Pure Air Filtration
6700 Dawson Blvd, Building 3, 30093, Norcross, GA, United States
Visit website- Accredited standards
- 2
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM B825
ASTM D7385
ASTM B825-19; ANSI/ISA-71.04-2013; ASTM D 7385-07
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
2 lines
ISO/IEC 17025
Active7567.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 7567.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM B825-19; ANSI/ISA-71.04-2013; ASTM D 7385-07 | activated carbon pellets; alumina oxide beads; copper coated glass coupons; silver coated glass coupons | - |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
PURE AIR FILTRATION
Norcross, GA
for technical competence in the field of
Chemical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system (refer to
joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 2nd day of July 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7567.01
Valid to August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.