4023.01
The scope document we hold says it is valid until 2027-07-31.
Accredited scope, certificate 4023.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4023.01) Revised 02/25/2026 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PRESCOTT INSTRUMENTS LTD
Unit F, Northway Lane Trading Estate
Tewkesbury, Gloucester, GL20 8JH, UNITED KINGDOM
Ben Tarling Phone: 0 1684 274300, ext. 694
CALIBRATION
Valid To: July 31, 2027 Certificate Number: 4023.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 5:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Linear Encoder and
Indicator.
Heidenhain ND287
Up to 15 mm
(15 to 240) mm
(15 to 300) mm
0.06 %
0.02 %
0.03 %
Class A, B, C, D
II. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Dynamic Torque3
Measure
(1 to 80) dNm
0.18 dN·m
0.16 dN·m
0.49 dN·m
0.34 dN·m
0.28 dN·m
0.20 dN·m
0.23 °C
MDR calibration
MDR Tstd dynamic
ODR calibration
ODR Tstd dynamic
MMDR calibration
MMDR Tstd
Temperature meter | ||
| 2 | BS ISO 7500-1; ASTM D2240; ISO-48-9 | - | See scope document |
| 3 | ASTM D1646 | - | 0 to 100 Mooney |
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Unit F. Northway Lane Trading Estate, Northway Lane, Tewkesbury, Gloucester, GL20 8JH, United Kingdom, Gloucester, GB
51.86537, -2.24582
Open in MapsAccreditation data refreshed from the A2LA register on .