Przedsiębiorstwo Wodociągów i Kanalizacji (Kalisz)
ul. Nad Prosną 28-34, 62-800, Kalisz, Poland
- Accredited standards
- 28
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 28 standard numbers and the 28 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO22
ISO 5664Water quality - Determination of ammonium - Distillation and titration method
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8288Water quality - Determination of cobalt, nickel, copper, zinc, cadmium and lead - Flame atomic absorption spectrometric methods
ISO 8467Water quality - Determination of permanganate index
Show all 22
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9964-1Water quality - Determination of sodium and potassium - Part 1: Determination of sodium by atomic absorption spectrometry
ISO 9964-2Water quality - Determination of sodium and potassium - Part 2: Determination of potassium by atomic absorption spectrometry
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN6
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1233Water quality - Determination of chromium - Atomic absorption spectrometric methods
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-ISO 9297:1994; PN-ISO 9964-2:1994+AK:1997; PN-ISO 9964-1:1994+AK:1997+Ap1:2009; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005; PN-EN 1233:2000; PN-ISO 8288:2002; PN-92/C-04570/01; PN-ISO 5664:2002
PN-EN 25663:2001; PN-73/C-04576/14; PN-EN 872:2007+Ap1:2007; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012 metoda C; PN-ISO 9964-1:1994 +Ap1:2009; PN-ISO 9964-2:1994; PN-ISO 6059:1999; PN-ISO 9297:1994; PN-EN ISO 8467:2001; PN-EN 27888:1999; PN-ISO 7150-1:2002; PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-92/C-04570/01
PN-ISO 8288:2002; PN-EN 26777:1999; PN-EN ISO 10523:2012; PN-EN ISO 10304-1:2009 +AC:2012; PN-EN 1622:2006; PN-EN 872:2007+Ap1:2007; PN-ISO 5667-10:2021-11
PN-EN ISO 19458:2007; PN-EN ISO 9308-2:2014-06; PN-EN ISO 9308-1:2014-12 + A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
5 lines
ISO/IEC 17025
ActiveAB 795
The scope document we hold says it is valid until 2027-04-19.
Accredited scope, certificate AB 795
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Waste waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 795
Scope of accreditation No. AB 795
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 795
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 23 z/of 03.12.2024 r.
p.o. KIEROWNIK A DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 795 z dnia 03.12.2019 r.
Cykl akredytacji od 23.03.2023 r. do 19.04.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 795 of 03.12.2019
Accreditation cycle from 23.03.2023 to 19.04.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 23, 03.12.2024 1/6
Nazwa i adres / Name and address
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.
ul. Nowy Świat 2a
62-800 Kalisz
LABORATORIUM
ul. Nad Prosną 28-34
62-800 Kalisz
Kod identyfikacyjny /
Identification code *)
Dziedzina i przedmiot badań / Field of testing and item:
- C/29/P, C/30/P,
- C/28
- K/29/P, K/28/P
- N/29/P, N/30/P
- N/28
- Q/29/P
- Badania chemiczne i pobieranie próbek ścieków, wody do spożycia przez ludzi / Chemical tests and
sampling of sewage, drinking water.
- Badania chemiczne wody / Chemical tests of water
- Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi / Microbiological tests
and sampling of water, drinking water.
- Badania właściwości fizycznych i pobieranie próbek ścieków, wody do spożycia przez ludzi / Tests of
physical properties and sampling of sewage, drinking water.
- Badania właściwości fizycznych wody / Tests of physical properties of water
- Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi / Sensory tests and sampling of
drinking water
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB-07, available at PCA website www.pca.gov.pl
AB 795 | - |
| 2 | PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-ISO 9297:1994; PN-ISO 9964-2:1994+AK:1997; PN-ISO 9964-1:1994+AK:1997+Ap1:2009; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005; PN-EN 1233:2000; PN-ISO 8288:2002; PN-92/C-04570/01; PN-ISO 5664:2002 | Waste water | See scope document |
| 3 | PN-EN 25663:2001; PN-73/C-04576/14; PN-EN 872:2007+Ap1:2007; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012 metoda C; PN-ISO 9964-1:1994 +Ap1:2009; PN-ISO 9964-2:1994; PN-ISO 6059:1999; PN-ISO 9297:1994; PN-EN ISO 8467:2001; PN-EN 27888:1999; PN-ISO 7150-1:2002; PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-92/C-04570/01 | Waste water | See scope document |
| 4 | PN-ISO 8288:2002; PN-EN 26777:1999; PN-EN ISO 10523:2012; PN-EN ISO 10304-1:2009 +AC:2012; PN-EN 1622:2006; PN-EN 872:2007+Ap1:2007; PN-ISO 5667-10:2021-11 | Drinking water | See scope document |
| 5 | PN-EN ISO 19458:2007; PN-EN ISO 9308-2:2014-06; PN-EN ISO 9308-1:2014-12 + A1:2017-04; PN-EN ISO 16266:2009; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004 | Drinking water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~177 kmPCAShares 4 accredited methods and materialsISO 5667-10:2021-11ISO 8288:2002Drinking water
- Laboratorium Badawcze INTERLABO A.Tomaszewski, M.Tomaszewski Spółka JawnaWarszawa · ~211 kmPCAShares 4 accredited methods and materialsEN 25663:2001ISO 5667-10:2021-11Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~248 kmPCAShares 4 accredited methods and materialsEN ISO 19458:2007ISO 5667-10:2021-11Drinking water
- AQUANET Laboratorium Spółka z o.o.Poznań · ~107 kmPCAShares 3 accredited methods and materialsEN ISO 19458:2007Drinking waterWaste water
- LabAnalitykaBrzeg Dolny · ~110 kmPCAShares 3 accredited methods and materialsISO 5667-10:2021-11Drinking waterWaste water
Accreditation data refreshed from the PCA register on .