Visional Technology,
Flexipark Free Zone Building A8, San Rafael de Alajuela, 20108, Costa Rica, San Rafael de Alajuela, Costa Rica
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 4111.02 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4111.02) 8/26/2025 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
VISIONAL TECHNOLOGY, SRL
Flexipark Free Zone Building A8
San Rafael de Alajuela, Costa Rica 20108
Victor Rivera Castro Phone: +506-4800-1845
CALIBRATION
Valid To: July 31, 2027 Certificate Number: 4111.02
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter/Equipment
Range CMC2, 4 (±) Comments
Vision Measurement System
and Multi-Sensors3
Length
Z-Axis Linear Error
(1D tactile)
EUV – Length Error of
Imaging Probe
Probing Error (PF2D)
Probing Error of the
Imagining Probe (PFV2D)
Up to 758 mm
Up to 177 mm
Up to 150 mm
Up to 3.5 mm
14 mm
Up to 3.5 mm
14 mm
(0.22 + 0.000 69L) μm
(0.29 + 0.0018L) μm
(1.0 + 0.0021L) μm
0.44 μm
1 μm
0.57 μm
1 μm
Glass line scale
Gage blocks
Glass line scale
Circle chart
Circle chart | to 758 mm |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4111.02) 8/26/2025 Page 2 of 5
Parameter/Equipment
Range CMC2, 4 (±) Comments
Coordinate Measuring
Machines (CMM)3
Length
Probe Performance
Scanning Performance
Up to 1000 mm
Up to 30 mm
Up to 30 mm
(0.14 + 0.0002L) μm
0.15 μm
0.12 μm
Step gage7
Sphere7
Sphere7
Universal Length Measuring
Machine (ULM/UMM)
Up to 12 inch
(2.0 + 0.91L) μin
Gage blocks, force
gage
Optical Comparator3, 8
Length (Horizontal)
Length (Vertical)
Chart Rotation
Up to 606 mm
Up to 24 in
Up to 192 mm
Up to 8 in
Up to 360°
(0.65 + 0.0019L) μm
(26 + 1.9L) μin
(1.7 + 0.003L) μm
(66 + 3L) μin
1.2 Arcminutes
Optical scale
Gage Blocks
Length
Parallelism
(Variation in Length)
(> 0.05 to 1) inch
(> 1 to 4) inch
(> 4 to 12) inch
(> 0.05 to 1) inch
(1.3 + 0.3L) μin
(1.1 + 0.5L) µin
(0.6 + 1.1L) µin
0.50 μin
Master gage
blocks (ULM)
Optical Scales, Reticules,
Grid / Dot Array
Length
Diameter
Angles
Up to 758 mm
Up to 3.5 mm
Up to 400 mm
Up to 360°
(0.52 + 0.000 67L) μm
0.41 μm
(2.1 + 0.0035D) μm
1.0 Arc minutes
Vision
measurement
system with
comparison to
calibrated
standards. | to 1000 mm |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4111.02) 8/26/2025 Page 3 of 5
Parameter/Equipment
Range CMC2, 4 (±) Comments
Length Standards
Up to 12 inch
Up to 758 mm
(2.0 + 0.91L) μin
(0.52 + 0.000 67L) μm
Labmaster universal
(ULM),
CMM, vision system
Micrometers
Up to 1 inch
(1 to 2) inch
(2.8 + 0.3L) µin
(14 + 1L ) µin
Gage blocks
Calipers
Up to 24 inch
(140 + 0.25L) µin
Gage blocks
Spheres
Size
Form
Up to 25 mm
Up to 25 mm
0.43 μm
0.13 μm
CMM with
comparison to
calibrated standard,
Labmaster Universal
(ULM)
Cylindrical Gages
Plain Pin and Plug Gages
Plain Ring Gages
Up to 4 inch
Up to 7 inch
4.0 μin
11 μin
Labmaster universal
(ULM), master gage
blocks
Thread Wires
(1 to 120) TPI
(0.2 to 10) Pitch
7.8 µin
0.20 µm
Labmaster universal
(ULM), master gage
blocks
Steel Rulers
Up to 640 mm
(3.9 + 0.0022L) μm
Vision measurement
system
Computer Tomography
Systems - CT Machines
Length Measurement Error
(E)
Sphere Distance Deviation
(SD)
Probing Error Size (PS)
Probing Error Form (PF)
Measuring volume
with a space of
diagonal < 205 mm
1.5 μm
0.8 μm
0.6 μm
0.9 μm
Sphere array
reference, master
sphere | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4111.02) 8/26/2025 Page 4 of 5
Parameter/Equipment
Range CMC2, 4 (±) Comments
Thread Plug Gages
Major Diameter
Pitch Diameter
Up to 2 inch
Up to 50.4 mm
(4 to 80) TPI
(0.2 to 10) mm Pitch
12 µin
0.38 µm
30 µin
0.75 µm
Labmaster universal
(ULM), Thread
Wires
II. Dimensional Testing1, 6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
1D Measurements
Up to 640 mm
(640 to 1000) mm
(2.0 + 0.0034L) μm
(2.9 + 0.0034L) µm
Vision measurement
system, ULM, CMM
2D Measurements
Diameter
Angles
Up to 400 mm
(400 to 700) mm
Up to 360°
(2.1 + 0.0035D) μm
(2.9 + 0.0034D) µm
(0.53 + 0.000 15A)
Arcminutes
Vision measurement
system, CMM
3D Measurements
Up to 900 mm
(2.9 + 0.0034L) µm
Vision measurement
system, CMM
___________________________________________
1
This laboratory offers commercial calibration service, field calibration service, and dimensional testing.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | to 2 inch |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4111.02) 8/26/2025 Page 5 of 5
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. , resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
millimeters (metric units) or inches (imperial units); D is the numerical value of the nominal diameter of
the device measured in millimeters (metric units) or inches (imperial units) ; and A is the nominal
numerical value of an angle measured in decimal degrees.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
7 Repeatability of the Unit Under Test has not been utilized in the calculation of the CMC value for this
measurement parameter. | ||
| 6 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.