Registers refreshed 2026-11-08.See refresh dates
Finland

Nokia Solutions and Networks Oy, Type Approval

Finland

FINAS T297ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
54
FINAS certificate
1
Sites in our directory
2
FINAS accredited scope

What this lab is accredited for

Our reading of the FINAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 54 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI17
ETSI EN 300 019-2-1
ETSI EN 300 019-2-2
ETSI EN 300 019-2-3
ETSI EN 300 019-2-4
ETSI EN 301 489-1
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-50
ETSI EN 301 502
ETSI EN 301 908-1
ETSI EN 301 908-3
ETSI EN 301 908-14
Show all 17
ETSI EN 301 908-18
ETSI EN 301 908-23
ETSI EN 301 908-24
ETSI ES 202 336-12
ETSI ES 202 706-1
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Certificate says EN 61000-4-2. Probably the same standard; not checked against the EN document.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase

Certificate says EN 61000-4-11. Probably the same standard; not checked against the EN document.

IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60068 series9
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC5
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60950-22
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 62232
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
EN3
EN 50121-1
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50385
Other standards7
ANSI/TIA-603-E
AS/NZS 2772.2
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

FCC MP-5 (February 1986)
FCC PART 15Radio Frequency Devices
RSS-170

Read from the scope as published by FINAS. Register refreshed 2026-11-06.

Scope as published by FINAS

25 lines
FINAS

ISO/IEC 17025

Active

T297

View scope

Other Locations

1 other site in this organization

Accreditation data refreshed from the FINAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the FINAS entry linked above.