Automated Precision
15000 John Hopkins Dr., 20850, Rockville, MD, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 2229.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | - | to 1 mm |
| 2 | sm 90 | - | to 80 m |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2229.01) 12/19/2024 Page 3 of 4
Parameter/Equipment
Range
CMC2 (±)
Comments
Spherically Mounted
Retro-Reflector (SMR)
Centering Accuracy
Up to 1 mm 3D Centering
Up to 1 mm X-Y Centering
Up to 1 mm Z-Depth Centering
0.25 µm
0.15 µm
0.20 µm
Straightness sensor
Spindle Analyzer
Up to 0.8 mm
0.06 µm
Trans. ref. laser
Straightness Sensor
Up to 3 mm
0.04 µm
Trans. ref. laser
Angle Sensor
Up to 800 arc seconds
0.07 arc seconds
Trans. ref. laser
XD Level Reference
Up to 1°
0.07 arc seconds
Trans. ref. laser
Swivel Check,
Roto Check
Angle Encoder: 360°
Level Sensor: 1.5°
0.11 arc seconds
0.17 arc seconds
Polygon mirror,
autocollimator,
angle encoder
Telescoping Ballbar
Up to 6 mm
0.06 µm
Trans. ref. laser
vProbe
Pitch: 80°
Yaw: 80°
Roll: 360°
0.94 µm/m
0.94 µm/m
1.1 µm/m
Laser tracking
system,
angle encoder
SmartTrack Sensor
Pitch: ± 55°
Yaw: ± 360°
Roll: ± 60°
1.5 arc seconds
Polygon mirror,
autocollimator, angle
encoder
Trans. Ref. Laser –
Wavelength
Distance
633 nm
Up to 80 m
0.004 parts in 10
6
0.1 μm/m
1
st ref. laser,
frequency counter,
1st ref. thermometer,
1st ref. pressure
sensor | to 1 mm |
| 4 | - | AirShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2229.01) 12/19/2024 Page 4 of 4
II. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Weather Station –
Temperature
Air Pressure
(-10 to 60) °C
(375 to 825) mmHg
0.07 °C
0.1 mmHg
1
st ref. thermometer
1st ref. pressure
sensor
____________________________________________
1 Commercial calibration service is not normally available for this laboratory.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 5 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - Washington D.C.Sterling, VA · ~23 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Electrical Test InstrumentsFrederick, MD · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Scale & EquipmentBaltimore, MD · ~65 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Baltimore, MDSparks, MD · ~66 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- InvoCalRixeyville, VA · ~91 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.