Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Wessex Water Scientific Centre

Mead Lane, Saltford, BS31 3ER, Bristol, United Kingdom

Visit website
UKAS 0905ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
18
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 18 scope lines.

UKAS certificate 0905 · 18 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017Water-
2ISO/IEC 17025:2017Drinking water-
3ISO/IEC 17025:2017Drinking water-
4ISO/IEC 17025:2017Drinking water-
5ISO/IEC 17025:2017Water-
6ISO/IEC 17025:2017; The Drinking Water Testing Specification (DWTS); Method 4:502Water-
7ISO/IEC 17025:2017Water-
8ISO/IEC 17025:2017Water-
9ISO/IEC 17025:2017Drinking water-
10ISO/IEC 17025:2017Drinking water-
11ISO/IEC 17025:2017WaterSee scope document
12-Water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

0905 Accredited to ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wessex Water Scientific Centre Issue No: 088 Issue date: 04 July 2025 Testing performed by the Organisation at the locations specified Assessment Manager: DP1 Page 12 of 18 Materials/Products tested Type of test/Properties measured/Range of measurement Standard specifications/ Equipment/Techniques used Location Code WASTE WATERS (cont’d) Sampling Documented In-House Methods to meet the requirements of the Environment Agency MCERTS Performance Standard - sampling and chemical testing of untreated sewage, sewage effluent and trade effluent Treated Sewage Effluent Sampling for subsequent Documented in house method B (OSM) chemical testing using grab sampling technique On site measurement of Documented in house method B Temperature using calibrated thermocouple Trade Effluent Sampling for subsequent Documented in house method D (WTW effluent only Chemical testing using grab sampling technique On site measurement of Documented in house method D temperature Using calibrated thermocouple Trade Effluent to Controlled Measurement of Free and Method 9:114 by D Water (ground water derived Total Chlorine electrochemical measurement water treatment works using Kemio effluent only) Trade Effluent to Controlled Measurement of Total Method 9:114 by D Water (surface water derived Chlorine electrochemical measurement water treatment works using Kemio effluent only) END OF SECTION 2
-
13ISO/IEC 17025:2017Water-
14ISO/IEC 17025:2017Water-
15ISO/IEC 17025:2017Water-
16ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025:2017 Trade Effluent Manual or pumped spot Documented in-house method E sampling 6:101 On site measurement of pH Documented in-house method E 6:110; IEC 17025; in-house method EWater-
17ISO/IEC 17025:2017Water; OILS; oils-
18ISO/IEC 17025:2017; Mthd 2:804; Mthd 2:701; Mthd 2:815; Mthd 2:976; Mthd 3:525; Mthd 3:531; Microbiology of Sewage Sludge Part 3: 2024Water; OILS; oils-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Mead Lane, Saltford, Bristol, BS31 3ER, GB

51.41094, -2.44297

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.