DNV Energy Systems Germany
Sommerdeich 14 b, 25709, Kaiser-Wilhelm-Koog, Germany
- Accredited standards
- 11
- DAKKS certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 11 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO5
ISO 1996-2Acoustics - Description, measurement and assessment of environmental noise - Part 2: Determination of sound pressure levels
ISO 3741Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for reverberation test rooms
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 3746Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
ISO 9613-2Acoustics - Attenuation of sound during propagation outdoors - Part 2: Engineering method for the prediction of sound pressure levels outdoors
DIN4
DIN 45635-1
DIN 45645-1
DIN 45680
DIN 45681
Other standards2
45688:2014
IEC 61400-11
IEC 61400-11; ISO 1996-2; BWEA 2008-02; DIN 45688:2014; TA Lärm 1968-07; VDI 2058 Part 1:1985-09; TA Lärm 1998-08
DIN EN ISO 3741; DIN EN ISO 3744; DIN EN ISO 3746; DIN 45635 -1; DIN 45645 -1; DIN 45680 + Beiblatt 1; DIN 45681; DIN ISO 9613 -2; FGW TR 1, Rev. 19
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-11134-01-00
Accredited scope, certificate D-PL-11134-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-11134-01-01
Accredited scope, certificate D-PL-11134-01-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | - | Measuring instrumentsShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-K-11134-03-00
Valid from : 27.05.2025
Date of issue : 27.05.2025 Page 2 of 3
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
Permanent Laboratory
C a l ib r at io n a n d M e as u re m e n t Ca p ab i l it ie s ( CM C)
Measurement
quantity / Calibration
item
Range Measurement
conditions /
procedure
Expanded
uncertainty of
measurement
Remarks
Electrical quantities
DC voltage
Measuring instruments
> 0 mV to 20 mV 33·10 -6 U + 1.9 µV U= measured value
> 20 mV to 200 mV 17 ·10 -6 U + 1.9 µV
> 0.2 V to 2 V 12 ·10 -6 U + 11 µV
> 2 V to 20 V 9.9 ·10 -6 U + 85 µV
> 20 V to 100 V 16 ·10 -6 U + 0.27 mV
> 100 V to 280 V 16 ·10 -6 U + 1 mV
> 280 V to 1050 V 23 ·10 -6 U + 4.3 mV
AC voltage
Measuring instruments
1 mV to 20 mV
15 Hz to 10 kHz
1.7 ·10 -3 U + 29 µV
> 20 mV to 200mV 0.4 ·10 -3 U + 44 µV
> 0.2 V to 2 V 0.19 ·10 -3 U + 0.11 mV
> 2 V to 20 V 0.19 ·10 -3 U + 0.81 mV
> 20 V to 100 V 0.21 ·10 -3 U + 5.8 mV
> 100 V to 280 V 0.21 ·10 -3 U + 12 mV
> 280 V to 1050 v 20 Hz to 1 kHz 0.33 ·10 -3 U + 63 mV
DC current
Measuring instruments
> 10 µA to 200 µA 0.23 ·10 -3 I + 24 nA I= measured value
> 0.2 mA to 2 mA 0.15 ·10 -3 I + 0.13 µA
> 2 mA to 20 mA 0.11 ·10 -3 I + 0.9 µA
> 20 mA to 200 mA 0.11 ·10 -3 I + 8.1 µA
> 0.2 A to 2 A 0.18 ·10 -3 I + 72 µA
> 2 A to 20.5 A 0.26 ·10 -3 I + 1.4 mA
AC current
Measuring instruments
10 µA to 200 µA 1.4 ·10 -3 I + 93 nA
> 0.2 mA to 2 mA 0.97 ·10 -3 I + 0.25 µA
> 2 mA to 20 mA 0.44 ·10 -3 I + 3 µA
> 20 mA to 200 mA 15 Hz to 1 kHz 0.46 ·10 -3 I + 25 µA
> 0.2 A to 2 A 0.55 ·10 -3 I + 0.12 mA
2 A to 20.5 A 0.85 ·10 -3 I + 5 mA | See scope document |
| 3 | - | Current transformersShow page textExtracted from the scope document; tables may not line up. View scope for the original. Annex to the Accreditation Certificate D-K-11134-03-00
Valid from : 27.05.2025
Date of issue : 27.05.2025 Page 3 of 3
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
Pe rmanent Laboratory
C a l ib r at io n a n d M e as u re m e n t Ca p ab i l it ie s ( CM C)
Measurement quantity
/ Calibration item
Range Measurement
conditions /
procedure
Expanded
uncertainty of
measurement
Remarks
Current ratio
Current transformers
10 A to 25 A (primary)
to 5 mA to 15 A (secondary)
to 25 mV to 15 V (secondary)
Comparison
measurement
50 Hz to 60 Hz
0.03 %
Measurement
uncertainty of
magnitude deviation,
related to the primary
quantity.
0.03 crad
Measurement
uncertainty of the
phase angle.
10 A to 100 A (primary)
to 50 mA to 1 A (secondary)
to 25 mV to 1 V (secondary)
Comparison
measurement
250 Hz to 9 kHz
0.05 %
Measurement
uncertainty of
magnitude deviation,
related to the primary
quantity.
0.19 crad
Measurement
uncertainty of the
phase angle.
> 25 A to 5 kA (primary)
to 5 mA to 15 A (secondary)
to 25 mV to 1 V (secondary)
Comparison
measurement
50 Hz; 60 Hz
0.03 %
Measurement
uncertainty of
magnitude deviation,
related to the primary
quantity.
0.03 crad
Measurement
uncertainty of the
phase angle.
> 5 kA to 10 kA (primary)
to 5 mA to 15 A (secondary)
to 25 mV to 15 V (secondary)
Comparison
measurement
50 Hz; 60 Hz
0.03 %
Measurement
uncertainty of
magnitude deviation,
related to the primary
quantity.
0.03 crad
Measurement
uncertainty of the
phase angle.
Abbreviations used:
CMC Calibration and measurement capabilities
DIN Deutsches Institut für Normung e.V. – German in stitute for standardization
EN Europäische Norm – European Standard
IEC International Electrotechnical Commission
ISO International Organization for Standardisation | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-11134-01-02
Accredited scope, certificate D-PL-11134-01-02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | DIN EN ISO 3741; DIN EN ISO 3744; DIN EN ISO 3746; DIN 45635 -1; DIN 45645 -1; DIN 45680 + Beiblatt 1; DIN 45681; DIN ISO 9613 -2; FGW TR 1, Rev. 19 | - | - |
| 3 | IEC 61400-11; ISO 1996-2; BWEA 2008-02; DIN 45688:2014; TA Lärm 1968-07; VDI 2058 Part 1:1985-09; TA Lärm 1998-08 | - | - |
| 4 | LAI | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.