Registers refreshed 2026-11-08.See refresh dates
Italy

SNAM RETE GAS - LASVIL

Via Vezza D'Oglio, 6, 20139, Milano, Italy

Visit website
ACCREDIA 00248ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
6
ACCREDIA certificate
1
Sites in our directory
2
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
ISO 12039Stationary source emissions - Determination of the mass concentration of carbon monoxide, carbon dioxide and oxygen in flue gas - Performance characteristics of automated measuring systems

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.

Scope as published by ACCREDIA

1 line
ACCREDIA

ISO/IEC 17025

Active

00248

View scope

Accredited scope, certificate 00248

LineMethodMatrixRange
1UNI EN 14181:2015; UNI EN 12619:2013/EC1:2013; UNI EN 14792:2017; ISO 12039:2019 Annex A; UNI CEN/TS 17021:2017; UNI EN 15058:2017; UNI EN 14789:2017Stationary source emissions-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Vezza D'Oglio, 6, Milano, 20139, IT

45.44143, 9.20548

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.